Acetabular cup stiffness and implant orientation change acetabular loading patterns.

Scott R Small1, Michael E Berend, Leah A Howard, Didem Tunç, Christine A Buckley, Merrill A Ritter.   

Abstract

Acetabular cup orientation has been shown to influence dislocation, impingement, edge loading, contact stress, and polyethylene wear in total hip arthroplasty. Acetabular implant stiffness has been suggested as a factor in pelvic stress shielding and osseous integration. This study was designed to examine the combined effects of acetabular cup orientation and stiffness and on pelvic osseous loading. Four implant designs of varying stiffness were implanted into a composite hemipelvis in 35° or 50° of abduction. Specimens were dynamically loaded to simulate gait and pelvic strains were quantified with a grid of rosette strain gages and digital image correlation techniques. Changes in the joint reaction force orientation significantly altered mean acetabular bone strain values up to 67%. Increased cup abduction resulted in a 12% increase along the medial acetabular wall and an 18% decrease in strain in inferior lateral regions. Imbalanced loading distributions were observed with the stiffer components, resulting in higher, more variable, and localized surface strains. This study illustrates the effects of cup stiffness, gait, and implant orientation on loading distributions across the implanted pelvis.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22854350     DOI: 10.1016/j.arth.2012.05.026

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

Review 1.  The Use of Intraoperative Digital Radiography Alignment Software to Assess Implant Placement in Total Hip Arthroplasty.

Authors:  Jacob P Siebenmorgen; Benjamin M Stronach; Simon C Mears; Jeffrey B Stambough
Journal:  Curr Rev Musculoskelet Med       Date:  2021-10-25

2.  Reverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant.

Authors:  Elise J Martin; Thomas R Duquin; Mark T Ehrensberger
Journal:  J Shoulder Elb Arthroplast       Date:  2021-06-13

3.  Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis.

Authors:  Amanda D Klaassen; Elisabeth A Schäffer; Nienke W Willigenburg; Loes W A H Van Beers; Vanessa A B Scholtes; Victor P M Van der Hulst; Lennard A Koster; Bart L Kaptein; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2022-04-28       Impact factor: 3.925

4.  Impaction technique influences implant stability in low-density bone model.

Authors:  Ruben Doyle; Richard J van Arkel; Sarah Muirhead-Allwood; Jonathan R T Jeffers
Journal:  Bone Joint Res       Date:  2020-07-31       Impact factor: 5.853

5.  Effect of impaction energy on dynamic bone strains, fixation strength, and seating of cementless acetabular cups.

Authors:  Ruben Doyle; Richard J van Arkel; Jonathan R T Jeffers
Journal:  J Orthop Res       Date:  2019-08-02       Impact factor: 3.494