Peter M Maloca1,2,3, Christine Seeger4, Helen Booler4, Philippe Valmaggia5, Ken Kawamoto6, Qayim Kaba6, Nadja Inglin5, Konstantinos Balaskas7, Catherine Egan6, Adnan Tufail6, Hendrik P N Scholl8,5, Pascal W Hasler8, Nora Denk8,5,4. 1. Department of Ophthalmology, University of Basel, 4031, Basel, Switzerland. peter.maloca@iob.ch. 2. Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland. peter.maloca@iob.ch. 3. Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK. peter.maloca@iob.ch. 4. Preclinical Research and Early Development, Pharmaceutical Sciences, Hoffmann-La Roche, 4070, Basel, Switzerland. 5. Institute of Molecular and Clinical Ophthalmology Basel (IOB), 4031, Basel, Switzerland. 6. Moorfields Eye Hospital NHS Foundation Trust, London, EC1V 2PD, UK. 7. Moorfields Ophthalmic Reading Centre, London, UK. 8. Department of Ophthalmology, University of Basel, 4031, Basel, Switzerland.
Abstract
The fovea is a depression in the center of the macula and is the site of the highest visual acuity. Optical coherence tomography (OCT) has contributed considerably in elucidating the pathologic changes in the fovea and is now being considered as an accompanying imaging method in drug development, such as antivascular endothelial growth factor and its safety profiling. Because animal numbers are limited in preclinical studies and automatized image evaluation tools have not yet been routinely employed, essential reference data describing the morphologic variations in macular thickness in laboratory cynomolgus monkeys are sparse to nonexistent. A hybrid machine learning algorithm was applied for automated OCT image processing and measurements of central retina thickness and surface area values. Morphological variations and the effects of sex and geographical origin were determined. Based on our findings, the fovea parameters are specific to the geographic origin. Despite morphological similarities among cynomolgus monkeys, considerable variations in the foveolar contour, even within the same species but from different geographic origins, were found. The results of the reference database show that not only the entire retinal thickness, but also the macular subfields, should be considered when designing preclinical studies and in the interpretation of foveal data.
The fovea is a depression in the center of the macula and is the site of the highest visual acuity. Optical coherence tomography (OCT) has contributed considerably in elucidating the pathologic changes in the fovea and is now being considered as an accompanying imaging method in drug development, such as antivascular endothelial growth factor and its safety profiling. Because animal numbers are limited in preclinical studies and automatized image evaluation tools have not yet been routinely employed, essential reference data describing the morphologic variations in macular thickness in laboratory cynomolgus monkeys are sparse to nonexistent. A hybrid machine learning algorithm was applied for automated OCT image processing and measurements of central retina thickness and surface area values. Morphological variations and the effects of sex and geographical origin were determined. Based on our findings, the fovea parameters are specific to the geographic origin. Despite morphological similarities among cynomolgus monkeys, considerable variations in the foveolar contour, even within the same species but from different geographic origins, were found. The results of the reference database show that not only the entire retinal thickness, but also the macular subfields, should be considered when designing preclinical studies and in the interpretation of foveal data.
