Literature DB >> 21639403

Combined atomic force microscope-based topographical imaging and nanometer-scale resolved proximal probe thermal desorption/electrospray ionization-mass spectrometry.

Olga S Ovchinnikova1, Maxim P Nikiforov, James A Bradshaw, Stephen Jesse, Gary J Van Berkel.   

Abstract

Nanometer- scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nanothermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 °C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 × 2 array of spots, with 2 μm spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (∼2 × 10(6) nm(3)), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in an automated fashion submicrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21639403     DOI: 10.1021/nn200939e

Source DB:  PubMed          Journal:  ACS Nano        ISSN: 1936-0851            Impact factor:   15.881


  8 in total

1.  Microscopy ambient ionization top-down mass spectrometry reveals developmental patterning.

Authors:  Cheng-Chih Hsu; Nicholas M White; Marito Hayashi; Eugene C Lin; Tiffany Poon; Indroneal Banerjee; Ju Chen; Samuel L Pfaff; Eduardo R Macagno; Pieter C Dorrestein
Journal:  Proc Natl Acad Sci U S A       Date:  2013-08-22       Impact factor: 11.205

2.  Probe-Substrate Distance Control in Desorption Electrospray Ionization.

Authors:  Tyler J Yarger; Elizabeth M Yuill; Lane A Baker
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-27       Impact factor: 3.109

Review 3.  Label-free molecular imaging of the kidney.

Authors:  Boone M Prentice; Richard M Caprioli; Vincent Vuiblet
Journal:  Kidney Int       Date:  2017-07-24       Impact factor: 10.612

4.  Towards Practical Endoscopic Mass Spectrometry.

Authors:  Lee Chuin Chen; Kentaro Yoshimura; Satoshi Ninomiya; Sen Takeda; Kenzo Hiraoka
Journal:  Mass Spectrom (Tokyo)       Date:  2017-08-23

5.  Nanopipettes: probes for local sample analysis.

Authors:  Anumita Saha-Shah; Anna E Weber; Jonathan A Karty; Steven J Ray; Gary M Hieftje; Lane A Baker
Journal:  Chem Sci       Date:  2015-04-13       Impact factor: 9.825

6.  Tip-enhanced ablation and ionization mass spectrometry for nanoscale chemical analysis.

Authors:  Zhisen Liang; Shudi Zhang; Xiaoping Li; Tongtong Wang; Yaping Huang; Wei Hang; Zhilin Yang; Jianfeng Li; Zhongqun Tian
Journal:  Sci Adv       Date:  2017-12-08       Impact factor: 14.136

7.  Automated 3D Sampling and Imaging of Uneven Sample Surfaces with LA-REIMS.

Authors:  Sylvia P Nauta; Pascal Huysmans; Gabriëlle J M Tuijthof; Gert B Eijkel; Martijn Poeze; Tiffany Porta Siegel; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2021-12-09       Impact factor: 3.109

8.  Influence of Ion Source Geometry on the Repeatability of Topographically Guided LAESI-MSI.

Authors:  Benjamin Bartels; Aleš Svatoš
Journal:  J Am Soc Mass Spectrom       Date:  2022-01-12       Impact factor: 3.109

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.