Literature DB >> 3492880

Mammographic density and physical assessment of the breast.

C A Swann, D B Kopans, K A McCarthy, G White, D A Hall.   

Abstract

We studied the relationship between the radiographic density of the breast as measured by parenchymal pattern vs age, breast size, thickness after compression, and compressibility. Two hundred consecutive women were evaluated. None of the three parameters or the patient's age correlated with the degree of radiographic density. Although more older women had lucent parenchyma, 37% of women more than 50 years of age had dense patterns. Thus, these factors cannot be used to predict radiographic density. Phototiming is required to maintain image quality, and only a test exposure can accurately predict breast density.

Entities:  

Mesh:

Year:  1987        PMID: 3492880     DOI: 10.2214/ajr.148.3.525

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

Review 1.  Breast cancer screening in the era of density notification legislation: summary of 2014 Massachusetts experience and suggestion of an evidence-based management algorithm by multi-disciplinary expert panel.

Authors:  Phoebe E Freer; Priscilla J Slanetz; Jennifer S Haas; Nadine M Tung; Kevin S Hughes; Katrina Armstrong; A Alan Semine; Susan L Troyan; Robyn L Birdwell
Journal:  Breast Cancer Res Treat       Date:  2015-08-20       Impact factor: 4.872

2.  Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

Authors:  Q Le Huy; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

Review 3.  Risk-based Breast Cancer Screening: Implications of Breast Density.

Authors:  Christoph I Lee; Linda E Chen; Joann G Elmore
Journal:  Med Clin North Am       Date:  2017-07       Impact factor: 5.456

4.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

5.  Effective radiation attenuation calibration for breast density: compression thickness influences and correction.

Authors:  John J Heine; Ke Cao; Jerry A Thomas
Journal:  Biomed Eng Online       Date:  2010-11-16       Impact factor: 2.819

6.  Evaluation on Phantoms of the Feasibility of a Smart Bra to Detect Breast Cancer in Young Adults.

Authors:  Marie-Valérie Moreno; Edouard Herrera
Journal:  Sensors (Basel)       Date:  2019-12-12       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.