Study on the established customized limits for the daily quality assurance procedure.

Xiao-Li Jin, Jian-Bo Song, Jin-Xin Peng, Xiao-Peng Pan, Rui Guo, Xiao-Fen Xing.   

Abstract

Since there are no corresponding specification limits for some new daily quality assurance (QA) items in the TG-142, it is a compromise that the specification limits used in the monthly or annual QA procedures are used for the daily QA procedure in work. But there is no basis for whether this is feasible. The purpose of this article is to analyze QA results using SPC to determine the tolerance limits at our institution, and to present the usefulness of the analysis method using SPC. The data of three groups daily QA processes performed with Daily QA3 in three years were analyzed using statistical process control (SPC). For calculating capability indices (Cp, Cpk, Cpm and Cpmk) of processes, the appropriate number of calculation points was analyzed firstly. Then, in calculating the capability indices for output, limits ±3% of the daily QA in the TG-142 were used as the specification limit, while for flatness and symmetry, an annual QA limits of ±1% was used. For putting forward measures to solve the problem, customized tolerance and action limits were established for each process. And the process control charts calculated using data measured by the five therapists and a medical physicist were compared. At least six to eight weeks of control daily check data points (i.e. 30-40 points) should be used for calculating the individuals and moving range (I-MR) control chart to ensure the stability of control lines. Process capability indices of output were all ≥1, some were up to 3-4. While for symmetry, some processes failed to meet the requirements that capability indices were < 1. For different processes of the same daily QA items, the calculated customized limits were quite different. The range of upper control line (UCL) and lower control line (LCL) was smaller for output and the CL was closer to the target value of 0 for flatness and symmetry in the I-MR control chart calculated using data measured by one staff. For different quality control processes without management by the SPC method at our institution, calculated tolerance and action limits of the same measurement item were quite different. And in most measurement items, the specification limits used in the monthly or annual QA procedures in the TG-142 are not suitable to the daily QA procedure. So the analysis method using SPC is useful and necessary.
© The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.

Entities:  

Keywords:  daily QA procedure; daily QA3; statistical process control (SPC)

Mesh:

Year:  2022        PMID: 34734293      PMCID: PMC8776697          DOI: 10.1093/jrr/rrab079

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  16 in total

1.  The systematic application of quality measures and process control in clinical radiation oncology.

Authors:  Todd Pawlicki; Bhisham Chera; Trent Ning; Lawrence B Marks
Journal:  Semin Radiat Oncol       Date:  2012-01       Impact factor: 5.934

2.  Statistical process control for radiotherapy quality assurance.

Authors:  Todd Pawlicki; Matthew Whitaker; Arthur L Boyer
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

Review 3.  Control charts, Cusum techniques and funnel plots. A review of methods for monitoring performance in healthcare.

Authors:  Luc Noyez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-06-09

4.  A method of setting limits for the purpose of quality assurance.

Authors:  Taweap Sanghangthum; Sivalee Suriyapee; Gwe-Ya Kim; Todd Pawlicki
Journal:  Phys Med Biol       Date:  2013-09-17       Impact factor: 3.609

5.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

6.  Feasibility study of using statistical process control to customized quality assurance in proton therapy.

Authors:  Jeong-Eun Rah; Dongho Shin; Do Hoon Oh; Tae Hyun Kim; Gwe-Ya Kim
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

7.  Monitoring Daily QA 3 constancy for routine quality assurance on linear accelerators.

Authors:  Diana Binny; Craig M Lancaster; Tanya Kairn; Jamie V Trapp; Scott B Crowe
Journal:  Phys Med       Date:  2016-11-10       Impact factor: 2.685

8.  A multi-institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control.

Authors:  Diana Binny; Trent Aland; Ben R Archibald-Heeren; Jamie V Trapp; Tanya Kairn; Scott B Crowe
Journal:  J Appl Clin Med Phys       Date:  2019-02-20       Impact factor: 2.102

9.  Statistical process control analysis for patient-specific IMRT and VMAT QA.

Authors:  Taweap Sanghangthum; Sivalee Suriyapee; Somyot Srisatit; Todd Pawlicki
Journal:  J Radiat Res       Date:  2012-12-07       Impact factor: 2.724

10.  Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance.

Authors:  Yuting Li; Tucker Netherton; Paige L Nitsch; Song Gao; Ann H Klopp; Peter A Balter; Laurence E Court
Journal:  J Appl Clin Med Phys       Date:  2018-07-17       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.