Literature DB >> 34826249

Radiation exposure in 101 non-coronary fluoroscopically guided interventional procedures: reference levels of air kerma at the reference point and air kerma area product.

Xinhua Li1, Joshua Adam Hirsch1, Madan M Rehani1, Kai Yang1, Theodore Alan Marschall1, Bob Liu1.   

Abstract

OBJECTIVES: To present the median value and 75th percentile of air kerma at the reference point (Ka,r), air kerma-area product (KAP), and fluoroscopic time for a large number of fluoroscopically guided interventional (FGI) procedures.
METHODS: This retrospective study included the consecutive non-coronary FGI procedures from a Radiology department between May 2016 and October 2018 at a large tertiary-care hospital in the U.S. An in-house developed, semi-automated software, integrated with a dictation system, was used to record patient examination information, including Ka,r, KAP and fluoroscopic time. The included patient procedures were categorized into procedure types. A software package R (v. 3.5.1, R Foundation) was used to calculate procedure-specific quartiles of radiation exposure.
RESULTS: Based on analysis of 24,911 FGI cases, median value and 75th percentile are presented for each of Ka,r, KAP and fluoroscopic time for 101 procedures that can act as benchmark for comparison for dose optimization studies.
CONCLUSION: This study provides reference levels ( 50th and 75th percentiles) for a comprehensive list of FGI procedures, reflecting an overall picture of the latest FGI studies for diagnosis, targeted minimally invasive intervention, and therapeutic treatment. ADVANCES IN KNOWLEDGE: This study provides reference levels (50th and 75th percentiles) for the largest number of fluoroscopically guided interventional procedures reported to date (101 procedures), in terms of air kerma at the reference point, air kerma-area product, and fluoroscopic time, among which these quartiles for ≥50 procedures are presented for the first time.

Entities:  

Mesh:

Year:  2021        PMID: 34826249      PMCID: PMC8822547          DOI: 10.1259/bjr.20211108

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  14 in total

1.  Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID.

Authors:  Alexander A Schegerer; Guy Frija; Graciano Paulo; Werner Jaschke; Virginia Tsapaki; Jacques Repussard; John Damilakis
Journal:  Eur Radiol       Date:  2021-05-15       Impact factor: 5.315

2.  Establishing Local Diagnostic Reference Levels in IR Procedures with Dose Management Software.

Authors:  Christina Heilmaier; Niklaus Zuber; Christian Berthold; Levent Kara; Dominik Weishaupt
Journal:  J Vasc Interv Radiol       Date:  2016-12-26       Impact factor: 3.464

3.  NATIONAL DIAGNOSTIC REFERENCE LEVELS IN INTERVENTIONAL RADIOLOGY SUITES IN LEBANON: A MULTICENTER SURVEY.

Authors:  C Rizk; J Farah; F Vanhavere; G Fares
Journal:  Radiat Prot Dosimetry       Date:  2019-12-31       Impact factor: 0.972

4.  Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

Authors:  Cécile Etard; Emeline Bigand; Cécile Salvat; Vincent Vidal; Jean Paul Beregi; Amaury Hornbeck; Joël Greffier
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

Review 5.  Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre study.

Authors:  Daniel Schmitz; Thomas Vogl; Nour-Eldin Abdelrehim Nour-Eldin; Boris Radeleff; Jens-Christian Kröger; Andreas H Mahnken; Harald Ittrich; Hans-Björn Gehl; Bernd Plessow; Joachim Böttcher; Josef Tacke; Markus Wispler; Ulrich Rosien; Wolfgang Schorr; Markus Joerdens; Nicolas Glaser; Erik-Sebastian Fuchs; Andrea Tal; Bettina Friesenhahn-Ochs; Thomas Leimbach; Lars Höpner; Marko Weber; Stefan Gölder; Michael Böhmig; Svetlana Hetjens; Jochen Rudi; Alexander Schegerer
Journal:  Eur Radiol       Date:  2019-04-23       Impact factor: 5.315

6.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

7.  Radiation Dose Monitoring for Fluoroscopically Guided Interventional Procedures: Effect on Patient Radiation Exposure.

Authors:  Bob Liu; Joshua A Hirsch; Xinhua Li; Robert M Sheridan; Madan M Rehani; Hui Zheng; James D Rabinov
Journal:  Radiology       Date:  2019-01-15       Impact factor: 11.105

8.  Diagnostic Reference Levels for Diagnostic and Interventional X-Ray Procedures in Germany: Update and Handling.

Authors:  Alexander Schegerer; Reinhard Loose; Lothar J Heuser; Gunnar Brix
Journal:  Rofo       Date:  2019-01-21

Review 9.  Should interventional radiology gain speciality status within the royal college of radiologists?

Authors:  Yakup Kilic; Shahzad Illyas
Journal:  Br J Radiol       Date:  2020-12-11       Impact factor: 3.039

10.  Diagnostic reference levels and median doses for common clinical indications of CT: findings from an international registry.

Authors:  Denise Bos; Sophronia Yu; Jason Luong; Philip Chu; Yifei Wang; Andrew J Einstein; Jay Starkey; Bradley N Delman; Phuong-Anh T Duong; Marco Das; Sebastian Schindera; Allen R Goode; Fiona MacLeod; Axel Wetter; Rebecca Neill; Ryan K Lee; Jodi Roehm; James A Seibert; Luisa F Cervantes; Nima Kasraie; Pavlina Pike; Anokh Pahwa; Cécile R L P N Jeukens; Rebecca Smith-Bindman
Journal:  Eur Radiol       Date:  2021-10-13       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.