Literature DB >> 18666126

DWI of the spinal cord with reduced FOV single-shot EPI.

Emine Ulku Saritas1, Charles H Cunningham, Jin Hyung Lee, Eric T Han, Dwight G Nishimura.   

Abstract

Single-shot echo-planar imaging (ss-EPI) has not been used widely for diffusion-weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross-sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long readout duration of the ss-EPI method. Reduced field-of-view (FOV) methods decrease the required readout duration for ss-EPI, thereby enabling its practical application to imaging of the spine. In this work, a reduced FOV single-shot diffusion-weighted echo-planar imaging (ss-DWEPI) method is proposed, in which a 2D spatially selective echo-planar RF excitation pulse and a 180 degrees refocusing pulse reduce the FOV in the phase-encode (PE) direction, while suppressing the signal from fat simultaneously. With this method, multi slice images with higher in-plane resolutions (0.94 x 0.94 mm(2) for sagittal and 0.62 x 0.62 mm(2) for axial images) are achieved at 1.5 T, without the need for a longer readout. (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18666126     DOI: 10.1002/mrm.21640

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  81 in total

1.  Drop metastases to the pediatric spine revealed with diffusion-weighted MR imaging.

Authors:  Laura L Hayes; Richard A Jones; Susan Palasis; Dolly Aguilera; David A Porter
Journal:  Pediatr Radiol       Date:  2011-11-04

2.  Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence.

Authors:  N Barakat; F B Mohamed; L N Hunter; P Shah; S H Faro; A F Samdani; J Finsterbusch; R Betz; J Gaughan; M J Mulcahey
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

3.  Reduced field-of-view excitation using second-order gradients and spatial-spectral radiofrequency pulses.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2012-04-05       Impact factor: 4.668

4.  3T diffusion-weighted MRI of the thyroid gland with reduced distortion: preliminary results.

Authors:  V Taviani; S Nagala; A N Priest; M A McLean; P Jani; M J Graves
Journal:  Br J Radiol       Date:  2013-06-14       Impact factor: 3.039

5.  Comparison of field-of-view optimized and constrained undistorted single-shot diffusion-weighted imaging and conventional diffusion-weighted imaging of optic nerve and chiasma at 3T.

Authors:  Yuan Tian; Junqing Wang; Mingge Li; Xin Lou; Jing Tang; Quangang Xu; Yingkui Zhang; Shihui Wei; Lin Ma
Journal:  Neuroradiology       Date:  2018-07-19       Impact factor: 2.804

6.  Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: Diagnostic value of reduced field of view DWI.

Authors:  Maarten W Barentsz; Valentina Taviani; Jung M Chang; Debra M Ikeda; Kanae K Miyake; Suchandrima Banerjee; Maurice A A J van den Bosch; Brian A Hargreaves; Bruce L Daniel
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

Review 7.  Focal ablation of prostate cancer: four roles for magnetic resonance imaging guidance.

Authors:  Graham Sommer; Donna Bouley; Harcharan Gill; Bruce Daniel; Kim Butts Pauly; Chris Diederich
Journal:  Can J Urol       Date:  2013-04       Impact factor: 1.344

8.  Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T.

Authors:  Samantha By; Alex K Smith; Lindsey M Dethrage; Bailey D Lyttle; Bennett A Landman; Jeffrey L Creasy; Siddharama Pawate; Seth A Smith
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

9.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

10.  Signal scaling improves the signal-to-noise ratio of measurements with segmented 2D-selective radiofrequency excitations.

Authors:  Jürgen Finsterbusch; Martin G Busch; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.