Literature DB >> 3488338

A maximum likelihood method for region-of-interest evaluation in emission tomography.

R E Carson.   

Abstract

A maximum likelihood (ML) estimation method, called the ML-ROI algorithm, is presented for the calculation of region-of-interest (ROI) values from emission tomography scans. The EM algorithm is used to directly estimate ROI values from tomographic projection data given the location, size, and shape of all ROIs. The algorithm requires for the specification of a detailed model of the physical factors contributing to projection measurements including resolution and attenuation. The ML-ROI algorithm also provides an estimate of the variability of the ROI estimator (covariance matrix). The algorithm was tested with simulation and phantom data and compared with ROI estimation strategies using filtered backprojection (FBP) images. The ML-ROI estimates were unbiased, i.e., the partial volume effect was eliminated. Except for regions smaller than the detector resolution, the variability of the ML estimates was comparable to or less than the biased FBP estimators. Computation time for the ML-ROI algorithm was between 5 and 10 s/iteration. An evaluation of the sensitivity of the algorithm to misdefinition of the location and size of the ROIs was also performed.

Mesh:

Year:  1986        PMID: 3488338     DOI: 10.1097/00004728-198607000-00021

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  13 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

3.  Representation of photon limited data in emission tomography using origin ensembles.

Authors:  A Sitek
Journal:  Phys Med Biol       Date:  2008-05-27       Impact factor: 3.609

4.  Evaluation of a method for projection-based tissue-activity estimation within small volumes of interest.

Authors:  Sudeepti Southekal; Sarah J McQuaid; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2012-01-13       Impact factor: 3.609

5.  Improved regional activity quantitation in nuclear medicine using a new approach to correct for tissue partial volume and spillover effects.

Authors:  Stephen C Moore; Sudeepti Southekal; Mi-Ae Park; Sarah J McQuaid; Marie Foley Kijewski; Stefan P Müller
Journal:  IEEE Trans Med Imaging       Date:  2011-09-29       Impact factor: 10.048

6.  Scanning linear estimation: improvements over region of interest (ROI) methods.

Authors:  Meredith K Kupinski; Eric W Clarkson; Harrison H Barrett
Journal:  Phys Med Biol       Date:  2013-02-06       Impact factor: 3.609

7.  Improved quantification for local regions of interest in preclinical PET imaging.

Authors:  J Cal-González; S C Moore; M-A Park; J L Herraiz; J J Vaquero; M Desco; J M Udias
Journal:  Phys Med Biol       Date:  2015-09-03       Impact factor: 3.609

8.  Noninvasive quantification of regional myocardial blood flow and ammonia extraction fraction using nitrogen-13 ammonia and positron emission tomography.

Authors:  M Endo; K Yoshida; T A Iinuma; T Yamasaki; Y Tateno; Y Masuda; Y Inagaki
Journal:  Ann Nucl Med       Date:  1987-09       Impact factor: 2.668

9.  A direct ROI quantification method for inherent PVE correction: accuracy assessment in striatal SPECT measurements.

Authors:  Eleonora Vanzi; Maria Teresa De Cristofaro; Silvia Ramat; Barbara Sotgia; Mario Mascalchi; Andreas Robert Formiconi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-28       Impact factor: 9.236

10.  Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept.

Authors:  Katsuyuki Taguchi; Thomas J Sauer; W Paul Segars; Eric C Frey; Jingyan Xu; Eleni Liapi; J Webster Stayman; Kelvin Hong; Ferdinand K Hui; Mathias Unberath; Yong Du
Journal:  Med Phys       Date:  2020-10-22       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.