Literature DB >> 3486341

Variation of the count-dependent Metz filter with imaging system modulation transfer function.

M A King, R B Schwinger, B C Penney.   

Abstract

A systematic investigation was conducted of how a number of parameters which alter the system modulation transfer function (MTF) influence the count-dependent Metz filter. Since restoration filters are most effective at those frequencies where the object power spectrum dominates that of the noise, it was observed that parameters which significantly degrade the MTF at low spatial frequencies strongly influence the formation of the Metz filter. Thus the radionuclide imaged and the depth of the source in a scattering medium had the most influence. This is because they alter the relative amount of scattered radiation being imaged. For low-energy photon emitters, the collimator employed and the distance from the collimator were found to have less of an influence but still to be significant. These cause alterations in the MTF which are more gradual, and hence are most pronounced at mid to high spatial frequencies. As long as adequate spatial sampling is employed, the Metz filter was determined to be independent of the exact size of the sampling bin width, to a first approximation. For planar and single photon emission computed tomographic (SPECT) imaging, it is shown that two-dimensional filtering with the Metz filter optimized for the imaging conditions is able to deconvolve scatter and other causes of spatial resolution loss while diminishing noise, all in a balanced manner.

Mesh:

Substances:

Year:  1986        PMID: 3486341     DOI: 10.1118/1.595938

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

Review 2.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

3.  Optimum tomographic reconstruction parameters for HMPAO brain SPET imaging: a practical approach based on subjective and objective indexes.

Authors:  P O Kotzki; D Mariano-Goulart; M Quiquere; F Lyonnet; M Zanca; M Rossi
Journal:  Eur J Nucl Med       Date:  1995-07

4.  Expectation maximization in quantitative single-photon emission tomography.

Authors:  A K Blokland
Journal:  Eur J Nucl Med       Date:  1994-07

5.  Adaptive noise reduction of scintigrams with a wavelet transform.

Authors:  Koichi Ogawa; Masahiko Sakata; Yu Li
Journal:  Int J Biomed Imaging       Date:  2012-02-28
  5 in total