Spatially resolving the relative distribution of analyte molecules in biological matter holds great promise in the life sciences. Mass spectrometry imaging (MSI) is a technique that can provide such spatial resolution but remains underused in fields such as chemical ecology, as traditional MSI sample preparation is often chemically or morphologically invasive. Laser ablation electrospray ionization (LAESI)-MSI is a variation of MSI particularly well-suited for situations where chemical sample preparation is too invasive but provides new challenges related to the repeatability of measurement outcomes. We assess the repeatability of LAESI-MSI by sampling a droplet of [ring-13C6]l-phenylalanine with known concentration and expressing the resulting variability as a coefficient of variation, cv. In doing so, we entirely eliminate variability caused by surface morphology or underlying true sample gradients. We determine the limit of detection (LOD) for13C6-Phe by sampling from droplets with successively decreasing but known concentration. We assess the influence of source geometry on the LOD and repeatability by performing these experiments using four distinct variations of sources: one commercial and three custom-built ones. Finally, we extend our study to leaf and stem samples Arabidopsis thaliana and Gossypium hirsutum. We overcome the challenges of LAESI associated with three-dimensional surface morphology by relying on work previously published. Our measurements on both controlled standard and realistic samples give strong evidence that LAESI-MSI's repeatability in current implementations is insufficient for MSI in chemical ecology.
Spatially resolving the relative distribution of analyte molecules in biological matter holds great promise in the life sciences. Mass spectrometry imaging (MSI) is a technique that can provide such spatial resolution but remains underused in fields such as chemical ecology, as traditional MSI sample preparation is often chemically or morphologically invasive. Laser ablation electrospray ionization (LAESI)-MSI is a variation of MSI particularly well-suited for situations where chemical sample preparation is too invasive but provides new challenges related to the repeatability of measurement outcomes. We assess the repeatability of LAESI-MSI by sampling a droplet of [ring-13C6]l-phenylalanine with known concentration and expressing the resulting variability as a coefficient of variation, cv. In doing so, we entirely eliminate variability caused by surface morphology or underlying true sample gradients. We determine the limit of detection (LOD) for13C6-Phe by sampling from droplets with successively decreasing but known concentration. We assess the influence of source geometry on the LOD and repeatability by performing these experiments using four distinct variations of sources: one commercial and three custom-built ones. Finally, we extend our study to leaf and stem samples Arabidopsis thaliana and Gossypium hirsutum. We overcome the challenges of LAESI associated with three-dimensional surface morphology by relying on work previously published. Our measurements on both controlled standard and realistic samples give strong evidence that LAESI-MSI's repeatability in current implementations is insufficient for MSI in chemical ecology.
Mass
spectrometry imaging (MSI) is a rapidly growing field with
an equally fast growing number of applications in lipidomics,[1,2] proteomics,[3,4] biotyping,[5−7] and medical
research.[8−10] The workhorse ion sources at the forefront of this
development, matrix-assisted laser desorption/ionization (MALDI)[11] and desorption electrospray ionization (DESI),[12] have a proven record of reliability. They do,
however, impose strict requirements on sample preparation and the
sample’s surface morphology.For example, the sample
surface is ideally as flat as possible
to guarantee uniform analysis. Not every surface of analytical interest
is flat, however, especially so in nonmedical life sciences. How to
achieve uniform surface analysis in spite of nonflat surfaces has
been the topic of much discussion in recent years.[13−16]MALDI additionally requires
the sample to be coated in a matrix
compound prior to analysis, which may alter the chemical state of
the sample prior to the actual analysis. MALDI and DESI are therefore
avoided in scientific fields where any form of extensive sample preparation
could be detrimental to the success of an experiment. One of these
fields is chemical ecology, where the molecular composition of a sample
at a defined point in time is of crucial interest. In this context,
altered chemical states may lead to the wrong conclusions.Laser
ablation electrospray ionization (LAESI) is a potential alternative
to MALDI. In LAESI, ionization is facilitated by an electrospray (ESI),
reducing the need for sample preparation greatly.[17] Although LAESI has been applied successfully to various
samples over the past decade,[18−21] its use in MSI continues to be infrequent.In our experiments on Arabidopsis thaliana and Gossypium hirsutum, the measured
intensity values exhibited an unexpected pixel-to-pixel variability.
