RATIONALE: The efficiency of lubricants strongly depends on the content of functional additives. In order to assess the chemical and structural changes taking place in the lubricating oil and its additives during operation, it is essential to develop a method for simple and prompt analysis. METHODS: Two single additives as well as a fully formulated engine oil were analysed using an atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source coupled to a linear trap quadrupole Orbitrap XL hybrid tandem mass spectrometer and compared with results obtained by means of electrospray ionization (ESI) including additional low-energy collision-induced dissociation (LE-CID). The identification of additives directly from technical surfaces was simulated by using steel substrates as AP-MALDI targets with varying roughness. RESULTS: After assessment and selection of the most suited AP-MALDI matrix it was found that pure additives such as calcium sulfonate and zinc dialkyldithiophosphates (ZDDPs) could well be identified with abundant signal intensity based on their elemental composition. Molecular identification was corroborated by LE-CID in ESI mode. Additionally, additives present in the fully formulated commercial oil such as ZDDPs and salicylates could be reliably identified based on the elemental composition of the deprotonated molecules by means of the Orbitrap unit on different substrates including steel surfaces with high roughness. CONCLUSIONS: AP-MALDI is an efficient technique for determination of lubricant additives directly from commercial oil blends. Identification of additive components was also achieved on steel surfaces with high roughness as applied in tribological systems and thus it is expected that it will be possible to assess additive degradation in real applications, enabling more effective and timely maintenance measures.
RATIONALE: The efficiency of lubricants strongly depends on the content of functional additives. In order to assess the chemical and structural changes taking place in the lubricating oil and its additives during operation, it is essential to develop a method for simple and prompt analysis. METHODS: Two single additives as well as a fully formulated engine oil were analysed using an atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source coupled to a linear trap quadrupole Orbitrap XL hybrid tandem mass spectrometer and compared with results obtained by means of electrospray ionization (ESI) including additional low-energy collision-induced dissociation (LE-CID). The identification of additives directly from technical surfaces was simulated by using steel substrates as AP-MALDI targets with varying roughness. RESULTS: After assessment and selection of the most suited AP-MALDI matrix it was found that pure additives such as calcium sulfonate and zinc dialkyldithiophosphates (ZDDPs) could well be identified with abundant signal intensity based on their elemental composition. Molecular identification was corroborated by LE-CID in ESI mode. Additionally, additives present in the fully formulated commercial oil such as ZDDPs and salicylates could be reliably identified based on the elemental composition of the deprotonated molecules by means of the Orbitrap unit on different substrates including steel surfaces with high roughness. CONCLUSIONS: AP-MALDI is an efficient technique for determination of lubricant additives directly from commercial oil blends. Identification of additive components was also achieved on steel surfaces with high roughness as applied in tribological systems and thus it is expected that it will be possible to assess additive degradation in real applications, enabling more effective and timely maintenance measures.
Liquid lubricants consist of one or more base oils and up to around 25% v/v of functional additives. Their main tasks, among others, involve: improving the friction and wear performance between interacting surfaces; enabling the control of friction; serving as a coolant or heat transfer medium; increasing resistance against corrosion, oxidation and degradation by acids
,
; and to keep surfaces clean.
,There is a wide range of additives such as zinc dialkyldithiophosphates (ZDDPs), which are known for their anti‐wear, anti‐corrosion and anti‐oxidant functionality. Therefore, ZDDPs are often applied in engine lubricants as well as hydraulic and transmission oils.
Other relevant additives include overbased calcium sulfonates and salicylates which are widely used as broad‐spectrum detergents and anti‐wear additives. In addition, calcium sulfonates are known for their rust‐inhibiting and acid‐binding properties. In particular, overbased detergents are used as additives in engine oils to prevent the development of varnish and other deposits on hot metal surfaces and to neutralize the acid products formed during combustion.
,
,
,During sliding, a thin tribofilm can form on the rubbing surfaces, and this can reduce friction and wear in numerous cases. The composition of these tribofilms has been extensively investigated by various measurement techniques, such as X‐ray photoelectron spectroscopy (XPS),
,
,
,
,
X‐ray absorption spectroscopy,
,
,
and transmission electron microscopy (TEM) combined with focused ion beam (FIB) cutting.
