Vrutangkumar V Shah1, Carolin Curtze2, Kristen Sowalsky3, Ishu Arpan1, Martina Mancini1, Patricia Carlson-Kuhta1, Mahmoud El-Gohary3, Fay B Horak1,3, James McNames3,4.
Abstract
The "total distance walked" obtained during a standardized walking test is an integral component of physical fitness and health status tracking in a range of consumer and clinical applications. Wearable inertial sensors offer the advantages of providing accurate, objective, and reliable measures of gait while streamlining walk test administration. The aim of this study was to develop an inertial sensor-based algorithm to estimate the total distance walked using older subjects with impaired fasting glucose (Study I), and to test the generalizability of the proposed algorithm in patients with Multiple Sclerosis (Study II). All subjects wore two inertial sensors (Opals by Clario-APDM Wearable Technologies) on their feet. The walking distance algorithm was developed based on 108 older adults in Study I performing a 400 m walk test along a 20 m straight walkway. The validity of the algorithm was tested using a 6-minute walk test (6MWT) in two sub-studies of Study II with different lengths of a walkway, 15 m (Study II-A, n = 24) and 20 m (Study II-B, n = 22), respectively. The start and turn around points were marked with lines on the floor while smaller horizontal lines placed every 1 m served to calculate the manual distance walked (ground truth). The proposed algorithm calculates the forward distance traveled during each step as the change in the horizontal position from each foot-flat period to the subsequent foot-flat period. The total distance walked is then computed as the sum of walk distances for each stride, including turns. The proposed algorithm achieved an average absolute error rate of 1.92% with respect to a fixed 400 m distance for Study I. The same algorithm achieved an absolute error rate of 4.17% and 3.21% with respect to an averaged manual distance for 6MWT in Study II-A and Study II-B, respectively. These results demonstrate the potential of an inertial sensor-based algorithm to estimate a total distance walked with good accuracy with respect to the manual, clinical standard. Further work is needed to test the generalizability of the proposed algorithm with different administrators and populations, as well as larger diverse cohorts.Entities:
Keywords: 400 m walk test; 6MWD; 6MWT; inertial sensors; neurological disorders
Mesh:
Year: 2022 PMID: 35161822 PMCID: PMC8838103 DOI: 10.3390/s22031077
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Inertial sensor (Opal) placement on the foot dorsum.
Figure 2Example of walk trajectory used to calculate the total distance walked on a straight path (a) and with addition of a turn (b). The black dots show the position of the foot during the foot flat periods, the red trace shows the three-dimensional trajectory of the foot during each stride, and the black line segments show the horizontal distance traveled during each of the three strides. The total walk distance is then simply computed as the sum of walk distances for each stride.
Figure 3Histogram of error between 400 m and a total distance walked estimated by the proposed algorithm in 108 older adults (Study I). Vertical dashed line represents a mean of the histogram.
Figure 4Bland-Altman plot for agreement between a manually calculated walk distance and walk distance estimates using the proposed algorithm for 6MWT in (A) Study II-A (15 m walkway distance) and (B) Study II-B (20 m walkway distance). Bias (mean), upper (+1.96 SD) and lower (−1.96 SD) limit agreement are represented by blue, green, and red colors, respectively.