The importance of nonhuman primates as models for a multitude of human diseases has been well documented[1-3]. Particularly, research in cynomolgus macaques (Macaca fascicularis) has provided essential insights for the development, nonclinical ocular safety profiling, and therapeutic interventions of drugs, especially for agents or gene therapy administered in the fovea[4-9]. The fovea represents a depression in the middle of the macula and is the site of the highest cone concentration, which is designated as the central bouquet of cones[10].The entire macular thickness represents an important biomarker in assessing a large number of retinal pathologies in humans and nonhuman primates[11,12]. For example, changes in macular thickness were examined in cynomolgus monkeys for the safety assessment of retinal therapies, such as antivascular endothelial growth factor (anti-VEGF) administration[13-15]. These studies have paved the way for a clinical application in humans and established the use of anti-VEGF therapy as a reliable treatment of neovascular age-related macular degeneration[16,17], representing, to date, one of the most frequent and successful ocular interventions[18]. In this context, the use of optical coherence tomography (OCT) as a noninvasive, longitudinally repeatable imaging method of retinal structures with micrometer resolution has considerably contributed to effective and comprehensive monitoring of the response to anti-VEGF treatment and managing treatment interval[19].However, determining a compound’s adverse effects still mostly relies on the histopathologic readout[20]. An important limitation is that such a histopathological examination can only be conducted once, so the longitudinal processes cannot be observed. Furthermore—and for obvious reasons—histology sampling cannot be performed on living humans without invasive and destructive procedures.Although OCT does not allow for the assessment of all morphological parameters, such as the involved cell types or structural changes at the cellular/subcellular level, this technique has advanced the understanding of specific changes at the vitreoretinal interface and fluid changes in the retina. Furthermore, OCT enables the measurement of thickness variations in vivo and the longitudinal monitoring of findings[21,22]. Therefore, OCT imaging in preclinical studies is of unique translational importance to facilitate safety monitoring in clinical trials.To date, there have been two major weaknesses in accompanying OCT imaging: on the one hand, only OCT data of a few cynomolgus monkeys are available[23,24], and these data were mostly analyzed manually[25]. To overcome these limitations and further automate in vivo imaging readout capabilities—thus increasing both the sensitivity and objectivity of preclinical ocular safety assessments—in the current study a machine learning algorithm was developed for retina segmentation in cynomolgus monkeys.Although the term fovea is widely utilized in the clinical context, another goal of the present study was to propose more objective criteria for defining the deepest site of the fovea on OCT images. Thus, a grader-independent and, therefore, objective method to determine the deepest point on OCT images within the fovea (referred to as the nulla) is proposed.A huge reference database of macular OCT images from healthy cynomolgus monkeys was made available, and measures in animals of different geographical origins were compared.Evidence has been found that the entire macular thickness may not be a suitable biomarker in every case because there may be considerable variations in retinal thickness, even within the same species.
Results
Summary statistics and visualizations
Retina thicknesses for the left and right eyes are shown as boxplots in Fig. 1. The boxplots roughly indicate the contour of the foveolar depression, with the smallest thicknesses at the nulla (T5). At the center (T4–T6), a difference between Asian and Mauritian macaques is apparent, with Asian macaques having larger retina thicknesses. Interestingly, at the edges (T1–T3, T7–T9), geographic origin does not seem to play a role, but females tend to have smaller retina thicknesses than males. The data at umbo strongly resemble data at T5. For the retina areas, the patterns are largely the same (Fig. 2). Tables 1, 2, and 3 present detailed summary statistics of all the coefficients. Summary statistics and boxplots are shown for the left and right eyes separately to avoid correlations between the eyes.
