Kaibao Sun1, Zheng Zhong1,2, Guangyu Dan1,2, Muge Karaman1,2, Qingfei Luo1, Xiaohong Joe Zhou1,2,3. 1. Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA. 2. Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA. 3. Departments of Radiology and Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, Illinois, USA.
Abstract
PURPOSE: This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS: The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION: This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.
PURPOSE: This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS: The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION: This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.
Authors: Emine Ulku Saritas; Charles H Cunningham; Jin Hyung Lee; Eric T Han; Dwight G Nishimura Journal: Magn Reson Med Date: 2008-08 Impact factor: 4.668
Authors: Stefan Posse; Elena Ackley; Radu Mutihac; Jochen Rick; Matthew Shane; Cristina Murray-Krezan; Maxim Zaitsev; Oliver Speck Journal: Neuroimage Date: 2012-02-28 Impact factor: 6.556