This observation had several conceivable explanations, which we combined
in three experimentally assessable groups: first, the unexpected variability
resulted directly from biology, that is, unexpected differences in
local metabolite concentrations, water content, and/or tensile strength
of the tissue in question; second, the electrospray providing the
ionization capabilities of the LAESI ion source was not stable during
the MSI experiments; or third, the ion yield of the ionization step
was at least partially subject to randomness. We hypothesize that,
in LAESI, ion yield is responsible for the variability because the
ablation, and ESI plumes do not always interact equally.In
the following, we present the results of our investigation into
the matter and discuss why the experimental evidence suggests explanation
three to be the answer. To support our argument, we determined the
repeatability of three custom-built and a commercial LAESI ion source
by repeatedly sampling the same concentration of 13C6-Phe. Here, we also include the effects of normalization.
Methods
Custom-Built
LAESI Ion Sources
For this work, three
distinct variations on the LAESI ion source concept were custom-built,
based on a prototype LAESI ion source with topographically guided
laser ablation, as described earlier.[15] All three ion sources used the same ESI capillary (part no. 700000341,
Waters, Milford, MA, USA) and solvent delivery system, a LC-20AD Prominence
binary pump (Shimadzu, Kyoto, Japan) together with a 1100 series degassing
unit (Agilent, Santa Clara, CA, USA), the same four-dimensional sample
manipulation system comprising two MZS50/M-Z8, a MZS25/M-Z8, and a
DDS220/M linear translation stage (Thorlabs, Newton, NJ, USA). The
optical pathway for all three ion sources consisted of four turning
mirrors (PF10-03-M01, Thorlabs) in kinematic mounts (KCB1/M and KCB1C/M,
Thorlabs), a wire-grid polarizer (WP25M-UB, Thorlabs) in a rotating
mount (CRM1/M, Thorlabs) for laser energy attenuation, a 2 mm pinhole
(custom-built, Thorlabs), and a 1:10 telescope (LA5315-E and LA5714-E,
Thorlabs) to widen the beam in front of the focusing lens. The focusing
lens was an aspheric ZnSe lens with either 50 mm (AL72550-E, Thorlabs)
or 25 mm (AL72525-E, Thorlabs), depending on the source geometry.
In the case of the 25 mm focusing lens, an additional turning mirror
(MRA25-M01) was necessary. The smallest achievable ablation mark diameters
on thermoactive paper and the living tissue of Gossypium
hirsutum was 30 μm on average. In MSI experiments,
the ablation mark diameter was maximized to fit the lateral resolution.
We avoided oversampling through profilometry and controlled defocusing,
as described in a previous publication.[15] In all setups, a stable electrospray was achieved with 1% (v/v)
formic acid and 100 ng mL–1 leucine enkephalin in
a 1:1:1:1 (v/v/v/v) mixture of water, methanol, isopropyl alchol,
and acetonitrile, at a flow rate of 1.2 μL min–1 and a capillary voltage of 3.5 to 4.1 kV and from −3.6 to
−4.2 kV for positive and negative ion mode, respectively. The
same Synapt HDMS TOF-MS (Waters) was used with all three LAESI ion
source variations.Each variation on the LAESI ion source concept,
schematic representations of which are shown in Figure , was designed to investigate a particular
aspect of the ionization step in the LAESI process. The first variation,
henceforth referred to as the classic LAESI geometry, was designed
to resemble as closely as possible the geometry described in the original
LAESI publication,[17] while retaining the
optics and sample manipulation system described above. To achieve
this resemblance, the ESI emitter was placed directly in front of
the MS inlet at a distance of 10 mm and 14 mm above the focal point
of the AL72550-E focusing lens. The laser axis intersected the axis
between MS inlet and ESI capillary 6.0 mm in front of the ESI emitter.
Figure 1
Schematic
representations of the investigated LAESI ion source
geometries, namely, coaxial ionization (I), the ionization chamber
(II), and classic LAESI geometries (III), as well as the commercial
DP-1000 LAESI ion source (IV).
Schematic
representations of the investigated LAESI ion source
geometries, namely, coaxial ionization (I), the ionization chamber
(II), and classic LAESI geometries (III), as well as the commercial
DP-1000 LAESI ion source (IV).In the second variation, in the following referred to as ionization
chamber geometry, the interaction of the ablation and ESI plume took
place in a chamber rather than in front of the MS inlet. The transport
of ions to the mass spectrometer was facilitated by a steel capillary.