Figure 1
Boxplots showing the retina thickness values of the right (a) and left (b) eyes. For each thickness coefficient, numerical data of Mauritius male, Mauritius female, Asian male, and Asian female are plotted. Rectangular boxes represent interquartile ranges (IQR), which extend from Q1 to Q3. A black line in the middle of an IQR indicates a median. Upper whiskers extend to the last datum, which is smaller than Q3 + 1.5 × IQR. Lower whiskers extend to the first datum, which is greater than Q1 − 1.5 × IQR. Data beyond whiskers are outliers and plotted as black circles.
Figure 2
Boxplots of retina areas of the right (a) and left (b) eyes. For each area coefficient, numerical data of Mauritius male, Mauritius female, Asian male, and Asian female are plotted.
Table 1
Summary statistics of retina thickness values with respect to eye side, sex, and origin.
Stats
Sex
Origin
T1
T2
T3
T4
TUn
T5
TUt
T6
T7
T8
T9
OD
Mean
Male
Mauritius
347.2
357.5
354.6
288.1
192.5
192.8
192.9
276.8
330.0
323.4
296.6
Mean
Male
Asian
348.8
356.6
357.2
303.2
212.2
210.0
210.8
295.9
337.1
323.8
298.5
Mean
Female
Mauritius
342.9
352.7
351.1
286.4
193.5
192.8
193.6
279.0
325.5
315.0
290.8
Mean
Female
Asian
340.3
348.4
346.2
288.8
202.7
201.8
202.7
286.7
327.0
317.1
290.7
Min
Male
Mauritius
315.9
331.5
323.7
226.2
179.4
179.4
175.5
234.0
308.1
300.3
273.0
Min
Male
Asian
312.0
327.6
308.1
245.7
187.2
187.2
187.2
253.5
300.3
292.5
273.0
Min
Female
Mauritius
315.9
323.7
323.7
249.6
179.4
179.4
175.5
234.0
304.2
284.7
257.4
Min
Female
Asian
315.9
323.7
315.9
257.4
171.6
175.5
171.6
253.5
300.3
292.5
269.1
Max
Male
Mauritius
374.4
390.0
386.1
323.7
206.7
210.6
210.6
312.0
354.9
351.0
315.9
Max
Male
Asian
378.3
386.1
405.6
366.6
265.2
253.5
276.9
335.4
366.6
362.7
335.4
Max
Female
Mauritius
370.5
382.2
374.4
323.7
210.6
210.6
210.6
312.0
354.9
339.3
312.0
Max
Female
Asian
370.5
374.4
366.6
323.7
245.7
241.8
241.8
323.7
351.0
343.2
312.0
Std
Male
Mauritius
13.2
13.0
13.5
20.5
7.6
7.1
8.4
16.9
11.7
10.5
9.8
Std
Male
Asian
16.4
14.5
16.7
22.5
16.4
15.2
15.8
18.8
13.9
15.1
14.8
Std
Female
Mauritius
14.1
12.2
10.5
19.5
8.0
7.7
8.0
15.4
10.8
11.5
11.3
Std
Female
Asian
13.5
12.5
13.8
18.4
16.1
15.2
16.0
17.3
12.2
10.0
9.7
OS
Mean
Male
Mauritius
347.8
358.4
356.5
292.8
193.7
192.8
193.9
276.6
329.8
323.5
295.4
Mean
Male
Asian
350.4
359.1
359.0
307.6
212.1
207.7
208.1
296.1
338.7
325.7
299.7
Mean
Female
Mauritius
342.6
352.1
352.6
296.9
194.3
192.7
193.2
277.3
325.4
315.7
288.3
Mean
Female
Asian
340.4
348.7
348.6
294.8
203.2
200.6
200.2
282.0
326.5
315.5
288.8
Min
Male
Mauritius
319.8
327.6
327.6
241.8
179.4
175.5
179.4
230.1
304.2
300.3
269.1
Min
Male
Asian
319.8
323.7
304.2
253.5
183.3
183.3
183.3
257.4
304.2
304.2
280.8
Min
Female
Mauritius
312.0
327.6
327.6
249.6
175.5
179.4
179.4
234.0
300.3
284.7
253.5
Min
Female
Asian
319.8
323.7
315.9
253.5
175.5
167.7
167.7
245.7
296.4
292.5
273.0
Max
Male
Mauritius
386.1
390.0
386.1
327.6
214.5
214.5
214.5
308.1
358.8
351.0
319.8
Max
Male
Asian
382.2
393.9
401.7
374.4
273.0
265.2
265.2
331.5
370.5
358.8
327.6
Max
Female
Mauritius
370.5
374.4
374.4
335.4
206.7
206.7
210.6
308.1
354.9
347.1
312.0
Max
Female
Asian
382.2
382.2
374.4
331.5
241.8
241.8
245.7
319.8
347.1
339.3
304.2
Std
Male
Mauritius
13.0
12.8
13.3
19.1
7.3
7.2
8.3
16.5
12.8
10.4
10.5
Std
Male
Asian
15.7
16.3
17.8
24.1
18.2
15.6
16.0
18.8
14.9
14.0
12.8
Std
Female
Mauritius
14.3
11.1
11.6
19.0
7.4
7.1
8.2
16.0
11.6
12.1
11.5
Std
Female
Asian
13.6
12.6
14.3
17.9
15.1
15.7
15.9
16.0
11.7
10.1
8.4
Values are presented in µm.
OD oculus dexter, OS oculus sinister, Std statistical analysis, U umbo, n nasal, t temporal.
Table 2
Summary statistics of retina areas with respect to eye side, sex, and origin.
