Literature DB >> 30658003

A Prospective, Randomized Study of Surgical Positioning Software Shows Improved Cup Placement in Total Hip Arthroplasty.

William G Hamilton, Nancy L Parks, James F McDonald, Kiel J Pfefferle.   

Abstract

Several technologies are available to assist surgeons with acetabular component positioning in total hip arthroplasty. The purpose of this study was to determine whether surgical positioning software would improve cup position compared with fluoroscopy. This prospective, randomized study compared 200 primary total hip arthroplasty cups placed with and without surgical positioning software. All cases were performed by a single surgeon using the direct anterior approach with fluoroscopy. The target abduction and anteversion angles were set at 40° and 20°, respectively, and measured postoperatively. Cup placement time, total fluoroscopy time, and cup position were compared between groups. Mean abduction was 40.4° (range, 32.7°-49.0°) in the software group compared with 42.3° (range, 33.7°-51.1°) in the control group. The cups placed using software were significantly closer to the target abduction angle (P<.001) with fewer outliers. Mean anteversion was 20.8° (range, 11.2°-31.7°) in the software group compared with 21.8° (range, 11.3°-34.3°) in the control group (P=.063). Eighty-seven percent of cups in the software group fell within 5° of the abduction target, compared with only 68% in the control group (P<.01). Cup placement took longer in the software group (7:04 minutes vs 4:58 minutes, P<.001), and 2 seconds more total fluoroscopy time was used in that group as well (12.9 seconds vs 11.1 seconds, P<.001). The software improved both the accuracy and the precision of cup placement, with only modest increases in surgical time and fluoroscopy time. [Orthopedics. 2019; 42(1):42-47.]. Copyright 2019, SLACK Incorporated.

Entities:  

Mesh:

Year:  2019        PMID: 30658003     DOI: 10.3928/01477447-20190103-02

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

Review 1.  The Use of Intraoperative Digital Radiography Alignment Software to Assess Implant Placement in Total Hip Arthroplasty.

Authors:  Jacob P Siebenmorgen; Benjamin M Stronach; Simon C Mears; Jeffrey B Stambough
Journal:  Curr Rev Musculoskelet Med       Date:  2021-10-25

2.  The Effect of Intraoperative Radiographs on Component Position and Leg Length during Routine Posterior Approach Total Hip Arthroplasty.

Authors:  Nicholas M Brown; James F McDonald; Robert A Sershon; Robert H Hopper
Journal:  Hip Pelvis       Date:  2021-09-06

3.  Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA.

Authors:  Atul F Kamath; Sridhar M Durbhakula; Trevor Pickering; Nathan L Cafferky; Trevor G Murray; Michael A Wind; Stéphane Méthot
Journal:  J Robot Surg       Date:  2021-10-28

Review 4.  Overview of Randomized Controlled Trials in Primary Total Hip Arthroplasty (34,020 Patients): What Have We Learnt?

Authors:  Hosam E Matar; Simon R Platt; Tim N Board; Martyn L Porter
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.