Inside the ionization chamber, the ESI emitter was placed 10 mm in
front of the steel capillary tube and 13 mm above the focal point
of the AL72525-E lens. The laser axis intersected the axis between
the steel and ESI capillary tubes 6.5 mm in front of the ESI emitter.In the third variation, henceforth referred to as the coaxial ionization
geometry, the laser ablation step and the electrospray ionization
were spatially separated. The ESI emitter was positioned 10 mm in
front of the MS inlet within an airtight housing. Stainless-steel
capillary tubes (U-139 and U-145, IDEX Corporation, Lake Forest, IL,
USA) and a P-714 PEEK tee-connector (IDEX) were used to construct
an ablation plume transfer capillary tube and a sheath-gas capillary
tube; these were connected to allow ablated sample material to be
incorporated into the gas stream around the ESI (the gas stream made
a sheath of the atmosphere sucked in by the vacuum of the MS instrument).
The opening of the capillary tube in which the ablation plume transfer
took place was positioned 13 mm above the focal point of the AL72525-E
lens and 3.0 mm off the optical axis.All experiments were conducted
with a commercially available LAESI
DP-1000 ion source (Protea Bioscience, Morgantown, WV, USA) as a control
against any construction bias of our custom-built ion sources. In
all experiments, the DP-1000 was connected to the same XEVO qTOF instrument
(Waters). In the DP-1000 LAESI ion source, the laser axis intersected
the axis between MS inlet capillary and ESI capillary, which were
11 mm apart, 6.0 mm in front of the ESI emitter and roughly 14 mm
above the focal point of the laser.
LAESI-MSI with Topographically
Guided Laser Ablation
All MSI experiments presented here
were conducted with the classic
LAESI ion source geometry that made use of our previously published
approach[15] to use profilometric data to
move the sample up and down to compensate for a nonflat surface morphology.
Spatial context was provided by recording laser activity as a squared
voltage signal in the analog channel of the Synapt Instrument. An
Arduino UNO microcontroller, expanded upon with a Screw Shield 1.0
(Conrad Electronic SE, Hirschau, Germany), was positioned between
the Q-switch output of the laser and the analog input channel of the
MS instrument to elongate and transform the squared signal emitted
by the laser. Assignment of mass spectra and conversion of the raw
data to imzML data sets[22] was done in the
R software environment (v3.6.0., R Development Core Team, 2019), with
the help of the MALDIquant package.[23,24]For
experiments on A. thaliana, the fifth
leaf of a plant was separated from the rosette and fixed with the
abaxial side up to a microscope slide with double-sided adhesive tape.
The height profile of a region of interest (ROI), usually 10 by 5
mm, was measured by the integrated profilometer at a lateral resolution
of 200 μm. Based on the height profile acquired, the ROI was
then sampled at the same lateral resolution, with the compensatory
sample stage movement along the vertical axis to account for the nonflat
surface morphology of the leaf. Laser ablation took place with 20
laser pulses per position, at a repetition rate of 20 Hz and an laser
energy of 35(1) μJ per pulse, to account for the nonflat surface
morphology of the leaf.The experiments on G.
hirsutum were
performed on transversally cut stems that were positioned flat side
down on microscope glass slides without further fixation. ROIs measured
2 by 1 mm and were sampled at a lateral resolution of 100 μm
with 20 laser pulses at 20 Hz repetition rate and an energy of 71(2)
μJ per pulse after the corresponding height profile was measured
for topographical guidance. Optical images were taken pre- and postexperiment
with a VHX-5000 digital stereomicroscope in conjunction with a VH-Z20R
objective and an OP-87429 polarization filter (Keyence, Osaka, Japan).
Determination of the 13C6-Phe Limit of
Detection (LOD)
Standard solutions of 1, 10, 50, 100, and
500 μg mL–1 [ring-13C6]l-phenylalanine concentration were prepared from a stock
solution (Cambridge Isotope Laboratories Inc., Tewksbury, MA, USA).