Other available techniques include X‐ray absorption near edge structure (XANES),
,
RAMAN spectroscopy,
scanning electron microscopy (SEM) with energy‐dispersive X‐ray spectroscopy (EDS),
,
,
Fourier‐transform infrared (FTIR) spectroscopy,
,
electrospray ionization mass spectrometry (ESI‐MS),
,
high‐field asymmetric waveform ion mobility spectrometry coupled with mass spectrometry (FAIMS‐MS),
or dynamic time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS).Direct surface analysis techniques such as desorption electrospray ionization (DESI‐MS)
oil analysis and direct analysis in real time coupled with mass spectrometry (DART‐MS)
have been applied for quantitative analysis of a commercial lubricant antioxidant additive in a base oil, while mass spectrometric imaging (MSI) by means of laser desorption/ionization reflectron time‐of‐flight mass spectrometry (LDI‐RTOF‐MS) was used to analyse ex situ oil components applied as lubricant additives in a tribological layer of a tribologically stressed surface.
Another analytical technique employed for direct analysis of base oils and additives is the atmospheric solids analysis probe in conjunction with ion mobility mass spectrometry (ASAP‐IM‐MS).
,Atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) is complimentary to the previously mentioned analytical methods and already a powerful tool to analyse proteomes and lipidomes.
,
Moreover, this technique has also been already successfully adopted for characterization of lubricant oils to detect additives such as anti‐oxidants
and frictions modifiers
directly from base oil solutions as well as from tribologically stressed steel surfaces.
In addition, previous studies have used different surface materials as AP‐MALDI targets, with the gold‐coated steel target showing superior desorption/ionization yield.
,
,AP‐MALDI is an efficient analytical method because the time‐consuming and costly sample preparation necessary for other techniques is significantly reduced. Furthermore, for this method atmospheric pressure is present, thus avoiding excessive vaporization of volatile compounds. However, no comprehensive analysis has yet been carried out in a fully formulated engine oil by means of AP‐MALDI, neither on gold‐coated steel targets nor on other material surfaces of industrial interest, which would be a major step towards direct chemical analysis of tribofilms in wear tracks. In this study, a fully formulated SAE 0W‐20 engine oil and two pure additives, calcium sulfonate and ZDDP, were analysed with AP‐MALDI on gold‐coated steel targets and on AISI 52100 steel discs, a typical bearing material, with different roughnesses.
The AP‐MALDI target materials were varied to investigate differences in desorption/ionization abundances in order to simulate realistic surface conditions of industrial component samples.
EXPERIMENTAL
Chemicals and materials
In this study an engine oil and two separate additive components were used for AP‐MALDI measurements. The engine oil was a commercially available fully formulated SAE 0W‐20 engine oil with viscosity index 172 (dynamic viscosity 48 mm2/s (40°C) and 9 mm2/s (100°C)). A detailed overview and additional properties of the selected engine oil were provided by Besser et al.
The two additives, commercial zinc dialkyldithiophosphate (ZDDP, liquid, received pre‐dissolved in diluent oil and used as received) and calcium sulfonate (55% v/v mixture in mineral oil), were purchased from LLK‐Naftan (Vienna, Austria) and Rhein Chemie (Vienna, Austria), respectively. For AP‐MALDI‐MS experiments the following AP‐MALDI matrices were applied: sinapic acid (SA, ≥99,0%), 2,5‐dihydroxybenzoic acid (DHBA, ≥99,0% HPLC grade), α‐cyano‐4‐hydroxycinnamic acid (CHCA, ultra‐pure), purchased from Sigma‐Aldrich (Vienna, Austria), as well as dithranol (DTH, ≥ 98,0%, for MALDI), purchased from Fisher Scientific (Vienna, Austria). LC/MS grade solvents chloroform (≥ 99,9%, HPLC gradient grade), purchased from Honeywell (Vienna, Austria), and methanol (≥ 99,9%, HPLC gradient grade), purchased from Sigma‐Aldrich, were additionally used for sample preparation.A standard AP‐MALDI gold‐coated steel target (hereafter referred to as “gold target”) was used as surface reference material provided by MassTech (Columbia, MD, USA). AISI 52100 steel discs (hereafter referred to as “steel disc”) with a diameter of 2.5 cm were chosen as complementary AP‐MALDI target materials, in order to simulate realistic behavior on technical surfaces (e.g. in triboexperiments) as well as to investigate the influence of surface roughness on additive desorption/ionization abundances. The steel sample targets were surface ground to varying roughness values using metallographic methods (see Figure 1). The average surface roughness Ra of the samples was measured using a Leica DCM 3D‐confocal microscopy instrument (Leica Microsystems, Wetzlar, Germany). The resulting roughness values of applied target specimens are given in Figure 1.