Stats
Sex
Origin
A1
A2
A3
A4
AUn
AUt
A5
A6
A7
A8
OD
Mean
Male
Mauritius
173,388
178,351
162,236
110,407
18,836
18,786
109,552
152,737
164,084
152,379
Mean
Male
Asian
173,998
178,024
166,776
120,136
20,732
20,675
119,222
159,323
164,887
153,467
Mean
Female
Mauritius
170,944
176,225
161,037
110,488
18,746
18,717
110,469
151,820
160,663
148,861
Mean
Female
Asian
169,848
173,579
159,915
114,358
19,881
19,874
115,285
153,931
161,011
149,622
Min
Male
Mauritius
157,796
167,913
142,089
94,408
16,858
16,858
94,026
136,334
153,925
140,003
Min
Male
Asian
159,409
156,826
139,863
99,916
17,847
17,714
103,829
140,755
149,613
139,719
Min
Female
Mauritius
158,091
161,072
145,803
96,404
17,133
16,961
92,123
139,726
146,988
132,579
Min
Female
Asian
158,158
158,995
144,027
96,402
16,933
17,307
98,310
140,008
148,236
137,386
Max
Male
Mauritius
189,582
194,555
178,505
125,060
20,919
20,889
124,778
168,413
176,493
165,275
Max
Male
Asian
188,342
199,738
191,925
154,682
24,808
25,394
148,440
173,061
180,890
171,661
Max
Female
Mauritius
184,587
191,286
172,045
125,496
20,229
20,192
122,035
165,992
173,616
160,087
Max
Female
Asian
183,525
186,157
171,658
135,746
23,504
23,408
137,657
166,361
173,639
162,680
Std
Male
Mauritius
6517
6584
7937
7071
936
921
6518
6588
5497
4855
Std
Male
Asian
7473
7897
8862
10,254
1588
1506
9099
7199
6924
7579
Std
Female
Mauritius
6353
5773
6326
7323
788
827
6349
5534
5442
5830
Std
Female
Asian
6617
6278
7734
8582
1652
1633
8644
6877
4967
4952
OS
Mean
Male
Mauritius
173,852
178,694
164,033
111,689
18,935
18,881
109,246
152,827
164,143
152,132
Mean
Male
Asian
174,620
179,050
168,332
121,453
20,640
20,494
117,960
160,010
165,783
153,456
Mean
Female
Mauritius
170,989
176,601
163,530
113,695
19,036
18,928
109,380
151,333
160,857
148,438
Mean
Female
Asian
169,996
173,783
161,583
116,636
19,862
19,705
112,829
153,015
160,675
148,970
Min
Male
Mauritius
158,594
165,849
147,303
97,092
16,858
16,895
93,134
137,082
152,414
141,270
Min
Male
Asian
159,752
156,594
143,334
104,732
17,950
17,911
103,378
142,745
150,388
142,451
Min
Female
Mauritius
156,251
163,843
148,892
94,568
16,902
16,844
92,213
136,807
146,109
132,522
Min
Female
Asian
156,710
159,658
144,272
101,938
17,387
16,906
98,550
136,025
149,916
137,714
Max
Male
Mauritius
190,039
192,769
180,932
129,639
21,332
21,284
124,607
169,060
178,684
164,069
Max
Male
Asian
191,610
197,312
195,304
152,599
26,303
25,763
141,757
175,729
181,264
169,739
Max
Female
Mauritius
185,208
187,214
177,139
125,504
21,092
20,741
120,651
165,333
175,781
163,017
Max
Female
Asian
186,704
189,637
174,242
138,178
23,695
23,620
131,750
166,401
170,465
159,715
Std
Male
Mauritius
6456
6247
7487
6535
948
990
6142
6747
5795
5158
Std
Male
Asian
8084
8277
10,029
10,467
1663
1621
8580
8166
6870
6755
Std
Female
Mauritius
6414
5177
7107
6764
923
898
6241
6466
5481
6091
Std
Female
Asian
6759
6404
7669
8105
1537
1581
8072
6688
5217
4482
Values are presented in µm2.
OD oculus dexter, OS oculus sinister, Std statistical analysis, U umbo, n nasal, t temporal.
Table 3
Summary subfield analysis of umbo retina thickness and area values.
OD
OS
TUt
Nulla
TUn
TUt
Nulla
TUn
A. Males
Mean
202
201
202
201
200
202
Min
176
179
179
179
176
179
Max
277
254
265
265
265
273
Std
16
15
16
15
14
16
Values for thickness are in µm; values for surface area in µm2.
A area, T thickness, U umbo, n nasal, t temporal.
Boxplots showing the retina thickness values of the right (a) and left (b) eyes. For each thickness coefficient, numerical data of Mauritius male, Mauritius female, Asian male, and Asian female are plotted. Rectangular boxes represent interquartile ranges (IQR), which extend from Q1 to Q3. A black line in the middle of an IQR indicates a median. Upper whiskers extend to the last datum, which is smaller than Q3 + 1.5 × IQR. Lower whiskers extend to the first datum, which is greater than Q1 − 1.5 × IQR. Data beyond whiskers are outliers and plotted as black circles.Boxplots of retina areas of the right (a) and left (b) eyes. For each area coefficient, numerical data of Mauritius male, Mauritius female, Asian male, and Asian female are plotted.Summary statistics of retina thickness values with respect to eye side, sex, and origin.Values are presented in µm.OD oculus dexter, OS oculus sinister, Std statistical analysis, U umbo, n nasal, t temporal.Summary statistics of retina areas with respect to eye side, sex, and origin.Values are presented in µm2.OD oculus dexter, OS oculus sinister, Std statistical analysis, U umbo, n nasal, t temporal.Summary subfield analysis of umbo retina thickness and area values.Values for thickness are in µm; values for surface area in µm2.A area, T thickness, U umbo, n nasal, t temporal.
