OBJECTIVE: The aim of this clinical study was to assess complications, success, and survival rates of zirconia abutments from different implant designs.
MATERIAL AND METHODS: Anterior implant-supported single-tooth restorations, after 1-12 years of clinical function, were evaluated. One hundred and fifty-eight zirconia implant abutments placed in 141 patients were evaluated. Mechanical complications were observed, such as presence or absence of abutment fractures and loss of retention. In addition, the peri-implant parameters were observed. Statistical analysis was performed using Fisher's exact tests, and bone level was analyzed using the nonparametric Mann-Whitney U-test for non-normally distributed data.
RESULTS: Sixteen restorations exhibited different complications. However, no significant difference was observed between the standard and platform switching. The standard platforms exhibited higher marginal bone loss than platform switching design followed up to 5 years. Platform switching has a potentially higher risk of fracture in some designs. In our study, one standard platform as well as two-platform switch designs seem to withstand fracture in the anterior area, regardless of the implant width. Survival and success rates were 93.8% and 81.2% (up to >7 years ≤12), respectively, for standard platform; and 90 and 84% (up to >2 years ≤5), respectively, for platform switching.
CONCLUSIONS: In general, standard platform implants restored with zirconia abutments were successful for the longest periods of observation and are a viable treatment alternative in anterior areas. Some of the studied designs of platform switching implants with zirconia abutments performed well for up to 5 years.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  ceramic abutments; implant abutments; survival; zirconia

Mesh:

Substances:

Year:  2014        PMID: 25346234     DOI: 10.1111/clr.12504

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

Review 1.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

2.  Titanium Base Abutments in Implant Prosthodontics: A Literature Review.

Authors:  Ahmad M Al-Thobity
Journal:  Eur J Dent       Date:  2021-11-18

3.  Cemented versus screw-retained zirconia-based single-implant restorations: 5-year results of a randomized controlled clinical trial.

Authors:  Sofia T Lamperti; Karin Wolleb; Christoph H F Hämmerle; Ronald E Jung; Jürg Hüsler; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-02-02       Impact factor: 5.021

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.