BACKGROUND: In recent years, pediatric endodontics has witnessed various advances including use of rotary files in pulpectomy. This study aimed to comparatively evaluate taper, amount of dentin removal and instrumentation time of the pediatric rotary Kedo-S Square file, hand K-files and H-files in primary canines using cone beam computed tomography (CBCT).Entities:
Keywords: Cone-beam computed tomography; Hand H-files; Hand K-files; Kedo-S-Square rotary file; Primary teeth; Pulpectomy
Mesh:
Year: 2022 PMID: 35042489 PMCID: PMC8764846 DOI: 10.1186/s12903-021-02021-0
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Tapering ability of Kedo-S Square file, K- and H-files
Fig. 2Pictorial representation showing sagittal cut of CBCT: a Pre- and Post-preparation CBCT scan images showing good taper with Kedo-S Square rotary file. b Pre- and Post-preparation CBCT scan images showing poor taper with manual K and H files
Fig. 3Mean residual dentin thickness (mm) following use of Kedo-S Square file, K- and H-files before and after instrumentation at different levels
Comparison of percent reduction in Dentin thickness among three files at different levels
| Percent reduction | Kedo-S square file | K-file | H-file | H test | |
|---|---|---|---|---|---|
| 3 mm | Mean ± SD | 12.79 (6.60) | 19.09 (6.70) | 20.92 (6.85) | 12.843 |
| Median (IQR) | 14.02 (12.80)a | 19.77 (9.42)b | 21.51 (8.88)b | ||
| 6 mm | Mean ± SD | 13.41 (7.11) | 17.76 (8.79) | 16.60 (4.09) | 5.120 (0.077) |
| Median (IQR) | 12.75 (8.65) | 15.71 (4.90) | 16.34 (4.49) | ||
| 9 mm | Mean ± SD | 11.96 (7.27) | 14.46 (5.62) | 16.31 (4.19) | 8.554 |
| Median (IQR) | 10.84 (9.78)a | 13.85 (7.56)ab | 16.90 (6.41)b | ||
H test: Kruskal–Wallis test
*Statistically significant different at p value ≤ 0.05
a,bDifferent letters denote significant difference between groups