FIGURE 1
Target specimens with varied surfaces roughness: (A), standard AP‐MALDI Au‐covered steel target (reference) Ra = 0.02 μm; and AISI 52100 steel discs (B) mirror‐polished, Ra < 0.01 μm; (C) low roughness, Ra = 0.06 μm; (D) high roughness, Ra = 0.130 μm [Color figure can be viewed at wileyonlinelibrary.com]
Target specimens with varied surfaces roughness: (A), standard AP‐MALDI Au‐covered steel target (reference) Ra = 0.02 μm; and AISI 52100 steel discs (B) mirror‐polished, Ra < 0.01 μm; (C) low roughness, Ra = 0.06 μm; (D) high roughness, Ra = 0.130 μm [Color figure can be viewed at wileyonlinelibrary.com]
AP‐MALDI‐MS experiments
The AP‐MALDI PDF+ ion source (MassTech, Columbia, MD, USA) on the LTQ Orbitrap XL hybrid tandem mass spectrometer was utilized for all AP‐MALDI‐MS experiments in the present study. All AP‐MALDI‐MS results were obtained with reduced mass resolution of m/Δm 30,000 at FWHM (full width at half maximum) to reduce analysis time of molecules within the mass analyser and increase the number of scan events due to the limited volume of available sample compared with ESI experiments and with mass accuracy better than 7 ppm. This allowed detection of the protonated and deprotonated molecules with chemical structures already known from ESI measurements. Detailed experimental parameters and results of correlating ESI‐MS measurements are given in the supporting information. The lubricant specimens were deposited on the surface of the selected AP‐MALDI target and irradiated with UV laser light pulses of the solid‐state Nd:YAG laser at a wavelength of 355 nm. The laser was operated in spiral motion mode (screened area ~2 mm2) at a repetition rate of 10 Hz. The pulse width was at 3–5 ns (FWHM). In this study a pulse energy of 40 μJ was used and, to optimize the signal intensity, the pulsed dynamic focusing (PDF) was set to 25 μs. For all AP‐MALDI‐MS experiments the automatic gain control of the LTQ Orbitrap XL was turned off in order to achieve an equal number of laser shots for all single scan events.
,
The injection time was set to 500 ms and total acquisition time per scan was set to 0.5 min.
Operating conditions were applied according to tuning optimization of parameters: (a) for negative ion mode: AP‐MALDI plate voltage, −2.6 kV; capillary temperature, 200°C; capillary voltage, −15 V; tube lens voltage‐120 V and (b) for positive ion mode: AP‐MALDI plate voltage, 3.5 kV; capillary temperature, 275°C; capillary voltage, 10 V; tube lens voltage 80 V.The AP‐MALDI matrices were each dissolved in a solution of 7:3 (v/v) chloroform/methanol at a concentration of 10 mg/mL. The pure additives and the engine oil were separately diluted in the same solvent to obtain a volume ratio of 1:10 (v/v). For all the AP‐MALDI‐MS measurements the ratio of sample to matrix
was 1:10 (v/v). Additional studies of the engine oil were performed at ratios of 1:30 and 1:50 (v/v) with DTH matrix only to assess whether the dilution factor of the matrix acts differently, e.g. increased ratio of analyte to matrix ions and signal‐to‐noise ratio. Droplets of 1.5 μL of the resulting solutions were deposited on the different targets and let dry at room temperature resulting in spot areas of ~12.5 mm2. Before each AP‐MALDI‐MS experiment, the target surfaces were thoroughly cleaned using methanol.
Microscopy analyses
Prior to and after AP‐MALDI‐MS measurements, optical microscopy was performed on the dried sample spots of fully formulated SAE 0W‐20 engine oil with DTH matrix deposited on gold and steel targets, making use of a AXIO Imager M2m reflected light microscope (Carl Zeiss Microscopy, Jena, Germany) in bright field mode. Selected AP‐MALDI spots from the above sample were analysed further with environmental scanning electron microscopy (ESEM) using a JSM IT300 microscope (JEOL, Tokyo, Japan) with an accelerating voltage of 15 kV in back‐scattered electrons (BSE) mode. To avoid evaporation or decomposition and charging effects of the analysed compounds, they were analysed in low vacuum and the pressure during ESEM measurements was set to 50 Pa.
