Literature DB >> 3516

Stability of fluorescent antibody conjugates stored under various conditions.

J H Green, S B Gray, W K Harrell.   

Abstract

Two experiments were carried out to determine the stability of fluorescent antibody conjugates. In experiment 1, Francisella tularemia conjugates in the lyophilized state retained their original staining titer for 1,294 days when stored at 25, 4 to 5, and -20 C; at 37 C the conjugates were stable for at least 65 days. In the liquid state at pH 7.4 and 8.0 these conjugates were stable for 1,294 days at 4 to 5 and -20 C, whereas those stored at 25 C remained stable through days 473 and 160 of storage, respectively, after which the staining titer gradually dropped. In experiment 2 five previously lyophilized conjugates were rehydrated with three different diluents and stored at 4 to 5 C for up to 600 days at their working dilutions. All of these conjugates retained their original staining titer during the test period except an anti-human globulin conjugate rehydrated with phosphate-buffered saline. Recommendations are made for the long-term storage of fluorescent antibody conjugates.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 3516      PMCID: PMC274216          DOI: 10.1128/jcm.3.1.1-4.1976

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  TECHNICAL CONSIDERATIONS IN THE PREPARATION OF FLUORESCENT-ANTIBODY CONJUGATES.

Authors:  V J LEWIS; W L JONES; J B BROOKS; W B CHERRY
Journal:  Appl Microbiol       Date:  1964-07

2.  Rapid identification of Pasteurella pestis with fluorescent antibody. II. Specific identification of Pasteurella pestis in dried smears.

Authors:  C C WINTER; M D MOODY
Journal:  J Infect Dis       Date:  1959 May-Jun       Impact factor: 5.226

3.  Shelf life of fluorescent treponemal antibody-absorption test reagents.

Authors:  M E Roberts; J N Miller; T C Pringle; G F Binnings
Journal:  J Bacteriol       Date:  1968-11       Impact factor: 3.490

4.  Preparation of agglutinating antisera and fluorescent-antibody conjugates against Pasteurella tularensis in equines.

Authors:  J H Green; R C Bolin; R K Carver; H Gross; N Pigott; W K Harrell
Journal:  Appl Microbiol       Date:  1970-06
  4 in total
  2 in total

1.  Long Shelf Life of a Lyophilized DNA Aptamer Beacon Assay.

Authors:  John G Bruno
Journal:  J Fluoresc       Date:  2016-12-30       Impact factor: 2.217

2.  Antigenic variation of Borrelia hermsii.

Authors:  H G Stoenner; T Dodd; C Larsen
Journal:  J Exp Med       Date:  1982-11-01       Impact factor: 14.307