From each of these solutions, three droplets of 2 μL volume
were sampled, one at a time, with 11 bursts of five laser pulses at
20 Hz repetition rate and a laser energy of approximately 75 μJ
per pulse. A droplet of 20 μL volume had to be provided in the
case of the DP-1000 ion source because the increased beam diameter
led to an increased amount of sample being ablated. Laser ablation
in the DP-1000 ion source took place at 10 Hz and 1 mJ laser energy
per pulse. For the purposes of evaluation, the intensity value of
the m/z 126.11 fragment was considered
instead of the response of the protonated molecule. A signal-to-noise
(S/N) threshold of 4 was used to determine the LOD.Statistical
analysis was performed in the R software environment. The signal variation,
which increased with increasing concentrations, made it necessary
to describe the influence of the concentration on the signal intensity
with a quadratic regression model. The variance heterogeneity was
accounted for using a generalized least-squares method (function “gls”
of the “nlme” library[25])
employing the “varPower” or the “varExp”
structure to weight the residual variances. The variance structure
was determined by the model and a likelihood ratio test, as well as
by selecting the model with the smallest AIC.[26]
Determination of the Coefficient of Variation
The coefficient
of variation, cv, of all four LAESI ion
sources was determined experimentally by sampling a droplet of the 13C6-Phe standard of known concentration multiple
times in short succession. To this end, a 2 μL droplet of 13C6-Phe standard was sampled with 11 bursts of
five laser pulses at 20 Hz repetition rate, a laser energy of approximately
75 μJ per pulse, with a 2 s break between each sampling. In
the LAESI DP-1000 ion source, a 20 μL droplet was sampled at
a 10 Hz repetition rate and a laser energy of approximately 1 mJ per
pulse. The concentration of 13C6-Phe in the
droplet presented was 100 μg mL–1 in the ionization
chamber and classic LAESI geometry as well as in the DP-1000 ion source.
For the sample involving coaxial ionization geometry, the concentration
was increased to 500 μg mL–1 to ensure a sufficient
response. The experiment was repeated ten times in each ionization
source. The intensity value of the m/z 126.11 fragment was measured for each source. The coefficient of
variation, cv, was consistently calculated
as the ratio between standard deviation (σ) and mean intensity
(x̅) of m/z 126.11. The experiments to determine the cv were also performed without presenting droplets to assess
the influence of ablation plume expansion on electrospray stability.
ESI Current Measurements
The electric current drawn
by the electrospray was measured during the experiments determining
the cv. The custom-built ESI current meter
(IOCB, Prague, Czechia) was situated between the power supply of the
MS instrument and the ESI emitter and translated the drawn current
into a recordable voltage signal. A NI-6008 DAQ device (National Instruments,
Austin, TX, USA) was used to record this voltage signal; a second
voltage signal indicated the laser activity of the laser’s
power supply unit.
Results and Discussion
We performed LAESI-MSI on the surface
of G. hirsutum stems for the first
time. The application of topographical guidance
was essential in compensating for the surface curvature of the stems
and therefore to ensure the consistent laser ablation necessary for
LAESI-MSI. Figure shows results of LAESI-MSI on a representative stem sample, obtained
with our custom LAESI ion source configured in the classic LAESI geometry.
As observable in panel II, laser ablation was consistent except for
the left most rows, marked in red. At the marked sampling positions,
laser ablation failed because the curvature of the stem’s surface
was too high for reliable profilometry. A three-dimensional rendering
of the ROI (panel III), based on an acquired Z-stack
of optical images taken postablation, illustrates the correlation
between failed laser ablation and surface curvature optically. Similarly,
the topographic map of the ROI, shown in panel IV, features irregularities
in the sampling positions that correlate with the unablated sampling
positions (red marking) visible in the optical images.
Figure 2
(I, II) Optical image
of a G. hirsutum stem at 50-fold magnification,
pre- and post-LAESI-MSI, respectively.
(III) Three-dimensional rendering of the ROI, based on an acquired Z-stack of optical images taken post-LAESI-MSI. The spatial
distributions of m/z 273.08 (IV)
and 409.20 (V) were acquired at 100 μm lateral resolution in
our custom-built ion source, configured in the classic LAESI geometry
and putatively assigned to the [M – H]⊖ of
hemigossypolone and heliocide H1-4, respectively. The topographic
map (VI) was acquired by profilometry prior to LAESI-MSI and visualizes,
in gray scale, the height values for each sampling position of the
LAESI-MSI. The red marking indicates an area where surface curvature
interfered with the profilometry and thus laser ablation. All scale
bars represent a distance of 200 μm.
