Literature DB >> 16604520

Comparison of CID spectra of singly charged polypeptide antibiotic precursor ions obtained by positive-ion vacuum MALDI IT/RTOF and TOF/RTOF, AP-MALDI-IT and ESI-IT mass spectrometry.

Ernst Pittenauer1, Martin Zehl, Omar Belgacem, Emmanuel Raptakis, Robert Mistrik, Günter Allmaier.   

Abstract

Various classes of polypeptide antibiotics, including blocked linear peptides (gramicidin D), side-chain-cyclized peptides (bacitracin, viomycin, capreomycin), side-chain-cyclized depsipeptides (virginiamycin S), real cyclic peptides (tyrocidin, gramcidin S) and side-chain-cyclized lipopeptides (polymyxin B and E, amfomycin), were investigated by low-energy collision induced dissociation (LE-CID) as well as high-energy CID (HE-CID). Ion trap (IT) based instruments with different desorption/ionization techniques such as electrospray ionization (ESI), atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) and vacuum MALDI (vMALDI) as well as a vMALDI-time-of-flight (TOF)/curved field-reflectron instrument fitted with a gas collision cell were used. For optimum comparability of data from different IT instruments, the CID conditions were standardized and only singly charged precursor ions were considered. Additionally, HE-CID data obtained from the TOF-based instrument were acquired and compared with LE-CID data from ITs. Major differences between trap-based and TOF-based CID data are that the latter data set lacks abundant additional loss of small neutrals (e.g. ammonia, water) but contains product ions down to the immonium-ion-type region, thereby allowing the detection of even single amino-acid (even unusual amino acids) substitutions. For several polypeptide antibiotics, mass spectrometric as well as tandem mass spectrometric data are shown and discussed for the first time, and some yet undescribed minor components are also reported. De novo sequencing of unusually linked minor components of (e.g. cyclic) polypeptides is practically impossible without knowledge of the exact structure and fragmentation behavior of the major components. Finally, the described standardized CID condition constitutes a basic prerequisite for creating a searchable, annotated MS(n)-database of bioactive compounds. The applied desorption/ionization techniques showed no significant influence on the type of product ions (neglecting relative abundances of product ions formed) observed, and therefore the type of analyzer connected with the CID process mainly determines the type of fragment ions. Copyright (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16604520     DOI: 10.1002/jms.1032

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  7 in total

Review 1.  Molecular mass spectrometry imaging in biomedical and life science research.

Authors:  Jaroslav Pól; Martin Strohalm; Vladimír Havlíček; Michael Volný
Journal:  Histochem Cell Biol       Date:  2010-10-28       Impact factor: 4.304

2.  CYCLONE--a utility for de novo sequencing of microbial cyclic peptides.

Authors:  Daniel Kavan; Marek Kuzma; Karel Lemr; Kevin A Schug; Vladimir Havlicek
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-24       Impact factor: 3.109

3.  Tissue transglutaminase-mediated glutamine deamidation of beta-amyloid peptide increases peptide solubility, whereas enzymatic cross-linking and peptide fragmentation may serve as molecular triggers for rapid peptide aggregation.

Authors:  Adrien W Schmid; Enrico Condemi; Gabriele Tuchscherer; Diego Chiappe; Manfred Mutter; Horst Vogel; Marc Moniatte; Yury O Tsybin
Journal:  J Biol Chem       Date:  2011-02-07       Impact factor: 5.157

4.  An Electrospray Ionization Mass Spectrometry Study on the "In Vacuo" Hetero-Oligomers Formed by the Antimicrobial Peptides, Surfactin and Gramicidin S.

Authors:  Marina Rautenbach; N Maré Vlok; Hans A Eyéghé-Bickong; Marthinus J van der Merwe; Marietjie A Stander
Journal:  J Am Soc Mass Spectrom       Date:  2017-05-30       Impact factor: 3.109

5.  Investigations into viomycin biosynthesis by using heterologous production in Streptomyces lividans.

Authors:  John J Barkei; Brian M Kevany; Elizabeth A Felnagle; Michael G Thomas
Journal:  Chembiochem       Date:  2009-01-26       Impact factor: 3.164

6.  Interpretation of tandem mass spectra obtained from cyclic nonribosomal peptides.

Authors:  Wei-Ting Liu; Julio Ng; Dario Meluzzi; Nuno Bandeira; Marcelino Gutierrez; Thomas L Simmons; Andrew W Schultz; Roger G Linington; Bradley S Moore; William H Gerwick; Pavel A Pevzner; Pieter C Dorrestein
Journal:  Anal Chem       Date:  2009-06-01       Impact factor: 6.986

7.  Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry of engine oil additive components.

Authors:  Lamprini Ramopoulou; Lukas Widder; Josef Brenner; Andjelka Ristic; Günter Allmaier
Journal:  Rapid Commun Mass Spectrom       Date:  2022-05-15       Impact factor: 2.586

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.