Literature DB >> 21880568

Automatic anterior chamber angle assessment for HD-OCT images.

Jing Tian1, Pina Marziliano, Mani Baskaran, Hong-Tym Wong, Tin Aung.   

Abstract

Angle-closure glaucoma is a major blinding eye disease and could be detected by measuring the anterior chamber angle in the human eyes. High-definition OCT (Cirrus HD-OCT) is an emerging noninvasive, high-speed, and high-resolution imaging modality for the anterior segment of the eye. Here, we propose a novel algorithm which automatically detects a new landmark, Schwalbe's line, and measures the anterior chamber angle in the HD-OCT images. The distortion caused by refraction is corrected by dewarping the HD-OCT images, and three biometric measurements are defined to quantitatively assess the anterior chamber angle. The proposed algorithm was tested on 40 HD-OCT images of the eye and provided accurate measurements in about 1 second.

Entities:  

Mesh:

Year:  2011        PMID: 21880568     DOI: 10.1109/TBME.2011.2166397

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  11 in total

1.  Quantitative compressive optical coherence elastography using structural OCT imaging and optical palpation to measure soft contact lens mechanical properties.

Authors:  Zachery Quince; David Alonso-Caneiro; Scott A Read; Michael J Collins
Journal:  Biomed Opt Express       Date:  2021-11-04       Impact factor: 3.732

2.  Learning ECOC Code Matrix for Multiclass Classification with Application to Glaucoma Diagnosis.

Authors:  Xiaolong Bai; Swamidoss Issac Niwas; Weisi Lin; Bing-Feng Ju; Chee Keong Kwoh; Lipo Wang; Chelvin C Sng; Maria C Aquino; Paul T K Chew
Journal:  J Med Syst       Date:  2016-01-21       Impact factor: 4.460

3.  Automatic Classification of Anterior Chamber Angle Using Ultrasound Biomicroscopy and Deep Learning.

Authors:  Guohua Shi; Zhenying Jiang; Guohua Deng; Guangxing Liu; Yuan Zong; Chunhui Jiang; Qian Chen; Yi Lu; Xinhuai Sun
Journal:  Transl Vis Sci Technol       Date:  2019-08-19       Impact factor: 3.283

4.  Analysis of Schwalbe's Line (Limbal Smooth Zone) by Scanning Electron Microscopy and Optical Coherence Tomography in Human Eye Bank Eyes.

Authors:  Mark P Breazzano; Michael Fikhman; Jerrold L Abraham; Ann E Barker-Griffith
Journal:  J Ophthalmic Vis Res       Date:  2013-01

5.  Anterior eye tissue morphology: Scleral and conjunctival thickness in children and young adults.

Authors:  Scott A Read; David Alonso-Caneiro; Stephen J Vincent; Alexander Bremner; Annabel Fothergill; Brittney Ismail; Rebecca McGraw; Charlotte J Quirk; Elspeth Wrigley
Journal:  Sci Rep       Date:  2016-09-20       Impact factor: 4.379

6.  Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics.

Authors:  Handan Akil; Anna Dastiridou; Kenneth Marion; Brian A Francis; Vikas Chopra
Journal:  BMC Ophthalmol       Date:  2017-03-23       Impact factor: 2.209

7.  Unsupervised feature extraction of anterior chamber OCT images for ordering and classification.

Authors:  Pablo Amil; Laura González; Elena Arrondo; Cecilia Salinas; J L Guell; Cristina Masoller; Ulrich Parlitz
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

8.  Automatic Identification and Representation of the Cornea-Contact Lens Relationship Using AS-OCT Images.

Authors:  Pablo Cabaleiro; Joaquim de Moura; Jorge Novo; Pablo Charlón; Marcos Ortega
Journal:  Sensors (Basel)       Date:  2019-11-21       Impact factor: 3.576

9.  Automatic Anterior Chamber Angle Classification Using Deep Learning System and Anterior Segment Optical Coherence Tomography Images.

Authors:  Wanyue Li; Qian Chen; Chunhui Jiang; Guohua Shi; Guohua Deng; Xinghuai Sun
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

10.  Anterior Chamber Angle Shape Analysis and Classification of Glaucoma in SS-OCT Images.

Authors:  Soe Ni Ni; J Tian; Pina Marziliano; Hong-Tym Wong
Journal:  J Ophthalmol       Date:  2014-08-05       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.