Augmented reality and three-dimensional plate library-assisted posterior minimally invasive surgery for scapula fracture.

Qiang Guo1, Xiaoning Li1, Yifu Tang1, Yuzhao Huang1, Ling Luo2.   

Abstract

PURPOSE: Treating scapular fractures is still a challenging task for surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of augmented reality (AR) and three-dimensional (3D) plate library-assisted posterior minimally invasive surgery, named AR-scapular system for scapula fracture. We speculated that using AR-scapular system would improve efficiency and quality for scapular fracture surgery.
METHODS: We retrospectively reviewed the records of 21 patients with scapular fractures treated by posterior minimally invasive surgery with reconstruction plates: nine patients were treated with conventional fixation in group I; whereas 12 patients were treated with pre-operative virtual simulation and intra-operative navigation-assisted fixation using AR-scapular system. We compared operative time, blood loss, complication, and Hardegger function between two groups. Statistical analyses evaluated significant differences between the groups for each of these variables.
RESULTS: In group II, the pre-operative virtual simulation time was 44.42 ± 15.54 min. The time required for pre-operative contouring of the plates was 16.08 ± 5.09 minutes. The patients in group II had significantly shorter operation time and less blood loss (- 28.75 min and - 81.94 ml, respectively; P < 0.05) than patients in the conventional surgery group. The average numbers of plates used were 1.56 ± 0.53 in group I and 1.25 ± 0.45 in group II. The difference was not statistically significant (P > 0.05). The follow-up function outcome results were similar between groups (P > 0.05). There were no intra-operative or post-operative complications for all patients.
CONCLUSION: Augmented reality and 3D plate library-assisted posterior minimally invasive surgery is an effective and reliable method for treating scapular fractures which can provide precise pre-operative planning and intraoperative navigation. This time-saving approach can give a more customized treatment plan, allowing for a safer reduction surgery. What is more, the portable projector is cheap and easy to use.
© 2022. The Author(s) under exclusive licence to SICOT aisbl.

Entities:  

Keywords:  3D plate library; Augmented reality; Portable projector; Pre-operative planning; Scapula fracture

Mesh:

Year:  2022        PMID: 35061064     DOI: 10.1007/s00264-022-05303-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  15 in total

1.  [SURGICAL TREATMENT OF SCAPULAR FRACTURES].

Authors:  R JUDET
Journal:  Acta Orthop Belg       Date:  1964       Impact factor: 0.500

2.  Analysis of operative versus nonoperative treatment of displaced scapular fractures.

Authors:  Clifford B Jones; Debra L Sietsema
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

3.  Scapular body fractures: results of operative treatment.

Authors:  Jan Bartoníček; Vladimír Frič
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

4.  A Comparison of Exposure Between the Classic and Modified Judet Approaches to the Scapula.

Authors:  Luke S Harmer; Kevin D Phelps; Colin V Crickard; Katherine M Sample; Erica B Andrews; Nady Hamid; Joseph R Hsu
Journal:  J Orthop Trauma       Date:  2016-05       Impact factor: 2.512

5.  Surgical technique: a minimally invasive approach to scapula neck and body fractures.

Authors:  Erich M Gauger; Peter A Cole
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

6.  Conservative treatment of scapular neck fracture: the effect of stability and glenopolar angle on clinical outcome.

Authors:  Murat Bozkurt; Filiz Can; Vecihi Kirdemir; Zafer Erden; Ismail Demirkale; Mustafa Başbozkurt
Journal:  Injury       Date:  2005-07-27       Impact factor: 2.586

7.  Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

Authors:  Chun-Chi Hung; Yuan-Ta Li; Yu-Ching Chou; Jia-En Chen; Chia-Chun Wu; Hsain-Chung Shen; Tsu-Te Yeh
Journal:  Int Orthop       Date:  2018-05-03       Impact factor: 3.075

Review 8.  Operative treatment of scapular fractures: a systematic review.

Authors:  Jacob M Lantry; Craig S Roberts; Peter V Giannoudis
Journal:  Injury       Date:  2007-10-04       Impact factor: 2.586

9.  Fractures of the scapula: long-term results after conservative treatment.

Authors:  Markus D Schofer; Axel C Sehrt; Nina Timmesfeld; Sabine Störmer; Horst R Kortmann
Journal:  Arch Orthop Trauma Surg       Date:  2009-03-21       Impact factor: 3.067

Review 10.  Current challenges and controversies in the management of scapular fractures: a review.

Authors:  Robinson Esteves Pires; Vincenzo Giordano; Felipe Serrão Mendes de Souza; Pedro José Labronici
Journal:  Patient Saf Surg       Date:  2021-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.