Statistical analyses
Correlation analysis
Columns 1 to 8 in Table 4 reveal that the retina thickness and corresponding area coefficients (e.g., T1 and A1) are highly correlated (correlations between 0.89 and 0.96). Moreover, columns 9 to 12 in Table 4 show that all four umbo coefficients are highly correlated with T5 (correlations between 0.92 and 0.96). Regarding the correlations among the nine thickness coefficients of T1–T9, Table 5 demonstrates the generally rather high correlation between adjacent coefficients (0.55–0.91). However, for nonadjacent coefficients, this correlation is smaller (0.07–0.85). For statistical analyses, we considered only the nine thickness coefficients T1–T9, excluding the eighth area (A1–A8) and four umbo (TUn, TUt, AUn, and AUt) coefficients.
Table 4
Pearson correlation among thickness and area coefficients.
1
2
3
4
5
6
7
8
9
10
11
12
Var1
T1
T2
T3
T4
T6
T7
T8
T9
T5
T5
T5
T5
Var2
A1
A2
A3
A4
A5
A6
A7
A8
TUn
TUt
AUn
AUt
Corr
0.96
0.94
0.91
0.89
0.90
0.90
0.91
0.95
0.96
0.95
0.92
0.92
High correlations exist between thickness and corresponding area coefficients (e.g., T1 and A1) and between the four umbo coefficients (TUn, TUt, AUn, and AUT) and thickness T5.
Table 5
Pearson correlation matrix for thickness coefficients T1–T9.
T1
T2
T3
T4
T5
T6
T7
T8
T9
T1
1
0.91
0.71
0.35
0.07
0.29
0.55
0.63
0.58
T2
1
0.84
0.43
0.07
0.35
0.66
0.68
0.60
T3
1
0.71
0.25
0.59
0.79
0.58
0.46
T4
1
0.54
0.83
0.64
0.35
0.29
T5
1
0.59
0.33
0.10
0.13
T6
1
0.70
0.31
0.27
T7
1
0.74
0.61
T8
1
0.90
T9
1
Adjacent coefficients (e.g., T1 and T2) generally show a higher correlation than nonadjacent coefficients (e.g., T1 and T3). The lower triangle of the matrix has been left empty because the correlation matrix is symmetric.
Pearson correlation among thickness and area coefficients.High correlations exist between thickness and corresponding area coefficients (e.g., T1 and A1) and between the four umbo coefficients (TUn, TUt, AUn, and AUT) and thickness T5.Pearson correlation matrix for thickness coefficients T1–T9.Adjacent coefficients (e.g., T1 and T2) generally show a higher correlation than nonadjacent coefficients (e.g., T1 and T3). The lower triangle of the matrix has been left empty because the correlation matrix is symmetric.
Principal component analysis
A principal component analysis (PCA) was used to investigate the latent factors that could explain the variability in the thickness parameters T1–T9. The plots in Fig. 3 reveal that the first three principal components (PCs) explain 87.5% and 87.3% of the variability for the left and right eyes, respectively. That is, the first three PCs mainly determine the values of T1–T9. Table 6 shows the PCA coefficients of the first three PCs for the left and right eyes. The patterns for the left and right eyes are largely the same. The first PC is a weighted average of the nine thickness parameters, with the weights roughly corresponding to the relative size of each thickness. That is, the first PC is an overall thickness factor. The second PC appears to be considering the thickness values at the edges (negative sign) versus those at the center (positive sign). This suggests that the second PC is a center-vs.-edge factor. The third PC seems to be considering nasal versus temporal thickness parameters (mainly reversed signs for PCA coefficients left and right of T5). That is, the third PC is a nasal-vs.-temporal factor.
Figure 3
Principal component analysis (PCA) scree plots showing the cumulative eigenvalues of the nine principal components (PCs) for the right (a) and left (b) eyes. Eigenvalues correspond to the explained variability of the respective PC. The first three PCs explain 87.5% and 87.3% of the variability for the left and right eyes, respectively.
Table 6
Principal component coefficients of the first three principal components for left and right eyes.