(I, II) Optical image
of a G. hirsutum stem at 50-fold magnification,
pre- and post-LAESI-MSI, respectively.
(III) Three-dimensional rendering of the ROI, based on an acquired Z-stack of optical images taken post-LAESI-MSI. The spatial
distributions of m/z 273.08 (IV)
and 409.20 (V) were acquired at 100 μm lateral resolution in
our custom-built ion source, configured in the classic LAESI geometry
and putatively assigned to the [M – H]⊖ of
hemigossypolone and heliocide H1-4, respectively. The topographic
map (VI) was acquired by profilometry prior to LAESI-MSI and visualizes,
in gray scale, the height values for each sampling position of the
LAESI-MSI. The red marking indicates an area where surface curvature
interfered with the profilometry and thus laser ablation. All scale
bars represent a distance of 200 μm.The spatial distributions of m/z 273.08 and 409.20 (panels IV and V), putatively assigned to hemigossypolone
and heliocide H1-4, respectively, exhibit the expected binary and
highly localized distribution within the black pigment glands.[27] Representative mass spectra for black pigment
glands as well as green tissue can be found in the Supporting Information (Figure S2).As a plant of the
Brassicaceae family, A. thaliana produces
glucosinolates as defensive metabolites.[28] These are distributed evenly, or with gradual changes,
in the plant’s leaves,[29,30] in contrast to the
binary distribution of compounds present in the black pigment glands
of G. hirsutum. We expected glucobrassicin
to have the most homogeneous distribution of the multiple glucosinolate
compounds present in A. thaliana leaves.
Any measured distribution was therefore expected to exhibit low pixel-to-pixel
variability. Representative results from LAESI-MSI experiments on A. thaliana leaves are shown in Figure . Panels II and III show the
spatial distributions of m/z 447.05
and 223.06, putatively assigned to glucobrassicin and sinapic acid,
respectively. Although the distributions shown in Figure visualize TIC-normalized intensity
values, to account for small fluctuations in the overall ion yield
of the electrospray, the high pixel-to-pixel variation in the measured
intensity values masks potential smaller changes in intensity that
would indicate gradual changes in metabolite distribution. The difference
in distribution of glucobrassicin (II) and sinapic acid (III) is the
absence of the latter in the midrib of the leaf, suggesting that stark
contrasts in metabolite distribution were still picked up. Representative
mass spectra acquired during LAESI-MSI on A. thaliana leaves can be found in the Supporting Information (Figure S3). The surprisingly high pixel-to-pixel variability sparked
our interest in the repeatability achievable with LAESI and our custom-built
ion sources.
Figure 3
(I) Optical image of an A. thaliana leaf taken pre LAESI-MSI, as well as the spatial distributions of m/z 447.05 (II) and 223.06 (III), assigned
putatively to the [M – H]⊖ of glucobrassicin
and sinapic acid, respectively. The visualized intensity values were
acquired at 200 μm lateral resolution in our custom-built ion
source configured in the classic LAESI geometry and TIC-normalized.
The scale bar represents a distance of 500 μm.
(I) Optical image of an A. thaliana leaf taken pre LAESI-MSI, as well as the spatial distributions of m/z 447.05 (II) and 223.06 (III), assigned
putatively to the [M – H]⊖ of glucobrassicin
and sinapic acid, respectively. The visualized intensity values were
acquired at 200 μm lateral resolution in our custom-built ion
source configured in the classic LAESI geometry and TIC-normalized.
The scale bar represents a distance of 500 μm.
Limit of Detection and Repeatability
Measurements of
the 13C6-Phe LODs of all three custom-built
LAESI ion source geometries and the LAESI DP-1000 ion source were
used to estimate how LAESI ion source geometry might influence sensitivity
under otherwise equal conditions. Table lists the determined LOD values, based on
the quadratic regression modeling and an S/N threshold of 4. Figure
S1 in the Supporting Information shows
the collected data points for all four ion sources tested. Transporting
the ablated sample as electrically neutral particles, as is the case
with the coaxial source geometry, seems to influence the LOD negatively.
In all cases, the observed signal variation increased significantly
with the concentration of 13C6-Phe, negatively
impacting the quality of the regression modeling, despite appropriate
variance correction and reflected in the confidence intervals. The
measured LOD values were therefore interpreted as estimates and not
taken at face value.
