| Literature DB >> 34991505 |
Junren Kang1, Hailong Li1, Xiaodong Shi1, Enling Ma1, Wei Chen2.
Abstract
BACKGROUND: Malnutrition is common in cancer patients. The NUTRISCORE is a newly developed cancer-specific nutritional screening tool and was validated by comparison with the Patient-Generated Subjective Global Assessment (PG-SGA) and Malnutrition Screening Tool (MST) in Spain. We aimed to evaluate the performance of the NUTRISCORE, MST, and PG-SGA in estimating the risk of malnutrition in Chinese cancer patients.Entities:
Keywords: Cancer patients; Malnutrition; Malnutrition screening tool (MST); NUTRISCORE; Patient-generated subjective global assessment (PG-SGA)
Mesh:
Year: 2022 PMID: 34991505 PMCID: PMC8740059 DOI: 10.1186/s12885-021-09135-2
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Patient characteristics
| Characteristics | n (%) |
|---|---|
| 55.9 + 11.8 | |
| Range | 19–92 |
| Male | 475 (47.5) |
| Female | 525 (52.5) |
| Primary school | 210 (21.0) |
| Secondary Education | 577 (57.7) |
| College education | 213 (21.3) |
| Lung cancer | 344 (34.4) |
| Breast cancer | 196 (19.6) |
| Gastric cancer | 78 (7.8) |
| Liver cancer | 39 (3.9) |
| Esophageal cancer | 28 (2.8) |
| Colorectal cancer | 83 (8.3) |
| Cervical cancer | 24 (2.4) |
| Ovarian cancer | 28 (2.8) |
| Leukemia | 131 (13.1) |
| Lymphoma | 39 (3.9) |
| Others | 10 (0.1) |
| 60 (6.1) | |
| 29 (2.9) | |
| 367 (36.7) | |
| 450 (45.0) | |
BMI Body Mass Index, MST Malnutrition Screening Tool, PG-SGA Patient-Generated Subjective Global Assessment
Performance comparison
| NUTRISCORE | MST | |
|---|---|---|
| Sensitivity % (95% CI) | 6.2 (4.2–8.9) | 50.9 (46.2–55.9) |
| Specificity % (95% CI) | 99.8 (98.8–100) | 74.9 (71.0–78.4) |
| Positive predictive value % (95% CI) | 96.6 (80.4–99.8) | 62.4 (57.2–67.3) |
| Negative predictive value % (95% CI) | 56.5 (53.4–59.7) | 65.1 (61.2–68.8) |
| Area under the ROC curve | 0.53 (0.49–0.57) | 0.63 (0.59–0.66) |
| Kappa | 0.066* | 0.262* |
MST Malnutrition Screening Tool, ROC receiver operating characteristic. *P < 0.05
Fig. 1Receiver operating characteristic curves of the NUTRISCORE, MST and PG-SGA