Literature DB >> 3498805

Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques.

S H Manglos1, R J Jaszczak, C E Floyd, L J Hahn, K L Greer, R E Coleman.   

Abstract

A quantitative study of nonisotropic attenuation in SPECT imaging is presented. The study includes a case where the spatial distribution of the attenuation coefficient is nonuniform, as well as a case where the photon path length in the attenuating medium is variable as a function of direction. The effects are studied using phantoms with known source activity and density distributions. Reconstructed images of the phantoms with and without attenuation compensation are compared with the source distribution. Three methods are used to provide partial attenuation compensation, using effective attenuation coefficients. These coefficients include some of the effects of photon scatter, but scatter is not explicitly treated. One attenuation compensation method involves a multiplicative postprocessing correction using an assumed constant attenuation coefficient. A modification of this technique is implemented using the correct nonuniform attenuation map to determine the multiplication factors. A single-iteration technique is used to provide a more complete compensation. The results indicate that nonuniform attenuation can produce significant distortion in line spread functions and in larger distributed sources. This distortion can alter volume determinations, quantitation measurements, and the shape of small objects, and can cause misplacement of counts into regions of low density. The distortion cannot be eliminated by the multiplicative postprocessing correction, but the single-iteration technique can significantly decrease the distortion.

Mesh:

Year:  1987        PMID: 3498805

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

1.  Attenuation smear: a 'paradoxical' increase in counts due to attenuation artifact.

Authors:  C L Hansen; M Kramer
Journal:  Int J Card Imaging       Date:  2000-12

2.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

3.  Quantitative single photon emission tomography: verification for sources in an elliptical water phantom.

Authors:  M H Ljungberg; M A King; S E Strand
Journal:  Eur J Nucl Med       Date:  1992

4.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

Review 5.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

6.  A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents.

Authors:  M A King; W Xia; D J deVries; T S Pan; B J Villegas; S Dahlberg; B M Tsui; M H Ljungberg; H T Morgan
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

Review 7.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

8.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

9.  Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies.

Authors:  D L Bailey; M Robinson; S R Meikle; P T Bye
Journal:  Eur J Nucl Med       Date:  1996-03

10.  Experimental validation of a new quantitative method for the analysis of infarct size by cardiac perfusion tomography (SPECT).

Authors:  L Mortelmans; J Nuyts; J Vanhaecke; A Verbruggen; M De Roo; H De Geest; P Svetens; F Van de Werf
Journal:  Int J Card Imaging       Date:  1993-09
View more