PC
Eye
T1
T2
T3
T4
T5
T6
T7
T8
T9
1
Left
10.5
11.6
12.2
10.3
5.4
10.0
12.3
11.2
9.8
2
Left
− 5.6
− 4.8
0.2
7.2
9.7
7.9
1.1
− 4.9
− 5.2
3
Left
− 3.9
− 4.0
− 4.5
− 1.5
3.7
− 0.4
1.1
5.2
7.2
1
Right
10.8
11.6
12.3
9.9
5.1
9.0
12.2
10.7
10.1
2
Right
− 5.2
− 4.8
0.5
7.9
9.7
9.0
1.2
− 5.8
− 5.5
3
Right
4.0
4.4
4.7
1.3
− 3.8
− 0.1
− 1.6
− 5.6
− 6.6
Principal component analysis (PCA) coefficients of the first three principal components (PCs). The table shows the PCA coefficients for the left (three top rows) and right (three bottom rows) eyes. The patterns are largely the same for the left and right eyes. The first PC is an overall thickness factor with PCA coefficients of T1–T9 corresponding roughly to the relative size of the respective thickness. The second PC is a center-vs.-edge factor. The third PC is a nasal-vs.-temporal factor. The sign of the third PC is mostly reversed for the left and right eyes.
Principal component analysis (PCA) scree plots showing the cumulative eigenvalues of the nine principal components (PCs) for the right (a) and left (b) eyes. Eigenvalues correspond to the explained variability of the respective PC. The first three PCs explain 87.5% and 87.3% of the variability for the left and right eyes, respectively.Principal component coefficients of the first three principal components for left and right eyes.Principal component analysis (PCA) coefficients of the first three principal components (PCs). The table shows the PCA coefficients for the left (three top rows) and right (three bottom rows) eyes. The patterns are largely the same for the left and right eyes. The first PC is an overall thickness factor with PCA coefficients of T1–T9 corresponding roughly to the relative size of the respective thickness. The second PC is a center-vs.-edge factor. The third PC is a nasal-vs.-temporal factor. The sign of the third PC is mostly reversed for the left and right eyes.The multivariate analysis of variance (MANOVA) (Table 7) demonstrates that the independent variables of sex and origin have a significant impact on the dependent variables T1–T9 in both eyes. The effect of origin was stronger than the effect of sex. The interaction terms between sex and origin were not significant and, thus, were removed from the final models.
Table 7
Multivariate analysis of variance (MANOVA) results.
Eye
Variable
Wilks’ lambda
Pr > F
Left
Sex
0.8142
5.9e−5
Left
Origin
0.6454
1.9e−12
Right
Sex
0.8650
3.1e−3
Right
Origin
0.6257
1.4e−13
A MANOVA was performed for the left (first two rows) and right (bottom two rows) eyes separately. The independent variables of sex and origin have an effect on the dependent variables T1–T9 in left and right eyes. The effect of origin is stronger than the effect of sex. Effect size is measured using Wilks’ lambda. The test results are equivalent with Pillai's trace, Hotelling-Lawley trace, and Roy's greatest root.
Multivariate analysis of variance (MANOVA) results.A MANOVA was performed for the left (first two rows) and right (bottom two rows) eyes separately. The independent variables of sex and origin have an effect on the dependent variables T1–T9 in left and right eyes. The effect of origin is stronger than the effect of sex. Effect size is measured using Wilks’ lambda. The test results are equivalent with Pillai's trace, Hotelling-Lawley trace, and Roy's greatest root.
Analysis of variance
Table 8 shows the results of the nine two-way analysis of variance (ANOVA) analyses. Differences in sex are significant for the outer thickness parameters (T1–T3 and T7–T9), whereas differences in origin are significant for inner thickness values (T5 and T6). Interaction terms between sex and origin are not significant and, thus, have been removed from the final models.
Table 8
Summary of p-values in two-way analysis of variance (ANOVA) for measured retinal thickness parameters in left and right eyes in relation to sex and origin.
Thickness
T1
T2
T3
T4
T5
T6
T7
T8
T9
Sex
9.8e−04**
1.3e−04**
2.8e−03*
1.4e−04**
1.7e−06***
5.2e−07***
Origin
5.1e−10***
1.8e−06***
6.4e−03
Three stars indicate p-values < 0.001/9. Two stars indicate p-values < 0.01/9. One star and one dot indicate p-values < 0.05/9 and < 0.1/9, respectively. Nine is the number of hypotheses and, thus, the factor applied to adjust significance levels (Bonferroni correction). Exact p-values are only shown if the results are significant.
