Literature DB >> 34806095

Method for analysis of environmental lead contamination in soils.

Chloe A Beardsley1, Kai Z Fuller1, Thomas H Reilly1, Charles S Henry1,2.   

Abstract

A method for lead (Pb) detection in soil is presented. Pb is a dangerous environmental pollutant that is present in soils, posing a health risk to millions of people worldwide, and regular monitoring of Pb contamination in soils is essential to public health. Many sensitive methods for detection of heavy metals in solid matrices exist, but they cannot be performed on-site because they are costly (>$30 per sample), require trained personnel, and many classical sample preparation methods are not safe to bring into the field. We describe an alternative process, combining a safer sample preparation method with electrochemical analysis. The process requires minimal training, making it an attractive overall method for regular environmental screening of Pb in soils. Extract obtained from the soil is pH adjusted and analyzed using a stencil-printed carbon electrode and square wave anodic stripping voltammetry. In this work, a study of 15 neighborhood soils examining the concentration of Pb present post-extraction was performed to demonstrate the method. The limit of detection for the electrochemical analysis was calculated to be 16 ppb-well below the United States Environmental Protection Agency's action limit for Pb in soils (400 mg kg-1 or 4000 ppb)-and third party inductively coupled plasma-optical emission spectroscopy analysis validated the results obtained in this study to within ±17% on average.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34806095      PMCID: PMC9387210          DOI: 10.1039/d1an01744f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   5.227


  25 in total

1.  Bismuth-coated carbon electrodes for anodic stripping voltammetry

Authors: 
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

2.  Kinetic limitations in measuring stabilities of metal complexes by competitive ligand exchange-adsorptive stripping voltammetry (CLE-AdSV).

Authors:  Herman P Van Leeuwen; Raewyn M Town
Journal:  Environ Sci Technol       Date:  2005-09-15       Impact factor: 9.028

3.  Sputtered bismuth screen-printed electrode: a promising alternative to other bismuth modifications in the voltammetric determination of Cd(II) and Pb(II) ions in groundwater.

Authors:  Velia Sosa; Núria Serrano; Cristina Ariño; José Manuel Díaz-Cruz; Miquel Esteban
Journal:  Talanta       Date:  2013-11-14       Impact factor: 6.057

Review 4.  Functionality of surfactants in waste-activated sludge treatment: A review.

Authors:  Renpeng Guan; Xingzhong Yuan; Zhibin Wu; Hou Wang; Longbo Jiang; Yifu Li; Guangming Zeng
Journal:  Sci Total Environ       Date:  2017-08-07       Impact factor: 7.963

5.  Alteration of the Copper-Binding Capacity of Iron-Rich Humic Colloids during Transport from Peatland to Marine Waters.

Authors:  François L L Muller; Marco Cuscov
Journal:  Environ Sci Technol       Date:  2017-02-28       Impact factor: 9.028

6.  Carbon nanotube-loaded Nafion film electrochemical sensor for metal ions: europium.

Authors:  Tingting Wang; Daoli Zhao; Xuefei Guo; Jaime Correa; Bill L Riehl; William R Heineman
Journal:  Anal Chem       Date:  2014-04-18       Impact factor: 6.986

7.  Lead in drinking water at North Carolina childcare centers: Piloting a citizen science-based testing strategy.

Authors:  Jennifer Hoponick Redmon; Keith E Levine; Anna M Aceituno; Kristin Litzenberger; Jacqueline MacDonald Gibson
Journal:  Environ Res       Date:  2020-01-11       Impact factor: 6.498

8.  Metals analysis of botanical products in various matrices using a single microwave digestion and inductively coupled plasma optical emission spectrometry (ICP-OES) method.

Authors:  Joaudimir Castro; Julia C Spraul; R Kenneth Marcus
Journal:  Anal Methods       Date:  2009-12-01       Impact factor: 2.896

Review 9.  Lead toxicity: a review.

Authors:  Ab Latif Wani; Anjum Ara; Jawed Ahmad Usmani
Journal:  Interdiscip Toxicol       Date:  2015-06

10.  Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead.

Authors:  Alyssa A Kava; Chloe Beardsley; Josephine Hofstetter; Charles S Henry
Journal:  Anal Chim Acta       Date:  2019-12-31       Impact factor: 6.558

View more
  1 in total

1.  Detection Efficiency of Ag Nanoparticle Labels for a Heart Failure Marker Using Linear and Square-Wave Anodic Stripping Voltammetry.

Authors:  Nikhil Raj; Richard M Crooks
Journal:  Biosensors (Basel)       Date:  2022-03-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.