RESULTS AND DISCUSSION
Evaluation of peak abundances depending on matrix/analyte crystal structure and distribution
For AP‐MALDI‐MS measurements, the analyte/matrix solutions of fully formulated SAE 0W‐20 engine oil and DTH matrix were spotted on the gold target. For all samples, it was obvious that the evaporation of chloroform and methanol occurred asynchronously, resulting in an inhomogeneous distribution of the matrix and thus inhomogeneous crystal formation, density and sizes (see Figure 2A). Hence, the signal response from areas with differently shaped matrix/analyte crystals was examined performing six AP‐MALDI‐MS scan events on each spot. The light microscopic images compared with the AP‐MALDI‐MS results indicate that measurements are to be performed at areas where the crystals were visibly larger (see Figure 2B), compared with other areas with denser but very small crystals. Only at these positions could the desired peaks be detected with sufficient signal intensity. Comparable results were obtained on all investigated AP‐MALDI target surfaces used for this study. Additionally, ESEM was applied (see Figure 2C) to compare crystal manifestations and shapes. The larger crystal accumulations have been observed to form perpendicularly to the considered target surface and to form a pronounced 3D‐contour (see Figure 2D).
FIGURE 2
Overview of a matrix/analyte solution spotted on a gold target (fully formulated SAE 0W‐20 engine oil and DTH matrix): (A), light microscope overview and (B), detail as well as (C), ESEM overview and (D), enlarged detail [Color figure can be viewed at wileyonlinelibrary.com]
Overview of a matrix/analyte solution spotted on a gold target (fully formulated SAE 0W‐20 engine oil and DTH matrix): (A), light microscope overview and (B), detail as well as (C), ESEM overview and (D), enlarged detail [Color figure can be viewed at wileyonlinelibrary.com]
Identification of additive components from reference target
In this study, pure commercial ZDDP and calcium sulfonate in base oil were diluted separately to obtain concentrations of 1:10 (v/v) and were measured in negative ion AP‐MALDI mode. Since the maximum ion abundances of the detected protonated and deprotonated molecule peaks with AP‐MALDI‐MS was 104 it was difficult to perform LE‐CID fragmentation of the precursor ions. Therefore, to confirm the types of molecules of the additive components the elemental compositions obtained by means of AP‐MALDI were correlated to ESI results. Four different matrices (DTH, CHCA, 2,5‐DHBA and SA) were separately mixed with the above‐mentioned pure additive components as well as the fully formulated engine oil in a sample/matrix ratio of 1:10 (v/v) and applied on a standard gold‐coated steel AP‐MALDI target for MS examinations in negative and positive ion mode.In addition to the peaks observed in ESI‐MS in negative ion mode, abundant peaks of matrix [Ma‐H]− (Ma, matrix molecule) and matrix cluster ions [2Ma−H]− were detected as well. [Ma−H]− and [2Ma−H]− ions were observed for DTH at m/z 225.0542 and 449.1004, for CHCA at m/z 188.0343 and 377.0757, for 2,5‐DHBA at m/z 152.0108 and 307.0440, and for SA at m/z 223.0597 and 447.1270, respectively. Moreover, matrix ions [Ma+H]+ and matrix cluster ions [2Ma+H]+ were also determined in AP‐MALDI positive ion mode for matrix compounds DTH (m/z 227.0708 and 451.1188), CHCA (m/z 190.0502 and 379.0932), 2,5‐DHBA (m/z 155.0329), as well as SA (m/z 225.0743 and 449.1416).AP‐MALDI‐MS was applied in negative ion mode for calcium sulfonates. All deprotonated molecules of the calcium sulfonate additive found in ESI‐MS were also detected in AP‐MALDI‐MS for all four applied matrix compounds. However, with DTH as matrix, ion abundances at least a factor of 10 higher were found for the desired deprotonated molecules. Measurements of the sulfonate ions detected by AP‐MALDI at m/z 451.3225 (C21), 465.3381 (C22), 479.3537 (C23), 493.3694 (C24), 507.3850 (C25), 521.4004 (C26), and 535.4161 (C27) yielded the same m/z values within the instrument accuracy compared with ESI results (see Figure 3A and supporting information).
