Frida Björkman 1 , Andrea Eggers 1 , Adam Stenman 1 , Tony Bohman 2 , Björn Ekblom 1 , Örjan Ekblom 1 . Show Affiliations »
Abstract
AIM: This study assessed the validity and reliability of the Ekblom-Bak (EB) submaximal cycle test in adolescents and identified any sex- or maturity-related factors for prediction errors. METHODS: We recruited 50 healthy subjects through a public announcement in Stockholm, Sweden, in 2016. The 27 boys and 23 girls were aged 10-15 years and in Tanner stages I-IV. They performed an EB test and incremental treadmill running test for direct measurement of maximal oxygen uptake (VO2 max). RESULTS: The estimation error of VO2 max was 0.09 L/min. The correlation (r) was 0.86, and the standard error of the estimate (SEE) was 0.29 L/min. The largest overestimation was seen in prepubertal boys (0.49 L/min). The best precision of the EB test was achieved when boys in Tanner stages I and II were re-calculated using the prediction equation developed for adult women. This yielded a mean difference of -0.05 L/min, r = 0.92 and SEE 0.23 L/min, in the entire sample. The prediction error was lowered in boys, but not girls, with increasing pubertal maturity. CONCLUSION: The EB test was reasonably valid in adolescents, seemed to be related to sex and maturity status, and our findings support its use. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
AIM: This study assessed the validity and reliability of the Ekblom-Bak (EB) submaximal cycle test in adolescents and identified any sex- or maturity-related factors for prediction errors. METHODS: We recruited 50 healthy subjects through a public announcement in Stockholm, Sweden, in 2016. The 27 boys and 23 girls were aged 10-15 years and in Tanner stages I-IV. They performed an EB test and incremental treadmill running test for direct measurement of maximal oxygen uptake (VO2 max). RESULTS: The estimation error of VO2 max was 0.09 L/min. The correlation (r) was 0.86, and the standard error of the estimate (SEE) was 0.29 L/min. The largest overestimation was seen in prepubertal boys (0.49 L/min). The best precision of the EB test was achieved when boys in Tanner stages I and II were re-calculated using the prediction equation developed for adult women . This yielded a mean difference of -0.05 L/min, r = 0.92 and SEE 0.23 L/min, in the entire sample. The prediction error was lowered in boys , but not girls , with increasing pubertal maturity. CONCLUSION: The EB test was reasonably valid in adolescents, seemed to be related to sex and maturity status, and our findings support its use. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Entities: Chemical
Species
Keywords:
Ergometry; Exercise test; Maximal oxygen uptake; Physical fitness; Sexual maturation
Mesh: See more »
Year: 2017
PMID: 28925577 DOI: 10.1111/apa.14080
Source DB: PubMed Journal: Acta Paediatr ISSN: 0803-5253 Impact factor: 2.299