Table 1
Calculated 13C6-Phe Limit of Detection Values, Including Confidence
Intervals (p = 0.05) for All Four Ion Source Geometries
Tested and
the Achieved Laser Focus and Sample Volume
ion source geometry
LOD (μg mL–1)
laser focus (μm)
V (μL, sample)
ionization
chamber geometry
0.86(48)
100
2
classic
LAESI geometry
2.5(25)
100
2
coaxial
source geometry
32(30)
100
2
DP-1000 LAESI source
4.3(49)
300
20
The coefficient of
variation, cv, was
the parameter of choice to evaluate the repeatability. Figure , panel I displays the cv calculated from the experimental data acquired
by ion source geometry. Measurements using the classic LAESI geometry
are significantly less repeatable than experiments with the other
ion source geometries. The average coefficients calculated from the
raw data are 0.61, 0.32, 0.28, and 0.35 for the classic LAESI, ionization
chamber, DP-1000, and coaxial ionization geometries, respectively.
No change resulted when the measured 13C6-Phe
intensity values, either by TIC or leucine enkephalin, were normalized
as shown in Figure , panel II (ANOVA, p = 0.05). In general, a cv of 0.25 (calculated from data from 10 experiments)
represents a situation in which the standard deviation equals a quarter
of the mean. Under these circumstances, a signal response needs to
either double or be halved to be considered significantly different.
Although cv is derived from intensity
values, the same arguments holds true when considering concentrations
due to the relative and dimensionless nature of cv.
Figure 4
(I) Repeatability of sampling of 13C6-Phe
standard droplets (n = 10) in the classic LAESI,
coaxial ionization, and ionization chamber geometry, as well as the
DP-1000 ion source, expressed as the coefficients of variation of
the measured intensity values. The numbers above the brackets denote
the corresponding p-value of a pairwise t test. Normalization by TIC or lock mass (II) has no significant
influence on the coefficient of variation (ANOVA, p = 0.05).
(I) Repeatability of sampling of 13C6-Phe
standard droplets (n = 10) in the classic LAESI,
coaxial ionization, and ionization chamber geometry, as well as the
DP-1000 ion source, expressed as the coefficients of variation of
the measured intensity values. The numbers above the brackets denote
the corresponding p-value of a pairwise t test. Normalization by TIC or lock mass (II) has no significant
influence on the coefficient of variation (ANOVA, p = 0.05).
ESI Stability
In Figure , panels
I and II, the amount of average ESI current
and the range of ESI current drawn are shown for each ion source geometry,
respectively. In general, the average amount of ESI current drawn
by the classic LAESI and the DP-1000 source geometry was higher than
that drawn by the other two spatially more confined ion source geometries.
Furthermore, the amount of current drawn in both the classic LAESI
and the DP-1000 source geometry differed significantly (p < 0.01 and p < 0.001, respectively) between
the cv determination and control experiments
(no sample being presented); however, the observed trends are reversed.
The classic LAESI geometry drew more and the DP-1000 source drew less
ESI current in the cv determination experiments,
compared to the control experiments. No significant differences were
observed in the other two ion source geometries. In addition to the
average ESI current, the range of currents drawn was considered a
suitable parameter to assess the stability of ESI over the course
of the experiments. No significant differences were observed for any
ion source geometry between the experiments with ablation taking place
and the control experiments. It was therefore concluded that the ablation
events did not influence the long-term stability of the ESI.
Figure 5
(I) Average
electric current drawn by the electrospray during the
repeatability (blue) and the control experiments with no liquid standard
present in the source (red), per investigated ion source geometry.
In (II), the corresponding range of electric current drawn is shown
in the same color scheme as that used for (I).
(I) Average
electric current drawn by the electrospray during the
repeatability (blue) and the control experiments with no liquid standard
present in the source (red), per investigated ion source geometry.
In (II), the corresponding range of electric current drawn is shown
in the same color scheme as that used for (I).
Discussion
MSI is a relatively quantitative methodology.
