Abstract

Tomographic reconstruction for single photon emission computed tomography (SPECT) with simultaneous compensation for attenuation, scatter, and distance dependent collimator resolution is provided by an Inverse Monte Carlo (IMOC) reconstruction algorithm. A detection probability matrix is formed by Monte Carlo solution to the photon transport equation for SPECT acquisition from a unit source activity in each reconstruction source voxel. The measured projection vector will equal the product of this detection probability matrix with the unknown source distribution vector. The resulting large, nonsparse system of equations is solved for the source distribution using an iterative Maximum Likelihood EM estimator. Reconstruction of experimentally acquired projections from phantoms shows quantitative compensation for scatter and attenuation. Comparison with filtered backprojection (FBP) reconstruction shows an improvement in resolution recovery, contrast, and signal-to-noise for the IMOC algorithm. Reconstruction of clinical studies shows improved contrast, structural resolution, and noise characteristics.

Mesh:

Year:  1986        PMID: 3489822

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  15 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

Review 2.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

3.  Bayesian image reconstruction for emission tomography incorporating Good's roughness prior on massively parallel processors.

Authors:  M I Miller; B Roysam
Journal:  Proc Natl Acad Sci U S A       Date:  1991-04-15       Impact factor: 11.205

4.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

5.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

Review 6.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

7.  Direct reconstruction of single-photon emission computed tomography images using retained matrix elements.

Authors:  J P Pratt; J L Lear
Journal:  J Digit Imaging       Date:  1997-02       Impact factor: 4.056

8.  Iterative reconstruction of thyroidal SPECT images.

Authors:  W Eschner; M Bähre; H Luig
Journal:  Eur J Nucl Med       Date:  1987

9.  Improvement of quantification in SPECT studies by scatter and attenuation compensation.

Authors:  J Mas; B Ben Younes; R Bidet
Journal:  Eur J Nucl Med       Date:  1989

Review 10.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11