OBJECTIVES: To compare cemented and screw-retained one-piece zirconia-based restorations in terms of clinical, radiographic, and technical outcomes 5 years after insertion.Entities:
Keywords: cemented; crowns; dental abutments; screw-retained; single-tooth dental implants
Mesh:
Substances:
Year: 2022 PMID: 35051314 PMCID: PMC9305781 DOI: 10.1111/clr.13895
Source DB: PubMed Journal: Clin Oral Implants Res ISSN: 0905-7161 Impact factor: 5.021
FIGURE 1Group CEM, cemented all‐ceramic crown 11; (a) at Baseline examination; (b) at the 5‐year follow‐up
FIGURE 2Group SCREW screw‐retained all‐ceramic crown 12; (a) at Baseline examination; (b) at the 5‐year follow‐up
Marginal bone levels at baseline and at 5‐year follow‐up
| Cemented | Screw‐retained |
| ||
|---|---|---|---|---|
| Baseline |
| 17 | 16 | |
| Mean ± SD | −0.06 mm ± 0.63 | 0.16 mm ± 0.53 | 0.5271 | |
| Median (Q1;Q3) | 0.05 mm (−0,66; 0.33) | 0.03mm (−0.21; 0.49) | ||
| 5 year follow‐up |
| 13 | 13 | |
| Mean ± SD | −0.39 mm ± 0.82 | −0.2 mm ± 0.28 | 0.9598 | |
| Median (Q1;Q3) | −0.15 mm (−0.89; 0.27) | −0.26 mm (−0.38; −0.01) | ||
| change |
| 13 | 13 | 0.1690 |
| Mean ± SD | −0.34 mm ± 0.31 | −0.20 mm ± 0.41 | ||
| Median (Q1;Q3) | −0.23 mm (−0.55; −0.07) | −0.15 mm (−0.51; −0.11) |
Abbreviations: SD, Standard deviation; Q1, quartile 1; Q3, quartile 3.
Clinical parameters at baseline and at the 5‐year follow‐up
| Variable | Cemented | Screw‐retained | ||||
|---|---|---|---|---|---|---|
| Mean ± SD | Median (Q1; Q3) | Mean | Median (Q1; Q3) | |||
| Baseline | BOP (%) | Implant | 32.4 ± 26.7 | 33.3 (0.0; 58.3) | 16.7 ± 14.9 | 16.7 (0.0; 33.3) |
| Tooth | 15.1 ± 15.3 | 16.7 (0.0; 25) | 24.0 ± 15.5 | 25 (8.3; 33.3) | ||
| PCR (%) | Implant | 9.8 ± 20.5 | 0 (0.0; 8.3) | 5.2 ± 10.0 | 0 (0.0; 12.5) | |
| Tooth | 19.8 ± 21.7 | 12.5 (0.0; 39.6) | 18.8 ± 18.4 | 16.7 (0.0; 31.3) | ||
| PD (mm) | Implant | 2.9 ± 0.51 | 2.8 (2.5; 3.3) | 3.0 ± 0.58 | 2.9 (2.7; 3.2) | |
| Tooth | 2.2 ± 0.46 | 2.3 (1.8; 2.5) | 2.3 ± 0.4 | 2.4 (2.0; 2.7) | ||
| KT (mm) | Implant | 3.0 ± 1.4 | 3.0 (2.0; 4.0) | 3.9 ± 0.9 | 4.0 (3.0; 5.0) | |
| Tooth | 3.1 ± 1.4 | 2.5 (2.4; 4) | 3.8 ± 1.2 | 4.0 (2.8; 4.5) | ||
| 5 year follow‐up | BOP (%) | Implant | 37.2 ± 32.0 | 33.3 (16.7; 66.6) | 33.3 ± 28.4 | 33.3 (4.2; 50) |
| Tooth | 21.2 ± 26.5 | 8.3 (0.0; 45.8) | 28.5 ± 26.0 | 25 (8.3; 47.9) | ||
| PCR (%) | Implant | 12.8 ± 15.4 | 0.0 (0.0; 33.3) | 6.9 ± 11.1 | 0.0 (0.0; 16.7) | |
| Tooth | 30.1 ± 28.4 | 25 (4.2; 50.0) | 29.2 ± 25.3 | 29.2 (4.2; 33.3) | ||
| PD (mm) | Implant | 3.2 ± 0.6 | 3.3 (2.8; 3.6) | 3.2 ± 0.5 | 3.1 (2.7; 3.5) | |
| Tooth | 2.3 ± 0.3 | 2.3 (2.0; 2.6) | 2.6 ± 0.5 | 2.6 (2.3; 2.8) | ||
| KT (mm) | Implant | 3.0 ± 1.4 | 3.0 (2.0; 3.5) | 3.5 ± 0.7 | 4.0 (3.0; 4.0) | |
| Tooth | 3.0 ± 1.3 | 3.0 (2.3; 3.8) | 3.5 ± 1.2 | 3.8 (2.3; 4.5) | ||
Abbreviations: BOP, Bleeding on probing; PCR, plaque control record; PD, probing depth; KT, keratinized tissue; implant, implant site; tooth, contralateral tooth.
