| Literature DB >> 34961542 |
Yuzhou Wu1,2, Shunhua Zhang3,4, Yong Zhong1,2, Ailing Bian1,2, Yang Zhang1,2, Zaowen Wang1,2.
Abstract
PURPOSE: To assess the accuracy of biometric parameters measured by anterior segment optical coherence tomography (AS-OCT) and partial coherence interferometry (PCI) in prediction of effective lens position (ELP) compared with previous formulas in PACG patients.Entities:
Keywords: Anterior segment optical coherence tomography; Effective Lens position; Formula; Primary angle closure Glaucoma
Mesh:
Year: 2021 PMID: 34961542 PMCID: PMC8711180 DOI: 10.1186/s12886-021-02213-w
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Schematic diagram of the parameters used in the new formula pictured by AS-OCT, CT = corneal thickness; ELP = effective lens position; IOL = intraocular lens; LV = lens vault; post-ACD = postoperative anterior chamber depth; pre-ACD = preoperative anterior chamber depth; SSD = scleral spur distance; SSW = scleral spur width
Fig. 2Selection criteria used in this study
Preoperative and Postoperative Measurements in Training and Validation Sets
| Training Set ( | Validation Set ( | ||
|---|---|---|---|
| Measures | |||
| Gender (Female: Male) | 71:14 | 27:9 | NA |
| Age (year) | 69.38 (9.57) | 69.47 (9.35) | 0.96 |
| AOD 500 (mm) | 0.07 (0.05) | 0.08 (0.07) | 0.56 |
| AOD 750 (mm) | 0.12 (0.07) | 0.13 (0.10) | 0.76 |
| TISA 500 (mm) | 0.03 (0.02) | 0.03 (0.02) | 0.55 |
| TISA 750 (mm) | 0.05 (0.04) | 0.06 (0.04) | 0.57 |
| SSA (degree) | 7.78 (5.58) | 8.43 (7.07) | 0.60 |
| Pre-ACD (mm) | 1.79 (0.30) | 1.75 (0.31) | 0.49 |
| Post-ACD (mm) | 3.49 (0.27) | 3.45 (0.27) | 0.44 |
| Preoperative SSD (mm) | 2.87 (0.22) | 2.82 (0.22) | 0.20 |
| Postoperative SSD (mm) | 2.94 (0.30) | 2.88 (0.22) | 0.23 |
| Preoperative SSW (mm) | 11.19 (0.39) | 11.14 (0.37) | 0.49 |
| Postoperative SSW (mm) | 11.19 (0.39) | 11.13 (0.44) | 0.44 |
| Preoperative CT (mm) | 0.54 (0.05) | 0.54 (0.05) | 0.36 |
| Postoperative CT (mm) | 0.55 (0.06) | 0.55 (0.05) | 0.44 |
| LV (mm) | 1.09 (0.30) | 1.05 (0.36) | 0.54 |
| AL (mm) | 22.31 (0.85) | 22.21 (0.94) | 0.52 |
| K (diopters) | 44.64 (1.60) | 44.62 (1.76) | 0.94 |
| IOL Thickness (mm) | 0.90 (0.14) | 0.89 (0.11) | 0.63 |
| Measured ELP (mm) | 4.48 (0.25) | 4.43 (0.26) | 0.36 |
AL Axial length, AOD Angle opening distance, CT Corneal thickness, ELP Effective lens position, IOL Intraocular lens, LV Lens vault, NA Not available, post-ACD Postoperative anterior chamber depth, pre-ACD Preoperative anterior chamber depth, SD Standard deviation, SSA Scleral spur angle, SSD Scleral spur distance, SSW Scleral spur width, TISA Trabecular iris surface area
Significant difference is noted at P < 0.05
Multiple linear regression analysis of post-ACD in training set (N = 85)
| R2 | |
|---|---|
| Pre-ACD, AL | 0.19 |
| AL, K | 0.25 |
| SSD | 0.29 |
| SSD, AL | 0.41 |
| SSD, AL, SSW | 0.49 |
| SSD, AL, SSW, Pre-ACD, K | 0.49 |
AL Axial length, K Corneal power, post-ACD Postoperative anterior chamber depth, pre-ACD Preoperative anterior chamber depth, SSD Scleral spur distance, SSW Scleral spur width
One-way analysis of variance and Pearson correlation analysis in validation set (N = 36)
| Mean (95% CI) | MAE (SD) | R2 | ||
|---|---|---|---|---|
| Measured ELP | 4.43 (4.34-4.52) | |||
| New Formula | 4.41 (4.35-4.48) | 0.15 (0.11) | 0.50 | 0.9947 |
| 2016 Formula | 4.58 (4.53-4.64) | 0.19 (0.18) | 0.34 | 0.0013 |
| Holladay 1 | 5.04 (4.94-5.14) | 0.62 (0.30) | 0.12 | < 0.0001 |
| SRK/T | 5.01 (4.92-5.09) | 0.58 (0.30) | 0.11 | < 0.0001 |
| Haigis | 4.24 (4.18-4.30) | 0.27 (0.21) | 0.06 | < 0.0001 |
MAE Mean absolute error, SD Standard deviation, SRK/T Sanders-Retzlaff-Kraff theoretic, ELP Effective lens position, CI Confidence interval; 2016 Formula: refers to the formula released in Goto S, et al. [16]
Fig. 3Scatter diagram showing the relativity between measured ELP and ELP predicted by our formula in validation set (n = 36)
Fig. 4One-way ANOVA analysis in validation set (N = 36). Box-and-whisker plot displaying the comparison of Measured Effective Lens Position (ELP) and prediction ELP by our new formula, formula introduced by Goto S et al. in 2016 [16](2016 Formula), Holladay 1, Sanders-Retzlaff-Kraff theoretic (SRK/T) and Haigis formulas. ns = not significant. * = P < 0.05