Literature DB >> 32081189

Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead.

Alyssa A Kava1, Chloe Beardsley2, Josephine Hofstetter3, Charles S Henry4.   

Abstract

Cadmium (Cd) and lead (Pb) pollution is a significant environmental and human health concern, and methods to detect Cd and Pb on site are valuable. Stencil-printed carbon electrodes (SPCEs) are an attractive electrode material for point-of-care (POC) applications due to their low cost, ease of fabrication, disposability and portability. At present, SPCEs are exclusively formulated from graphitic carbon powder and conductive carbon ink. However, graphitic carbon SPCEs are not ideal for heavy metal sensing due to the heterogeneity of graphitic SPCE surfaces. Moreover, SPCEs typically require extensive modification to provide desirable detection limits and sensitivity at the POC, significantly increasing cost and complexity of analysis. While there are many examples of chemically modified SPCEs, the bulk SPCE composition has not been studied for heavy metal detection. Here, a glassy carbon microparticle stencil printed electrode (GC-SPE) was developed. The GC-SPEs were first characterized with SEM and cyclic voltammetry and then optimized for Cd and Pb detection with an in situ Bi-film plated. The GC-SPEs require no chemical modification or pretreatment significantly decreasing the cost and complexity of fabrication. The detection limits for Cd and Pb were estimated to be 0.46 μg L-1 and 0.55 μg L-1, respectively, which are below EPA limits for drinking water (5 μg L-1 Cd and 10 μg L-1 Pb) [1]. The reported GC-SPEs are advantageous with their low cost, ease of fabrication and use, and attractive performance. The GC-SPEs can be used for low-level metal detection at the POC as shown in the report herein.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anodic stripping voltammetry; Glassy carbon; Stencil-printed carbon electrodes

Year:  2019        PMID: 32081189      PMCID: PMC7036080          DOI: 10.1016/j.aca.2019.12.047

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  34 in total

1.  Diagnostics for the developing world: microfluidic paper-based analytical devices.

Authors:  Andres W Martinez; Scott T Phillips; George M Whitesides; Emanuel Carrilho
Journal:  Anal Chem       Date:  2010-01-01       Impact factor: 6.986

2.  A practical guide to using boron doped diamond in electrochemical research.

Authors:  Julie V Macpherson
Journal:  Phys Chem Chem Phys       Date:  2014-12-18       Impact factor: 3.676

3.  Recent Developments in Carbon Sensors for At-Source Electroanalysis.

Authors:  Melinda Hersey; Shane N Berger; Jordan Holmes; Alyssa West; Parastoo Hashemi
Journal:  Anal Chem       Date:  2018-12-17       Impact factor: 6.986

4.  Electrochemistry in hollow-channel paper analytical devices.

Authors:  Christophe Renault; Morgan J Anderson; Richard M Crooks
Journal:  J Am Chem Soc       Date:  2014-03-17       Impact factor: 15.419

Review 5.  Magnetic separation techniques in sample preparation for biological analysis: a review.

Authors:  Jincan He; Meiying Huang; Dongmei Wang; Zhuomin Zhang; Gongke Li
Journal:  J Pharm Biomed Anal       Date:  2014-04-24       Impact factor: 3.935

6.  Point-of-need simultaneous electrochemical detection of lead and cadmium using low-cost stencil-printed transparency electrodes.

Authors:  Daniel Martín-Yerga; Isabel Álvarez-Martos; M Carmen Blanco-López; Charles S Henry; M Teresa Fernández-Abedul
Journal:  Anal Chim Acta       Date:  2017-06-13       Impact factor: 6.558

7.  Inappropriate use of the quasi-reversible electrode kinetic model in simulation-experiment comparisons of voltammetric processes that approach the reversible limit.

Authors:  Alexandr N Simonov; Graham P Morris; Elena A Mashkina; Blair Bethwaite; Kathryn Gillow; Ruth E Baker; David J Gavaghan; Alan M Bond
Journal:  Anal Chem       Date:  2014-07-31       Impact factor: 6.986

8.  Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair. Reference values.

Authors:  Jean-Pierre Goullé; Loïc Mahieu; Julien Castermant; Nicolas Neveu; Laurent Bonneau; Gilbert Lainé; Daniel Bouige; Christian Lacroix
Journal:  Forensic Sci Int       Date:  2005-10-04       Impact factor: 2.395

9.  Manipulation and measurement of pH sensitive metal-ligand binding using electrochemical proton generation and metal detection.

Authors:  Tania L Read; Maxim B Joseph; Julie V Macpherson
Journal:  Chem Commun (Camb)       Date:  2016-01-31       Impact factor: 6.222

10.  Oxidative stress in lead and cadmium toxicity and its amelioration.

Authors:  R C Patra; Amiya K Rautray; D Swarup
Journal:  Vet Med Int       Date:  2011-03-20
View more
  4 in total

1.  Method for analysis of environmental lead contamination in soils.

Authors:  Chloe A Beardsley; Kai Z Fuller; Thomas H Reilly; Charles S Henry
Journal:  Analyst       Date:  2021-12-06       Impact factor: 5.227

2.  Exploring carbon particle type and plasma treatment to improve electrochemical properties of stencil-printed carbon electrodes.

Authors:  Alyssa A Kava; Charles S Henry
Journal:  Talanta       Date:  2020-09-01       Impact factor: 6.057

3.  Electrochemical Immunoassay for the Detection of SARS-CoV-2 Nucleocapsid Protein in Nasopharyngeal Samples.

Authors:  Isabelle C Samper; Catherine J McMahon; Melissa S Schenkel; Kaylee M Clark; Wisarut Khamcharoen; Loran B R Anderson; James S Terry; Emily N Gallichotte; Gregory D Ebel; Brian J Geiss; David S Dandy; Charles S Henry
Journal:  Anal Chem       Date:  2022-03-09       Impact factor: 6.986

4.  Ultrasensitive detection of cadmium ions using a microcantilever-based piezoresistive sensor for groundwater.

Authors:  Dinesh Rotake; Anand Darji; Nitin Kale
Journal:  Beilstein J Nanotechnol       Date:  2020-08-18       Impact factor: 3.649

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.