Experimental parameters must remain constant over the course of an
experiment if results are to be comparable. We were therefore concerned
with the repeatability of our custom-built LAESI ion sources after
observing the unexpected pixel-to-pixel variability in the experiments
on A. thaliana.There are several
conceivable explanations for the observed variability, which fall
into three experimentally assessable groups. First, the variability
of measured intensity values was due to naturally occurring differences
of biological parameters, such as local metabolite concentrations,
water content, and tensile strength of the sampled tissue. Second,
the electrospray providing the ionization capabilities of the LAESI
ion source was not stable (the consequences of which having been studied
previously[31]). Third, the ion yield of
the ionization step was partially subject to randomness, resulting
from an inconsistent interaction between the ablation and ESI plumes.
To date, the third possibility has only rarely been considered.Although Stopka et al.[20] reported biologically
derived differences in local analyte concentrations being measured
in a fiber-based LAESI ion source, their measurements were obtained
from ablating a single cell. In the MSI experiments we reported here,
the average ablation mark removed a volume far larger than a single
cell. Even when significant differences in local concentrations may
have been present, any variation originating from different metabolite
concentrations in single cells was inevitably reduced through averaging
effects.Similarly, electrospray instability is not supported
as an explanation
for the observed variability by our data either. In our experiments,
the range of current drawn by the electrosprays of all investigated
ion sources remained approximately similar whether or not laser ablation
took place, suggesting that the ablation event does not lead to a
destabilization of the ESI plume. A randomness in the analytical volume
created by the overlapping ablation and ESI plumes, however, could
cause a fluctuating ion yield. Measured intensity values might then
vary on a pixel-by-pixel basis, depending on how well the ESI and
the ablation plume overlap.The unique possibility of LAESI
to directly sample liquids made
it possible to eliminate variability caused by biological parameters
entirely. The distribution of a (solvated) standard within a solution
can safely be assumed to be homogeneous, unlike the distribution of
standards in homogenates and sprayed-on targets used in most experiments
with MALDI or DESI sources. Sampling a droplet of a standard solution
repeatedly therefore truly means sampling the same concentration repeatedly.
The inclusion of the commercially available LAESI ion source controlled
against a possible bias introduced by the in-house construction of
the three other ion source geometries.In the end, the lack
of repeatability observed here would be of
little consequence in any kind of exploratory profiling experiments.
It limits, however, the usefulness of LAESI as an ionization technique
for MSI experiments to applications with very distinct spatial distributions
of metabolites. Studies of the transport of neutral particles in remote
LAESI geometries,[32] such as that of Dolatmoradi
et al.,[33] are therefore important for the
ongoing development of the LAESI method. The transmission geometry
of the optical system applied in that study, however, is unsuitable
for applications on samples with a thickness beyond that of a thin
section and with a three-dimensional surface topography, such as stems
and whole leaves.
Conclusion
As a technique, LAESI
offers a unique approach to ionization; it
holds great promise for application-rich fields with delicate samples,
such as chemical ecology, especially when combining profilometry of
the sample’s surface and topographically guided laser ablation.
More work on the interaction between ablated sample material and the
ESI plume will be necessary, however, before its advantages are evident
in routine MSI experiments.
Authors: Olga S Ovchinnikova; Maxim P Nikiforov; James A Bradshaw; Stephen Jesse; Gary J Van Berkel Journal: ACS Nano Date: 2011-06-06 Impact factor: 15.881
Authors: Laith Z Samarah; Rikkita Khattar; Tina H Tran; Sylwia A Stopka; Christine A Brantner; Paola Parlanti; Dušan Veličković; Jared B Shaw; Beverly J Agtuca; Gary Stacey; Ljiljana Paša-Tolić; Nikola Tolić; Christopher R Anderton; Akos Vertes Journal: Anal Chem Date: 2020-05-04 Impact factor: 6.986
Authors: Shane R Ellis; Simon H Brown; Marc In Het Panhuis; Stephen J Blanksby; Todd W Mitchell Journal: Prog Lipid Res Date: 2013-04-24 Impact factor: 16.195
Authors: Laine R Compton; Brent Reschke; Jordan Friend; Matthew Powell; Akos Vertes Journal: Rapid Commun Mass Spectrom Date: 2015-01-15 Impact factor: 2.419
Authors: Jeffrey M Spraggins; David G Rizzo; Jessica L Moore; Michael J Noto; Eric P Skaar; Richard M Caprioli Journal: Proteomics Date: 2016-05-10 Impact factor: 3.984