FIGURE 3
AP‐MALDI mass spectra in negative ion mode of pure additive samples with DTH matrix applied: (A), calcium sulfonates and (B), ZDDP (dashed line: dithiophosphates; solid line: O,O‐phosphorothioates). For demonstration of the AP‐MALDI mass spectra, results obtained with DTH matrix were selected due to most abundant signal response
AP‐MALDI mass spectra in negative ion mode of pure additive samples with DTH matrix applied: (A), calcium sulfonates and (B), ZDDP (dashed line: dithiophosphates; solid line: O,O‐phosphorothioates). For demonstration of the AP‐MALDI mass spectra, results obtained with DTH matrix were selected due to most abundant signal responseFor ZDDP, similar results were observed compared with calcium sulfonate, where the DTH matrix yielded higher ion abundances, too. The deprotonated ZDDP fragment ions dithiophosphates with m/z values of 241.0488 (C4‐C4), 297.1096 (C4‐C8), and 353.1719 (C8‐C8) and the O,O‐phosphorothioates with m/z 281.1325 (C4‐C8) and 337.1948 (C8‐C8), observed already in ESI‐MS measurements (see supporting information), were also detected with AP‐MALDI (see Figure 3B).The detected matrix ions and matrix cluster ions exceeded the abundances of the additive peaks. Using DTH matrix solution, for both additives the ion abundances of representative additive peaks were increased by a factor of 10 compared with the other matrices applied. The results were comparable for all detected additive peaks. Maximum ion abundances of representative peaks selected for both additives are given in Table 1. The total ion count (TIC) for ESI experiments exceeded AP‐MALDI values and usually was in the range of 107 to 108 ions and, thus, at least 103 times higher. Measurements performed with AP‐MALDI‐MS could lead to complex mass spectra due to the presence of matrix peaks. However, the high resolving power of the Orbitrap mass analyser allowed the detection of additive peaks with known m/z values with the drawback of lower ion abundances in comparison with ESI‐MS.
TABLE 1
Maximum AP‐MALDI‐MS ion abundances of representative deprotonated molecules of calcium sulfonate (m/z 493.3694) and dithiophosphate (m/z 353.1719) in negative ion mode
Applied matrix component
Ca‐sulfonate m/z 493.3694
Dithiophosphate m/z 353.1719
DTH
3.7 × 104
5.0 × 104
CHCA
2.6 × 103
3.7 × 103
2,5‐DHBA
1.0 × 103
6.9 × 102
SA
1.9 × 103
3.4 × 103
Maximum AP‐MALDI‐MS ion abundances of representative deprotonated molecules of calcium sulfonate (m/z 493.3694) and dithiophosphate (m/z 353.1719) in negative ion modeThe calcium sulfonate additive sample was analysed in positive ion mode with AP‐MALDI using all four matrices. However, due to very low ion abundances no additive or adduct peaks could be detected.
Identification of commercial engine oil components from reference target
Further analyses were performed for the fully formulated SAE 0W‐20 engine oil in negative and positive ion mode with all four matrices DTH, SA, CHCA and 2,5‐DHBA. Analysis of the engine oil SAE 0W‐20 by means of AP‐MALDI in negative ion mode with DTH matrix applied exhibited the additive ZDDP including the variety of alkyl chain lengths: dibutyl dithiophosphate (m/z 241.0487), dihexyl dithiophosphate (m/z 297.1098), dioctyl dithiophosphate (m/z 353.1723), as well as the salicylate detergents (m/z 333.2414 (C14); m/z 361.2727 (C16); m/z 389.3040 (C18)) (see Figure 4A). The m/z values and chemical structures of components identified are listed in Table 2. Similar to the previous analysis of the single additive components, the ion abundances of the investigated signals in the AP‐MALDI‐MS spectra were 103 to 104 times lower than the corresponding peaks detected by ESI‐MS (cf. Table 3). The obtained AP‐MALDI‐MS results allowed determination of the elemental composition and corresponded to the ions detected in ESI mode. Furthermore, it was observed in both methods (ESI and AP‐MALDI) that ZDDP fragment ions of residual impurities with shorter alkyl chain length showed higher ion abundances.