Summary of p-values in two-way analysis of variance (ANOVA) for measured retinal thickness parameters in left and right eyes in relation to sex and origin.Three stars indicate p-values < 0.001/9. Two stars indicate p-values < 0.01/9. One star and one dot indicate p-values < 0.05/9 and < 0.1/9, respectively. Nine is the number of hypotheses and, thus, the factor applied to adjust significance levels (Bonferroni correction). Exact p-values are only shown if the results are significant.
Discussion
The main aim of the current study was to generate reference data on a large number of cynomolgus macaque eyes (M. fascicularis)[26,27], which, because of their genetic similarity to humans, have been successfully introduced into biomedical research[28-33]. Alongside histopathologic examinations[31,34], OCT has been demonstrated as a useful imaging tool to assess ocular toxicity, such as for ocular inflammation, in preclinical studies[24,33,35,36].Despite all the successes, OCT remains a fairly new technique in animal research, which may account for the lack of reference data. In addition, the analysis of OCT scans from cynomolgus macaques is time-consuming and associated with undesired deviations because of the often manually—thus relatively arbitrary—performed readings of the values[37,38]. Consequently, interpreting such OCT results in the context of the natural variability of macular thickness is impossible.To overcome these limitations and offer more in-depth knowledge compared with our previous report[39], the present study successfully implemented an automatic machine learning application that was supplemented with a classic approach in a hitherto unprecedented number of cynomolgus monkeys. Their retinal thickness at the fovea—or the site of highest visual acuity—was assessed to provide reference values. Despite morphological similarities among the eyes of most primates, the obtained data show that in addition to the known differences in the cone numbers[40-42], corresponding variations can also be found at the structural OCT level. These variations occur even within the same species of different geographic origins, which are commonly used in preclinical toxicology studies[43]. This circumstance was also evident in the subanalysis of the umbo area, that is, the site with the highest density of photoreceptors (cones). The integrity of this zone is essential for the best visual acuity, and its disintegration can be the first sign of various diseases, such as age-related macular degeneration, but also, for example, the formation of a macular hole[21]. Our data suggest that despite being the same species, certain morphological characteristics have evolved differently. It is important to be aware of this fact, particularly if, during drug development, researchers decide to alternate trials between monkeys of different origins. Consequently, both origins cannot necessarily be used interchangeably in each use case. This particular difference in macular morphology would be the most relevant if we relied on quantitative macula measurements.The metabolic differences between Asian and Mauritian macaques have been investigated and described previously[42]. As an example, it has been shown that in Mauritius macaques, the retroviral restriction factor TRIMCyp is not present, which is in contrast to a higher expression of TRIMCyp in Indonesian macaques, causing methodological challenges for AIDS research[44]. However, so far, no data have been available for ocular structure.In agreement with a previous study, there was no significant difference in the central depression (T4, T5, and T6) between the sexes[39]. Interestingly, individual ANOVA analyses of the data show significant differences in nasal and temporal thickness values (T1–T3 and T7–T9, respectively) between male and female individuals. This suggests that the averaged values of macula measurements, which are commonly used in ophthalmic research and obtained over a larger range, underestimate local variations, so caution is advised in interpreting these values. Overall, females showed a slightly thinner retina than males—which is similar to humans—although major differences between the provenances and age might also have to be taken into account[45-47].The mean overall retina thickness in the present study was 199 µm, compared with 244 µm in cynomolgus macaques[39] and 305 µm in humans[48]. This deviation can be explained by the fact that in comparable cynomolgus monkey studies, the value was determined over a larger subfield, which is in contrast to the current subfield study that only calculated the values from the deepest point within the foveola. Regarding minimal foveal thickness, an unpublished study (Vilupuru A. Optical coherence tomography in normal eyes of rhesus monkeys. American Academy of Optometry, 2005) using Stratus time-domain OCT (TD-OCT) measured a value that was approximately 60 µm lower. However, considerable deviations between generations of OCT devices and better reproducibility for the spectral-domain system used in the present study have been reported[49,50]. Furthermore, the number of animals was several times higher in the present study. In summary, a final appreciation of the mentioned TD-OCT data is not feasible because the methodology and values have not been made publicly available in full detail.The current study may be limited because the axial length and refractive status were not known, and diurnal variations have not been measured yet. However, such limits are often inherent in retrospective studies and