Literature DB >> 34858678

Combined anterior segment OCT and wavefront-based autorefractor using a shared beam.

Marco Ruggeri1,2, Giulia Belloni1,3, Yu-Cherng Chang1,2, Heather Durkee1,2, Ettore Masetti1,3, Florence Cabot1,4, Sonia H Yoo1,4, Arthur Ho1,5,6, Jean-Marie Parel1,2,4,5, Fabrice Manns1,2.   

Abstract

We have combined an anterior segment (AS) optical coherence tomography (OCT) system and a wavefront-based aberrometer with an approach that senses ocular wavefront aberrations using the OCT beam. Temporal interlacing of the OCT and aberrometer channels allows for OCT images and refractive error measurements to be acquired continuously and in real-time. The system measures refractive error with accuracy and precision comparable to that of clinical autorefractors. The proposed approach provides a compact modular design that is suitable for integrating OCT and wavefront-based autorefraction within the optical head of the ophthalmic surgical microscope for guiding cataract surgery or table-top devices for simultaneous autorefraction and ocular biometry.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2021        PMID: 34858678      PMCID: PMC8606132          DOI: 10.1364/BOE.435127

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.562


  44 in total

1.  Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K autorefractor.

Authors:  Leon Nicholas Davies; Edward Arthur Harry Mallen; James Stuart Wolffsohn; Bernard Gilmartin
Journal:  Optom Vis Sci       Date:  2003-04       Impact factor: 1.973

2.  Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina.

Authors:  Yan Zhang; Jungtae Rha; Ravi Jonnal; Donald Miller
Journal:  Opt Express       Date:  2005-06-13       Impact factor: 3.894

3.  Measurement of wavefront aberrations and lens deformation in the accommodated eye with optical coherence tomography-equipped wavefront system.

Authors:  Ji C He; Jianhua Wang
Journal:  Opt Express       Date:  2014-04-21       Impact factor: 3.894

4.  Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral-domain optical coherence tomography.

Authors:  Lyubomyr M Lytvynchuk; Carl G Glittenberg; Christiane I Falkner-Radler; Beatrix Neumaier-Ammerer; Eva Smretschnig; Stefan Hagen; Siamak Ansari-Shahrezaei; Susanne Binder
Journal:  J Cataract Refract Surg       Date:  2016-05       Impact factor: 3.351

5.  Validation of an Affordable Handheld Wavefront Autorefractor.

Authors:  Marcos Rubio; Carlos S Hernández; Enrique Seco; Pablo Perez-Merino; Ignacio Casares; Shivang R Dave; Daryl Lim; Nicholas J Durr; Eduardo Lage
Journal:  Optom Vis Sci       Date:  2019-10       Impact factor: 1.973

6.  Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

Authors:  Justis P Ehlers; Jeff Goshe; William J Dupps; Peter K Kaiser; Rishi P Singh; Richard Gans; Jonathan Eisengart; Sunil K Srivastava
Journal:  JAMA Ophthalmol       Date:  2015-10       Impact factor: 7.389

7.  Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results.

Authors:  Michael G Woodcock; Robert Lehmann; Robert J Cionni; Michael Breen; Maria C Scott
Journal:  J Cataract Refract Surg       Date:  2016-06       Impact factor: 3.351

8.  Investigation of the isoplanatic patch and wavefront aberration along the pupillary axis compared to the line of sight in the eye.

Authors:  Maciej Nowakowski; Matthew Sheehan; Daniel Neal; Alexander V Goncharov
Journal:  Biomed Opt Express       Date:  2012-01-03       Impact factor: 3.732

9.  Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch.

Authors:  Marco Ruggeri; Stephen R Uhlhorn; Carolina De Freitas; Arthur Ho; Fabrice Manns; Jean-Marie Parel
Journal:  Biomed Opt Express       Date:  2012-06-06       Impact factor: 3.732

10.  Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT).

Authors:  Philipp Steven; Carolin Le Blanc; Eva Lankenau; Marc Krug; Stefan Oelckers; Ludwig M Heindl; Uta Gehlsen; Gereon Huettmann; Claus Cursiefen
Journal:  Br J Ophthalmol       Date:  2014-07       Impact factor: 4.638

View more
  1 in total

Review 1.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30
  1 in total