FIGURE 4
Mass spectra obtained by AP‐MALDI‐MS of engine oil SAE 0W‐20 obtained (A), in negative ion mode with DTH matrix applied (dashed line: dithiophosphates; solid line: salicylates) and (B), in positive ion mode with CHCA matrix applied (dashed line: diphenylamines; solid line: amine ethyl esters)
TABLE 2
Measured m/z values and chemical structures of components identified in the engine oil SAE 0W‐20 obtained by means of ESI‐MS and AP‐MALDI‐MS in negative ion mode including deviations of the measured m/z values
Name
Molecular formula
Chemical structure
Nominal value (m/z)
ESI (m/z)
ΔM/M (ppm)
AP‐MALDI (m/z)
ΔM/M (ppm)
Dialkyl dithiophosphates
C8H18O2PS2−
chemical structure image
241.0491
241.0483
3.3
241.0487
1.7
C12H26O2PS2−
chemical structure image
297.1117
297.1104
4.4
297.1098
6.4
C16H34O2PS2−
chemical structure image
353.1743
353.1728
4.2
353.1723
5.7
Salicylates
C21H33O3−
chemical structure image
333.2435
333.2421
4.2
333.2414
6.3
C23H37O3−
chemical structure image
361.2748
361.2733
4.2
361.2727
5.8
C25H41O3−
chemical structure image
389.3061
389.3045
4.1
389.3040
5.4
TABLE 3
Maximum AP‐MALDI ion abundances of representative ZDDP (m/z 241.0487) and salicylate (m/z 361.2727) additive deprotonated molecules detected in SAE 0W‐20 samples in negative ion mode
Matrix component applied
ZDDP m/z 241.0487
Salicylate m/z 361.2727
DTH
6.1 × 103
3.6 × 103
CHCA
‐
‐
2,5‐DHBA
4.8 × 101
3.5 × 101
SA
1.1 × 102
3.7 × 102
Mass spectra obtained by AP‐MALDI‐MS of engine oil SAE 0W‐20 obtained (A), in negative ion mode with DTH matrix applied (dashed line: dithiophosphates; solid line: salicylates) and (B), in positive ion mode with CHCA matrix applied (dashed line: diphenylamines; solid line: amine ethyl esters)Measured m/z values and chemical structures of components identified in the engine oil SAE 0W‐20 obtained by means of ESI‐MS and AP‐MALDI‐MS in negative ion mode including deviations of the measured m/z valuesMaximum AP‐MALDI ion abundances of representative ZDDP (m/z 241.0487) and salicylate (m/z 361.2727) additive deprotonated molecules detected in SAE 0W‐20 samples in negative ion modeWhen SA matrix was applied, only the detergent (salicylate) molecules could be detected. Ion abundances were observed a factor of 10 lower, compared with the use of DTH matrix. The desired peaks were not detected with CHCA nor with 2,5‐DHBA matrix. However, peaks of all matrices [Ma−H]− and matrix cluster ions [2Ma−H]− were observed. The sample/matrix ratio was set to 1:10 (v/v) for all AP‐MALDI‐MS measurements, as it was shown that for ratios 1:30 and 1:50 (v/v) with higher matrix concentrations, the molecular peaks investigated were suppressed and yielded lower signal intensities or could not be detected at all. For further investigations in the negative ion mode on steel targets, only DTH was used as matrix with the above‐mentioned sample/matrix ratio.Using AP‐MALDI‐MS in positive ion mode with CHCA and DTH as matrices for the engine oil the corresponding aminic anti‐oxidants nonyldiphenylamine (m/z 296.2381), dinonyldiphenylamine (m/z 422.3786) and nonadecyldiphenylamine (m/z 436.3951) as well as the fatty amine friction modifier 2‐[bis(2‐hydroxyethyl)amino] ethyl esters at m/z 388.3429 (C16:0) and 414.3585 (C18:1) were detected. The obtained mass spectra of the additive ions are given in Figure 4B. The structures of found additive molecules are shown in Table 4. For both applied matrices the ion abundances of similar peaks had the same order of magnitude. As previously observed, compared with ESI experiments, the ion abundances of obtained peaks in the AP‐MALDI mass spectra again were around 103 times lower. Ion abundances are given in Table 5.