Technical outcome measures (USPHS) at baseline and at the 5‐year follow‐up
| Cemented | Screw‐retained | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| A | B | C | D | A | B | C | D | ||
| Baseline | Patient's satisfaction | 17 | 0 | 0 | 0 | 16 | 0 | 0 | 0 |
| Marginal adaptation | 16 | 1 | 0 | 0 | |||||
| Veneering fracture | 15 | 2 | 0 | 0 | 16 | 0 | 0 | 0 | |
| Abutment fracture | 17 | 0 | 16 | 0 | |||||
| Anatomical form | 17 | 0 | 0 | 16 | 0 | 0 | |||
| Proximal contact mesial | 12 | 4 | 1 | 11 | 3 | 2 | |||
| Proximal contact distal | 10 | 5 | 1 | 11 | 2 | 3 | |||
| Occlusion | 13 | 0 | 4 | 14 | 0 | 2 | |||
| Occlusal wear | 17 | 0 | 0 | 16 | 0 | 0 | |||
| Color | 17 | 0 | 0 | 16 | 0 | 0 | |||
| X‐ray: cementation gap visible | 16 | 1 | 0 | 0 | |||||
| After 5 year follow‐up | Patient's satisfaction | 13 | 0 | 0 | 0 | 13 | 0 | 0 | 0 |
| Marginal adaptation | 10 | 3 | 0 | 0 | |||||
| Veneering fracture | 11 | 2 | 0 | 0 | 12 | 1 | 0 | 0 | |
| Abutment fracture | 13 | 0 | 12 | 1 | |||||
| Anatomical form | 13 | 0 | 0 | 12 | 1 | 0 | |||
| Proximal contact mesial | 6 | 3 | 4 | 3 | 3 | 7 | |||
| Proximal contact distal | 8 | 4 | 0 | 7 | 3 | 3 | |||
| Occlusion | 11 | 0 | 2 | 8 | 0 | 5 | |||
| Occlusal wear | 8 | 5 | 0 | 11 | 2 | 0 | |||
| Color | 12 | 1 | 0 | 13 | 0 | 0 | |||
| X‐ray: cementation gap visible | 13 | 0 | 0 | 0 | |||||
Abbreviations: A, Alpha; B, Bravo; C, Charlie; D, Delta.
Esthetic parameters at baseline and at the 5‐year follow‐up
| Variable | Cemented | Screw‐retained | |||
|---|---|---|---|---|---|
| Mean ± SD | Median (Q1; Q3) | Mean ± SD | Median (Q1; Q3) | ||
| Baseline | Papilla index mesial | 1.7 ± 0.8 | 2 (1; 2) | 1.7 ± 0.7 | 2 (1; 2) |
| Papilla index distal | 1.4 ± 0.7 | 1 (1; 2) | 1.4 ± 0.6 | 1 (1; 2) | |
| Crown height (mm) | 9.2 ± 1.2 | 9.0 (9.0; 10.0) | 9.1 ± 2.0 | 9.3 (7.3; 10.4) | |
| Mucosa thickness (mm) | 3.4 ± 1.0 | 4.0 (2.5; 4.0) | 4.1 ± 1.1 | 4.0 (3.3; 5.0) | |
| 5‐year follow‐up | Papilla index mesial | 2.1 ± 0.9 | 2 (1; 3) | 1.8 ± 0.8 | 2 (1; 2.8) |
| Papilla index distal | 1.8 ± 0.7 | 2 (1; 2) | 1.7 ± 0.7 | 2 (1; 2) | |
| Crown height (mm) | 9.8 ± 1.4 | 9.5 (9; 10.8) | 9.1 ± 2.1 | 9.0 (7.1; 10.0) | |
| Mucosa thickness (mm) | 2.5 ± 0.9 | 2.5 (2.0; 3.0) | 2.8 ± 0.9 | 2.8 (2; 3.4) | |
Abbreviations: SD, Standard deviation; Q1, quartile 1; Q3, quartile 3.