| Literature DB >> 34906224 |
Frida Björkman1,2, Örjan Ekblom3,4, Elin Ekblom-Bak3,4, Tony Bohman3,4.
Abstract
BACKGROUND: The purpose of the present study was to examine the ability of a submaximal cycling test to detect longitudinal changes in maximal oxygen uptake (VO2max) and examine the conformity between changes in measured and estimated VO2max over a time span of 5-8 years.Entities:
Keywords: Cycle ergometer test; Estimation; Fitness; Maximal oxygen uptake
Year: 2021 PMID: 34906224 PMCID: PMC8670613 DOI: 10.1186/s13102-021-00387-w
Source DB: PubMed Journal: BMC Sports Sci Med Rehabil ISSN: 2052-1847
Subject characteristics at baseline test and follow-up test
| Baseline test | Follow-up test | n |
| |
|---|---|---|---|---|
| Age (years) | 42.8 (11.1) | 48.4 (11.0) | 35 | < 0.001 |
| Height (cm) | 177.0 (10.5) | 176.8 (10.4) | 35 | 0.21 |
| Body Mass (kg) | 73.1 (12.3) | 73.5 (12.3) | 35 | 0.48 |
| Measured VO2max (L/min) | 3.65 (0.91) | 3.64 (0.89) | 35 | 0.91 |
| Measured VO2max (mL/kg/min) | 49.7 (8.2) | 49.5 (8.4) | 35 | 0.76 |
| Estimated VO2max (L/min) | 3.56 (0.93) | 3.47 (0.91) | 35 | 0.05 |
| Estimated VO2max (mL/kg/min) | 48.5 (9.0) | 47.2 (8.9) | 35 | 0.04 |
| VO2 at standard work rate (L/min) | 0.82 (0.11) | 0.81 (0.18) | 26a | 0.84 |
| HR at standard work rate (bpm) | 82.4 (12.2) | 81.9 (11.7) | 35 | 0.62 |
| Maximal HR (bpm) | 184.8 (14.6) | 181.0 (14.4) | 34b | < 0.001 |
| ΔHR/ΔPO | 0.41 (0.12) | 0.39 (0.12) | 35 | 0.08 |
All values are presented as means with standard deviation (SD)
VO2, Oxygen uptake; HR, heart rate; beats/min, beats per minute; ΔHR/ΔPO, change in heart rate/change in power output
*p-value for difference between baseline test and follow-up test
aMeasurements of VO2 at standard work rate was conducted in a subsample of the baseline tests, and the value was missing for nine of the re-recruited subjects in the present study
bOne subject had a missing maximal HR registration due to technical difficulties with the heart rate monitor during the final stages of the maximal running test
Fig. 1Change between the baseline test and the follow-up test in measured VO2max (y-axis) and estimated VO2max from the EB test (x-axis). Solid line: correlation. Dashed line: Line of identity. r = Pearson’s coefficient of correlation, R2 = coefficient of determination, 95% CI 95% confidence interval
Fig. 2Error at the baseline test (y-axis) and error at the follow-up test (x-axis). Solid line: correlation. Dashed line: Line of identity. r = Pearson’s coefficient of correlation, R2 = coefficient of determination, 95% CI 95% confidence interval
Fig. 3Bland Altman plots, including limits of agreement, for estimated and measured VO2max (L/min) at the baseline tests (left) and at the follow-up tests (right). Mean VO2max = (estimated + measured)/2. Black line: mean difference. Dashed line: ± 1.96 * SD