Diagnostic Accuracy of Three-Dimensional Endoanal Ultrasound for Anal Fistula: A Systematic Review and Meta-analysis.

Jin Li1, Shao-Na Chen1, Yun-Yong Lin1, Zhi-Min Zhu1, Da-Lin Ye1, Fei Chen1, Shao-Dong Qiu1.   

Abstract

BACKGROUND: Anal fistula is a relatively common anorectal disease. An accurate assessment of the main anal fistula type and the anatomy of the internal opening before surgery is necessary to obtain the best surgical results. Whether three-dimensional endoanal ultrasound (3D-EAUS) should be used as the first-line diagnostic tool for anal fistula is still controversial. The purpose of this study is to conduct a meta-analysis of the published literature on 3D-EAUS and anal fistula, and compare the results of 3D-EAUS and surgery to evaluate the diagnostic value of 3D-EAUS for anal fistula.
METHODS: An online search of databases in English included PubMed, Embase, and Cochrane Library. After the diagnostic accuracy of 3D-EAUS of all anal fistula types was integrated, a single-group rate meta-analysis was performed; we analyzed 3D-EAUS separately for the diagnosis of different anal fistula types, and conducted a meta-analysis of test accuracy. The analysis combined sensitivity, specificity, and the respective 95% CI, to draw a summary receiver operating characteristic curve (SROC), and estimate the area under curve (AUC).
RESULTS: Based on the inclusion criteria, we selected 8 studies covering 1057 cases of anal fistula and 548 cases of internal opening. The meta-analysis data show that 3D-EAUS has a total accuracy rate of 91% (95% CI, 88-94%). It has high sensitivity and specificity for different anal fistula classifications. The SROC curves for anal fistula internal openings were plotted, and the AUC was calculated to be 0.86 (95% CI, 0.83-0.89).
CONCLUSIONS: 3D-EAUS can be used as the first-line diagnostic tool for anal fistula, because it has a high diagnostic accuracy for most anal fistulas. However, due to the insufficient diagnostic accuracy of 3D-EAUS for complex fistulas, 3D-EAUS combined with MRI examination can be used to more accurately detect the secondary extension of complex fistulas, so as to describe the complete anatomy of the fistula in more detail.

Entities:  

Mesh:

Year:  2021        PMID: 34872892      PMCID: PMC8975359          DOI: 10.5152/tjg.2021.20750

Source DB:  PubMed          Journal:  Turk J Gastroenterol        ISSN: 1300-4948            Impact factor:   1.852


  22 in total

1.  Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging of perianal fistulas.

Authors:  R L West; D D E Zimmerman; S Dwarkasing; S M Hussain; W C J Hop; W R Schouten; E J Kuipers; R J F Felt-Bersma
Journal:  Dis Colon Rectum       Date:  2003-10       Impact factor: 4.585

2.  Preoperative assessment of simple and complex anorectal fistulas: Tridimensional endoanal ultrasound? Magnetic resonance? Both?

Authors:  Antonio Brillantino; Francesca Iacobellis; Alfonso Reginelli; Luigi Monaco; Biagio Sodano; Giuseppe Tufano; Antonio Tufano; Mauro Maglio; Maurizio De Palma; Natale Di Martino; Adolfo Renzi; Roberto Grassi
Journal:  Radiol Med       Date:  2019-01-03       Impact factor: 3.469

3.  Anal endosonography in the evaluation of perianal sepsis and fistula in ano.

Authors:  P J Law; R W Talbot; C I Bartram; J M Northover
Journal:  Br J Surg       Date:  1989-07       Impact factor: 6.939

Review 4.  Imaging of fistula in ano.

Authors:  Steve Halligan; Jaap Stoker
Journal:  Radiology       Date:  2006-04       Impact factor: 11.105

5.  [Evaluation of three-dimensional endoanal endosonography of perianal fistulas and correlation with surgical findings].

Authors:  Marina Garcés Albir; Stephanie García Botello; Pedro Esclápez Valero; Angel Sanahuja Santafé; Alejandro Espí Macías; Blas Flor Lorente; Eduardo García-Granero
Journal:  Cir Esp       Date:  2010-04-13       Impact factor: 1.653

6.  The accuracy of a postprocessing technique--volume render mode--in three-dimensional endoanal ultrasonography of anal abscesses and fistulas.

Authors:  Iwona Sudoł-Szopińska; Małgorzata Kołodziejczak; Tomasz R Szopiński
Journal:  Dis Colon Rectum       Date:  2011-02       Impact factor: 4.585

7.  Clinical examination, endosonography, and MR imaging in preoperative assessment of fistula in ano: comparison with outcome-based reference standard.

Authors:  Gordon N Buchanan; Steve Halligan; Clive I Bartram; Andrew B Williams; Danilo Tarroni; C Richard G Cohen
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

8.  Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano.

Authors:  Gordon N Buchanan; Clive I Bartram; Andrew B Williams; Steve Halligan; C Richard G Cohen
Journal:  Dis Colon Rectum       Date:  2005-01       Impact factor: 4.585

Review 9.  Current techniques in imaging of fistula in ano: three-dimensional endoanal ultrasound and magnetic resonance imaging.

Authors:  Maryellen R M Sun; Martin P Smith; Robert A Kane
Journal:  Semin Ultrasound CT MR       Date:  2008-12       Impact factor: 1.875

10.  QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies.

Authors:  Penny F Whiting; Anne W S Rutjes; Marie E Westwood; Susan Mallett; Jonathan J Deeks; Johannes B Reitsma; Mariska M G Leeflang; Jonathan A C Sterne; Patrick M M Bossuyt
Journal:  Ann Intern Med       Date:  2011-10-18       Impact factor: 25.391

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.