TABLE 4
Measured m/z values of and chemical structures of components identified in the engine oil SAE 0W‐20 obtained by means of ESI‐MS and AP‐MALDI‐MS in positive ion mode including deviations of the measured m/z values
Name
Molecular formula
Chemical structure
Nominal value (m/z)
ESI (m/z)
ΔM/M (ppm)
AP‐MALDI (m/z)
ΔM/M (ppm)
Diphenylamines
C21H30N+
chemical structure image
296.2373
296.2367
2.0
296.2381
2.7
C30H48N+
chemical structure image
422.3781
422.3772
2.1
422.3786
1.2
C31H50N+
chemical structure image
436.3938
436.3929
2.1
436.3951
3.0
Aminic ethyl esters
C22H46O4N+
chemical structure image
388.3421
388.3413
2.1
388.3429
2.1
C24H48O4N+
chemical structure image
414.3578
414.3571
1.7
414.3585
1.7
TABLE 5
Main ion abundances of representative aminic anti‐oxidant (m/z 388.3429) and fatty amine friction modifier (m/z 414.3585) protonated molecules detected in commercial engine oil SAE 0W‐20 by means of AP‐MALDI‐MS in positive ion mode
Applied matrix component
Anti‐oxidant m/z 388.3429
Friction modifier m/z 414.3585
DTH
1.3 × 104
1.8 × 104
CHCA
6.2 × 104
7.3 × 104
Measured m/z values of and chemical structures of components identified in the engine oil SAE 0W‐20 obtained by means of ESI‐MS and AP‐MALDI‐MS in positive ion mode including deviations of the measured m/z valuesMain ion abundances of representative aminic anti‐oxidant (m/z 388.3429) and fatty amine friction modifier (m/z 414.3585) protonated molecules detected in commercial engine oil SAE 0W‐20 by means of AP‐MALDI‐MS in positive ion modeIn the case of the matrices SA and 2,5‐DHBA, the AP‐MALDI analysis of the engine oil did not enable the detection of the anti‐oxidant and friction modifier additives. DTH and CHCA could be used for the analysis of the fully formulated commercial oil samples in AP‐MALDI‐MS in positive ion mode. The peak abundances of the ions corresponding to the CHCA matrix applied were lower and more suppressed compared with the DTH matrix peaks. In addition, the analyte ions seem to be better desorbed/ionized with CHCA as a higher ion abundance was observed. This facilitated the observation of the expected peaks of the oil additives and CHCA was used as the preferred matrix for this analysis.
Identification of additive components from steel targets
AP‐MALDI‐MS measurements of the single ZDDP additive component were performed on the gold‐coated steel target. The resulting mass spectra were used as a reference due to their good consistency with ESI results and the obtained high ion abundances. Subsequently, three steel AP‐MALDI targets with different surface roughness (cf. Figure 1) were applied. In Figure 5A the abundances of the main ZDDP peaks of the AP‐MALDI‐MS measurement in negative ion mode on the four different target materials are given. Additional representative images of spots on all four surface modifications are given in the supporting information, including interpretations and comparisons with other AP‐MALDI studies.
FIGURE 5
Comparison of AP‐MALDI‐MS ion abundances obtained from various target surfaces in negative ion mode for (A), ZDDP and (B), Ca‐sulfonate additives' deprotonated molecule peaks. The ion abundances obtained from the gold target are given on the left y‐axis, whereas results from all other target surfaces are given on the right y‐axis
Comparison of AP‐MALDI‐MS ion abundances obtained from various target surfaces in negative ion mode for (A), ZDDP and (B), Ca‐sulfonate additives' deprotonated molecule peaks. The ion abundances obtained from the gold target are given on the left y‐axis, whereas results from all other target surfaces are given on the right y‐axisSimilar AP‐MALDI‐MS measurements were performed for Ca‐sulfonate additive components (see Figure 5B). In the diagrams, it can be seen that the abundances measured on steel targets were roughly 80% (ZDDP) and 90% (Ca‐sulfonate) lower than the results obtained with the reference gold target. However, since the measured m/z values were retrieved by means of high accuracy Orbitrap mass detection, it could be assumed that identification of deprotonated additive molecules was successful for all considered surface conditions of the different steel targets. Furthermore, both additives were associated with higher ion abundances on the polished steel target than on both steel targets with higher surface roughness.
Identification of engine oil components from steel targets
Following the AP‐MALDI‐MS analysis and successful identification of single additive components, subsequently, the fully formulated SAE 0W‐20 lubricant was analysed. This analysis was carried out in negative ion mode with DTH as matrix in a similar way on all four different target samples. Similar to previous measurements of the single additive components, it could be observed that on the steel targets the abundance of the main peaks was significantly lower compared with measurements on the gold target. It was however hardly possible to distinguish between the different qualities of the steel target surfaces. The corresponding results can be seen in Figure 6. The ion abundances of the desired molecules on the gold target were at least a factor of 10 higher than the corresponding peaks on the steel targets. However, this analysis of the commercial engine oil shows that the additive components ZDDP and salicylates could be very well identified through AP‐MALDI‐MS with high‐resolution detection also on steel target surfaces with higher roughness. This indicated a good applicability of this analytical method also under realistic industrial surface conditions (e.g. quality control laboratory).
