Mechanical Properties of Contact Lens Materials.

Eon Kim1, Mou Saha, Klaus Ehrmann.   

Abstract

OBJECTIVES: To evaluate the mechanical properties of commonly available soft contact lens materials and compare results using custom-built MicroTensometer.
METHODS: The Young modulus, parameters for stress relaxation, and toughness of 18 types of single vision soft contact lenses were measured using custom-built MicroTensometer. Five lenses of each type were soaked in standard phosphate buffered saline and measured at a temperature of 35°C. Each lens was flattened and sliced into a rectangular strip sample using two parallel blades.
RESULTS: The Acuvue Moist 1-Day and SofLens Daily lenses measured lowest moduli, whereas Air Optix Night & Day Aqua and Premio measured the highest. The measured moduli for silicone hydrogel materials were generally higher compared with the hydrogels except for Dailies AquaComfort Plus. The exponential curve fitted over the decay in stress showed a consistent time constant of approximately 10 sec for most lens types measured. However, the amplitude constant varied from 2.84% for SofLens Daily to 22.39% for Acuvue TruEye 1-Day. The toughness results showed that Dailies AquaComfort Plus is strong but not necessarily tough.
CONCLUSIONS: The mechanical properties of commonly prescribed soft contact lens materials were measured using a dedicated instrument. Its reliability was demonstrated, and modulus results were compared against published data from manufacturers and other research groups. Agreement was generally good, with only a few exceptions exceeding 15% difference. The more recently released silicone hydrogel lens types have reduced modulus, approaching that of medium or high water content hydrogel materials.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29116965     DOI: 10.1097/ICL.0000000000000442

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  3 in total

1.  Quantitative compressive optical coherence elastography using structural OCT imaging and optical palpation to measure soft contact lens mechanical properties.

Authors:  Zachery Quince; David Alonso-Caneiro; Scott A Read; Michael J Collins
Journal:  Biomed Opt Express       Date:  2021-11-04       Impact factor: 3.732

2.  Atorvastatin-Eluting Contact Lenses: Effects of Molecular Imprinting and Sterilization on Drug Loading and Release.

Authors:  Ana F Pereira-da-Mota; María Vivero-Lopez; Ana Topete; Ana Paula Serro; Angel Concheiro; Carmen Alvarez-Lorenzo
Journal:  Pharmaceutics       Date:  2021-04-22       Impact factor: 6.321

3.  Evaluation of Personality Features and Mental State of Keratoconus Patients.

Authors:  Mehmet Gokhan Aslan; Mert Besenek; Hasan Akgoz; Muhammed Fatih Satılmaz; Cicek Hocaoglu
Journal:  Beyoglu Eye J       Date:  2021-12-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.