Literature DB >> 12692490

Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K autorefractor.

Leon Nicholas Davies1, Edward Arthur Harry Mallen, James Stuart Wolffsohn, Bernard Gilmartin.   

Abstract

PURPOSE: A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry.
METHODS: Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 +/- 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days.
RESULTS: Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 +/- 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 +/- 0.09 mm; vertical: difference, 0.01 +/- 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 +/- 0.09 mm; vertical: intersession difference, -0.01 +/- 0.12 mm).
CONCLUSION: The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.

Entities:  

Mesh:

Year:  2003        PMID: 12692490     DOI: 10.1097/00006324-200304000-00011

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  45 in total

1.  Static and dynamic measurements of accommodation in individuals with down syndrome.

Authors:  Heather A Anderson; Ruth E Manny; Adrian Glasser; Karla K Stuebing
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-01-05       Impact factor: 4.799

2.  Prediction of Juvenile-Onset Myopia.

Authors:  Karla Zadnik; Loraine T Sinnott; Susan A Cotter; Lisa A Jones-Jordan; Robert N Kleinstein; Ruth E Manny; J Daniel Twelker; Donald O Mutti
Journal:  JAMA Ophthalmol       Date:  2015-06       Impact factor: 7.389

3.  Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.

Authors:  Ravi C Bakaraju; Cathleen Fedtke; Klaus Ehrmann; Arthur Ho
Journal:  J Optom       Date:  2015-02-07

4.  Comparison of laser ray-tracing and skiascopic ocular wavefront-sensing devices.

Authors:  D-U G Bartsch; K Bessho; L Gomez; W R Freeman
Journal:  Eye (Lond)       Date:  2007-06-15       Impact factor: 3.775

5.  Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

Authors:  Meritxell Vilaseca; Montserrat Arjona; Jaume Pujol; Elvira Peris; Vanessa Martínez
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

Review 6.  Restoration of accommodation: surgical options for correction of presbyopia.

Authors:  Adrian Glasser
Journal:  Clin Exp Optom       Date:  2008-05       Impact factor: 2.742

7.  Central and peripheral autorefraction repeatability in normal eyes.

Authors:  Kelly E Moore; David A Berntsen
Journal:  Optom Vis Sci       Date:  2014-09       Impact factor: 1.973

8.  Keratometry with five different techniques: a study of device repeatability and inter-device agreement.

Authors:  Shiva Mehravaran; Soheila Asgari; Sara Bigdeli; Ashkan Shahnazi; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2014-02-23       Impact factor: 2.031

9.  Aberrometry Repeatability and Agreement with Autorefraction.

Authors:  Mylan T Nguyen; David A Berntsen
Journal:  Optom Vis Sci       Date:  2017-09       Impact factor: 1.973

10.  Receding and disparity cues aid relaxation of accommodation.

Authors:  Anna M Horwood; Patricia M Riddell
Journal:  Optom Vis Sci       Date:  2009-11       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.