FIGURE 6
Comparison of AP‐MALDI‐MS ion abundances of SAE 0W‐20 additive components obtained from various target surfaces in negative ion mode. The ion abundances obtained from the gold target are given on the left y‐axis, whereas results from all other target surfaces are given on the right y‐axis (triangle, rhombus: ZDDP; circle, square: salicylate)
Comparison of AP‐MALDI‐MS ion abundances of SAE 0W‐20 additive components obtained from various target surfaces in negative ion mode. The ion abundances obtained from the gold target are given on the left y‐axis, whereas results from all other target surfaces are given on the right y‐axis (triangle, rhombus: ZDDP; circle, square: salicylate)
CONCLUSIONS
In this study AP‐MALDI ion generation coupled with an Orbitrap mass analyser was used to successfully perform a direct analysis of the calcium sulfonate and ZDDP additives as well as of fully formulated commercial SAE 0W‐20 engine oil lubricant (containing ZDDP) in positive and negative ion mode. In order to confirm the detected chemical structures, the elemental compositions of the ions of interest were used combined with the results from ESI‐MS and LE‐CID‐fragmentation technique, as provided in the supporting information.AP‐MALDI‐MS experiments were performed on a gold target to evaluate the behavior and interactions of various matrix substances with the analyte ions. Results showed that DTH was the most suitable matrix for the assessment of the applied lubricant components in negative ion mode and CHCA for analysis in positive ion mode.Additionally, the fully formulated SAE 0W‐20 engine oil and the additives calcium sulfonate and ZDDP were analysed on steel discs with different surface roughness (as found in tribological experimental setups) by means of high ‐resolution and high‐accuracy AP‐MALDI‐MS. All examined lubricant components could be detected and identified on the more technical surfaces very well, which demonstrates a good applicability of this technique also for realistic industrial surface conditions. However, it was found that increasing surface roughness of the target material resulted in a decrease in the measured peak abundance. In general, the measured peak abundance of all detected analyte ions on all steel targets was significantly lower compared with measurements on the reference AP‐MALDI gold target.Thus, it was shown that this method is very suitable for quick and reliable detection and identification of lubricant components directly from oil blends without the necessity for additional prior separation steps. In the so‐called “soft” ionization process of AP‐MALDI a substantially higher number of small molecules with varying polarity becomes accessible for characterization compared with other methods such as ESI (e.g. due to the high number of background ions in the low m/z region, mainly molecules with high polarity are generated). Additional elucidation of tribological processes and characterization of degradation products and additive residues in used lubricants will be the subject of further investigations.
PEER REVIEW
The peer review history for this article is available at https://publons.com/publon/10.1002/rcm.9271.Figure S1 ESI mass spectra of pure additive samples: calcium sulfonate in negative (a) and positive (b) ion mode; c) ZDDP in negative ion mode (dashed line: dithiophosphates; solid line: O,O‐phosphorothioates).Figure S2 Relative ion abundances of engine oil SAE 0 W‐20 obtained by ESI‐MS in a) negative (dashed line: dithiophosphates; solid line: salicylates) and b) positive ion mode (dashed line: diphenylamines; solid line: aminic ethyl esters).Figure S3 ESI LE‐CID mass spectra of dithiophosphate in negative ion modeFigure S4 ESI LE‐CID mass spectra of calcium sulfonate in positive ion modeFigure S5 ESI LE‐CID mass spectra of diphenylamine in positive ion modeFigure S6 Isotopic distribution of dithiophosphateFigure S7 Isotopic distribution of calcium sulfonateFigure S8 Isotopic distribution of diphenylamineFigure S9 Isotopic distribution of calcium sulfonateFigure S10 Selected images of representative spots (engine oil SAE 0 W‐20, DTH) on the reference gold target, and all three steel targets with varying surface roughness.Table S1 ESI‐MS, negative ion mode: Calcium SulfonateTable S2 ESI‐MS, positive ion mode: Calcium SulfonateTable S3 ESI‐MS, negative ion mode: ZDDPTable S4 ESI‐MS, negative ion mode: SAE 0 W‐20 engine oilTable S5 ESI‐MS, positive ion mode: Aminic antioxidantsTable S6 AP‐MALDI‐MS, negative ion mode: MatricesTable S7 AP‐MALDI‐MS, positive ion mode: MatricesTable S8 AP‐MALDI‐MS, negative ion mode, matrix: DTH: Calcium Sulfonates, ZDDP additivesTable S9 AP‐MALDI‐MS, negative ion mode, matrix: DTH: SAE 0 W‐20 engine oilTable S10 AP‐MALDI‐MS, positive ion mode, matrix: CHCA: SAE 0W‐20 engine oilClick here for additional data file.