Literature DB >> 17183182

In vitro comparison of NiTi rotary instruments and stainless steel hand instruments in root canal preparations of primary and permanent molar.

P J Nagaratna1, N D Shashikiran, V V Subbareddy.   

Abstract

This study is an attempt to compare the NiTi rotary and K-files hand instrumentation on root canal preparation of primary and permanent molars for their efficiency in preparation time, instrument failure and shaping the canals. About 20 primary mandibular second molar (I) and 20 permanent mandibular first molar (II) were selected. Each was further divided into 10 for K-files (a) and 10 for NiTi (b) groups, respectively. Results showed that preparation time Ib Ia and IIab<IIa, which was highly significant. In instrument failure, Ia (40%), IIa (30%) showed more deformation but not fracture and Ib (10%), IIb (20%) showed fracture, but not deformation. Profiles showed good canal taper and smoothness compared to the K-files. To conclude profile 0.04 taper 29 series, prepared canal rapidly than conventional K-file with good taper, smoothness though the flow was not satisfactory. Instrument failure with K-files was less. In primary teeth preparation time, instrument failure with profile was less compared to the permanent. To conclude it's encouraging to use the profiles in primary teeth.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17183182     DOI: 10.4103/0970-4388.28075

Source DB:  PubMed          Journal:  J Indian Soc Pedod Prev Dent        ISSN: 0970-4388


  25 in total

1.  Kedo-S Paediatric Rotary Files for Root Canal Preparation in Primary Teeth - Case Report.

Authors:  Ganesh Jeevanandan
Journal:  J Clin Diagn Res       Date:  2017-03-01

2.  Clinical comparison of Kedo-S paediatric rotary files vs manual instrumentation for root canal preparation in primary molars: a double blinded randomised clinical trial.

Authors:  G Jeevanandan; L Govindaraju
Journal:  Eur Arch Paediatr Dent       Date:  2018-07-12

3.  Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.

Authors:  Haridoss Selvakumar; Swaminathan Kavitha; Eapen Thomas; Vasanthakumari Anadhan; Rajendran Vijayakumar
Journal:  J Clin Diagn Res       Date:  2016-01-01

4.  Comparing the amount of removed dentin thickness in root canal treated primary molar teeth using different instrumentation techniques: in-vitro study using CBCT.

Authors:  Y Ghahramani; N Mohammadi; M Zangooei-Booshehri; S Shirdel
Journal:  Eur Arch Paediatr Dent       Date:  2021-09-07

5.  Evaluation of the efficacy of rotary vs. hand files in root canal preparation of primary teeth in vitro using CBCT.

Authors:  P K Musale; S A V Mujawar
Journal:  Eur Arch Paediatr Dent       Date:  2013-07-27

6.  Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth.

Authors:  Mohammad Reza Azar; Laya Safi; Afshin Nikaein
Journal:  Dent Res J (Isfahan)       Date:  2012-03

7.  An in vitro comparison of root canal system prepared with either hand or rotary instruments.

Authors:  Azza A Dafalla; Neamat Hassan Abubakr; Yahia E Ibrahim
Journal:  Iran Endod J       Date:  2010-11-15

8.  Impact of root canal preparation size and taper on coronal-apical micro-leakage using glucose penetration method.

Authors:  Mehdi Tabrizizadeh; Maryam Kazemipoor; Seyed-Hossein Hekmati-Moghadam; Roqayeh Hakimian
Journal:  J Clin Exp Dent       Date:  2014-10-01

Review 9.  Rotary endodontics in primary teeth - A review.

Authors:  Sageena George; S Anandaraj; Jyoti S Issac; Sheen A John; Anoop Harris
Journal:  Saudi Dent J       Date:  2015-11-22

10.  Radiographic assessment and chair time of rotary instruments in the pulpectomy of primary second molar teeth: a randomized controlled clinical trial.

Authors:  Abbas Makarem; Navid Ravandeh; Masoumeh Ebrahimi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-06-11