Quantitative compressive optical coherence elastography using structural OCT imaging and optical palpation to measure soft contact lens mechanical properties.

Zachery Quince1, David Alonso-Caneiro1, Scott A Read1, Michael J Collins1.   

Abstract

In this study, the principle of 'optical palpation' was applied to a compression optical coherence elastography (OCE) method using spectral domain optical coherence tomography (OCT). Optical palpation utilizes a compliant transparent material of known mechanical properties, which acts as a stress sensor, in order to derive the mechanical properties of a sample material under examination. This technique was applied to determine the mechanical properties of soft contact lenses, with one lens being used as the compliant stress sensor and the other as the sample under investigation to extract the mechanical properties. This compliant stress sensor allowed for the stress of the compression to be measured without the use of a force sensor. The strain of the materials was measured through an automatic boundary segmentation that tracks the material thickness (of the sensor and the sample) during compression through sequential structural OCT images. A total of five contact lens combinations were tested, using three separate commercially available contact lenses with unique mechanical properties. Various combinations of contact lens materials were used to further validate the technique. The Young's modulus derived from this method was compared to nominal manufacturer's values. Both accuracy and repeatability were assessed, with highly accurate measurements obtained, with a percentage difference between the nominal and experimentally derived Young's modulus being less than 6% for all the tested combinations as well as providing a Young's modulus that was not statistically significant different (p > 0.01) to the nominal value. The results demonstrate the potential of optical palpation in OCE to accurately measure the mechanical properties of a material without the use of sophisticated electronics to capture the stress of the sample. These findings have potential to be translated into a method for tissue mechanical testing with ex vivo and in vivo clinical applications.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2021        PMID: 35003835      PMCID: PMC8713674          DOI: 10.1364/BOE.441547

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  19 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Method for optical coherence elastography of the cornea.

Authors:  Matthew R Ford; William J Dupps; Andrew M Rollins; Roy A Sinha; Zhilin Hu
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

3.  Automatic anterior chamber angle assessment for HD-OCT images.

Authors:  Jing Tian; Pina Marziliano; Mani Baskaran; Hong-Tym Wong; Tin Aung
Journal:  IEEE Trans Biomed Eng       Date:  2011-08-30       Impact factor: 4.538

4.  Static compression optical coherence elastography to measure the mechanical properties of soft contact lenses.

Authors:  Zachery Quince; David Alonso-Caneiro; Scott A Read; Michael J Collins
Journal:  Biomed Opt Express       Date:  2021-03-02       Impact factor: 3.732

5.  The effect of soft contact lens care products on lens modulus.

Authors:  G Young; R Garofalo; O Harmer; S Peters
Journal:  Cont Lens Anterior Eye       Date:  2010-07-31       Impact factor: 3.077

6.  Mechanical Properties of Contact Lens Materials.

Authors:  Eon Kim; Mou Saha; Klaus Ehrmann
Journal:  Eye Contact Lens       Date:  2018-11       Impact factor: 2.018

7.  Refractive-index measurement and inverse correction using optical coherence tomography.

Authors:  Jenny Stritzel; Maik Rahlves; Bernhard Roth
Journal:  Opt Lett       Date:  2015-12-01       Impact factor: 3.776

8.  Noncontact Elastic Wave Imaging Optical Coherence Elastography for Evaluating Changes in Corneal Elasticity Due to Crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Shang Wang; Zhaolong Han; Achuth Nair; Salavat R Aglyamov; Michael D Twa; Kirill V Larin
Journal:  IEEE J Sel Top Quantum Electron       Date:  2015-12-17       Impact factor: 4.544

9.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation.

Authors:  Stephanie J Chiu; Xiao T Li; Peter Nicholas; Cynthia A Toth; Joseph A Izatt; Sina Farsiu
Journal:  Opt Express       Date:  2010-08-30       Impact factor: 3.894

Review 10.  Optical coherence elastography in ophthalmology.

Authors:  Mitchell A Kirby; Ivan Pelivanov; Shaozhen Song; Łukasz Ambrozinski; Soon Joon Yoon; Liang Gao; David Li; Tueng T Shen; Ruikang K Wang; Matthew O'Donnell
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.