Ye Eun Han1, Ho Seok Chung1,2, Hun Lee1, Jae Yong Kim1, Hungwon Tchah1.
Abstract
PURPOSE: To evaluate the clinical outcomes of nanothin Descemet stripping automated endothelial keratoplasty (DSAEK) in Korean patients with corneal endothelial dysfunction.Entities:
Keywords: Corneal endothelial dysfunction; Descemet stripping automated endothelial keratoplasty; Nanothin Descemet stripping automated endothelial keratoplasty
Mesh:
Year: 2022 PMID: 35067025 PMCID: PMC9013561 DOI: 10.3341/kjo.2021.0161
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Demographic and ocular characteristics of study subjects
| Variable | Value |
|---|---|
| Age[ | 61.18 ± 12.49 (40–87) |
| Male : female | 12 : 4 |
| Pseudophakia | 13 (81.25) |
| Diagnosis[ | |
| PBK | 7 (43.75) |
| BK of unknown origin | 2 (12.50) |
| PXS | 1 (6.25) |
| PPMD | 1 (6.25) |
| Herpes endothelitis | 1 (6.25) |
| ICE syndrome | 1 (6.25) |
| TASS | 1 (6.25) |
| Previous DSAEK graft failure | 2 (12.50) |
Values are presented as mean ± standard deviation (range), number, or number (%).
PBK = pseudophakic bullous keratopathy; BK = bullous keratopathy; PXS = pseudoexfoliation syndrome; PPMD = posterior polymorphous corneal dystrophy; ICE = iridocorneal endothelial; TASS = toxic anterior segment syndrome; DSAEK = Descemet stripping automated endothelial keratoplasty.
Age at the time of surgery;
Number of eyes.
Donor graft properties
| Variable | Value |
|---|---|
| Graft thickness after precut processing (μm) | 47.71 ± 7.91 (38–68) |
| Graft thickness after deswelling (μm) | 45.25 ± 4.59 (38–50) |
| Graft endothelial density (cells/mm2) | 2,859.62 ± 228.34 (2,545–3,390) |
Values are presented as mean ± standard deviation (range).
Preoperative and postoperative BCVA
| Preoperative BCVA | Postoperative BCVA | ||||
|---|---|---|---|---|---|
|
| |||||
| 1 mon | 3 mon | 6 mon | 12 mon | ||
| Mean (logMAR) | 1.37 ± 0.53 | 0.68 ± 0.46 | 0.55 ± 0.35 | 0.40 ± 0.25 | 0.39 ± 0.25 |
| Range (logMAR) | 0.10–2.00 | 0–1.80 | 0–1.30 | 0–0.82 | 0–0.82 |
| 0.005[ | <0.001[ | <0.001[ | <0.001[ | ||
Values are presented as mean ± standard deviation or range.
BCVA = best-corrected visual acuity; logMAR = logarithm of the minimum angle of resolution.
Significant difference compared to the preoperative value (p < 0.05, repeated measures ANOVA).
Fig. 1Changes in best-corrected visual acuity (BCVA) at four different follow-up visits after nanothin Descemet stripping automated endothelial keratoplasty. Error bars depicting ±standard deviation. *Significant difference compared to the preoperative value (p <0.05, repeated measure ANOVA). logMAR = logarithm of the minimum angle of resolution.
Preoperative and postoperative CCT
| Preoperative CCT | Postoperative CCT | ||||
|---|---|---|---|---|---|
|
| |||||
| 1 mon | 3 mon | 6 mon | 12 mon | ||
| Mean (μm) | 752.00 ± 129.11 | 592.57 ± 66.95 | 558.38 ± 64.12 | 549.67 ± 55.44 | 555.75 ± 54.66 |
| Range (μm) | 572–946 | 489–705 | 442–693 | 453–650 | 452–650 |
| 0.007[ | 0.004[ | 0.002[ | 0.006[ | ||
Values are presented as mean ± standard deviation or range.
CCT = central corneal thickness.
Significant difference compared to the preoperative value (p < 0.05, repeated measures ANOVA).
Fig. 2Changes in central corneal thickness (CCT) at four different follow-up visits after nanothin Descemet stripping automated endothelial keratoplasty. Error bars depicting ±standard deviation. *Significant difference compared to the preoperative value (p <0.05, repeated measure ANOVA).
Graft and postoperative ECD
| Graft ECD | Postoperative ECD | ||||
|---|---|---|---|---|---|
|
| |||||
| 1 mon | 3 mon | 6 mon | 12 mon | ||
| Mean (cells/mm2) | 2,859.62 ± 228.34 | 2,069.90 ± 613.75 | 1,872.00 ± 644.39 | 1,554.16 ± 577.23 | 1,542.25 ± 627.34 |
| Range (cells/mm2) | 2,545–3,390 | 1,149–3,125 | 1,145–2,915 | 513–2,183 | 538–2,309 |
| 0.294 | 0.106 | 0.015[ | 0.012[ | ||
Values are presented as mean ± standard deviation or range.
ECD = endothelial cell density.
Significant difference compared to the preoperative value (p < 0.05, repeated measure ANOVA).
Fig. 3Changes in graft endothelial cell density (ECD) at four different follow-up visits after nanothin Descemet stripping automated endothelial keratoplasty. Error bars depicting ±standard deviation. *Significant difference compared to the preoperative value (p <0.05, repeated measure ANOVA).
Fig. 4Anteiror slit photo, specular microscopy, and anterior segment optical coherence tomography of the eye (A) before and (B) 12 months after nanothin Descemet stripping automated endothelial keratoplasty (DSAEK). This is a 61-year-old male patient who underwent nanothin DSAEK for pseudophakic bullous keratopathy. Graft thickness was 43 μm with endothelial cell density of 2,950 cells/mm2. His preoperative visual acuity was 1.8 logarithm of the minimum angle of resolution, central corneal thickness was 845 μm, and endothelial cell density was uncheckable. One year after the surgery, visual acuity improved to 0.15 logarithm of the minimum angle of resolution and central corneal thickness to 605 μm, while graft endothelial cell density decreased to 1,129 cells/mm2. Informed consent for the publication of the clinical images was obtained from the patient.