can be complemented in future prospective studies. Of course, the definition of the reference position nulla can be a point of discussion and may represent an additional limit to naturally occurring variations[51]. Using the suggested fully automatic image processing method, human selection bias with regard to the position of nulla can be largely eliminated or even prevented. Another limitation could be that in the accumulated database, no repeated retina measurements were available. However, for repeated retina OCT measurements, only minor variations were found that were within the resolution and repeatability range of the OCT devices[52,53].The current number of B-scans may not have captured the effective fovea center in every single eye. In addition, the analyzed region does not correspond to the whole retina, so conclusions can only be derived for the central retina. Nevertheless, the reference database covers the area of greatest cell density[54,55].In summary, for the first time, the current study succeeded in applying a hybrid machine learning approach to a large number of macaque eyes to determine the reference values for retinal thickness at the fovea. In addition, the present study has described the morphological variability of retinal thickness and how it relates to sex and the origin of these monkeys. Most importantly, the present study has shown that a thorough awareness of the constraining elements in model species supports the careful selection of the appropriate models for ophthalmic research and appropriate reading of the obtained data. The data provided are important for earlier and more sensitive detection, quantification, and characterization of toxic ocular effects in preclinical safety studies[56,57]. In particular, noninvasive OCT examinations can constitute an additional imaging method for comparative studies between OCT and histopathology[58,59]. However, compared with histology[60], which is usually performed only once, OCT can be performed within seconds and as often as needed, all without damaging the ocular tissue or bloodstream. Consequently, OCT appears to be an ideal instrument for longitudinal investigations and can presumably enable better characterization and monitoring of lesions.
Methods
Animals
All experiments were performed in accordance with the relevant guidelines and regulations. Data were acquired from healthy, untreated cynomolgus monkeys (Macaca fascicularis) during ocular baseline examinations of routine pharmaceutical product development studies. Thus, no additional animals were used specifically for the current study. Animal care and experimentation were in accordance with the guidelines of the Association for Assessment and Accreditation of Laboratory Animal Care (AAALAC), ARRIVE guidelines, the US National Research Council, and/or the Canadian Council on Animal Care (CCAC). The studies were approved by one of the following Institutional Animal Care and Use Committees (IACUCs): Charles River Laboratories Montreal, ULC Institutional Animal Care and Use Committee (CR-MTL IACUC), IACUC Charles River Laboratories Reno (OLAW Assurance No. D16-00594), and Institutional Animal Care and Use Committee (Covance Laboratories Inc., Madison, WI) (OLAW Assurance #D16-00137 (A3218-01)). The protocols for the original drug development studies were reviewed and approved by the respective Institutional Animal Care and Use Committees of their respective contract research organizations.The animals were group-housed in stainless steel cages according to European housing standards (Annex III of Directive 2010/63/EU). The temperature of the animal room was maintained between 20 and 26 °C, with humidity between 30 and 70%. The light cycle was 12 h light and 12 h dark, except during designated procedures. The animals were fed a standard diet of pellets supplemented with fresh fruits and vegetables. Water treated with reverse osmosis and ultraviolet irradiation was freely available to each animal via an automated watering system. Psychological and environmental enrichment was provided to the animals, except during study procedures and activities. The animals were purpose-bred and of Mauritian or mixed Asian origin (the exact geographical location for the latter is unknown).OCT scans were obtained from 374 eyes of 203 animals. Information regarding age was available for 159 subjects, with an overall mean age of 4.98 years (range 2.5–5 years). Females contributed 147 eyes (39.30%) and males 227 eyes (60.70%); of the total eyes, 186 were left eyes (47.74%), and 188 (50.26%) were right eyes. Regarding the geographic region, 199 eyes originated from Mauritius (53.20%), and 159 eyes were derived from Asia (46.80%). Sixteen eyes were of unknown origin, but the sex was defined.
Inclusion and exclusion criteria
The inclusion criteria were healthy and untreated cynomolgus monkeys derived from Mauritius or Asian origin who were between 30 and 50 months of age and weighed between 2.5 and 5.5 kg. Only healthy eyes, with optically clear ocular media and no observed anterior or posterior segment pathologies, were included in the study. Eyes of an undocumented sex, origin, or eye side were excluded from the subanalyses.
OCT imaging
OCT was performed under general anesthesia with dilated pupils using spectral-domain OCT on the Spectralis HRA + OCT Heidelberg platform (Heidelberg Engineering, Heidelberg, Germany) as reported[37,39]. The same scan protocol was selected for all animals with a horizontal line scan pattern (centered over the fovea) with a size of 20° × 20°, 25 raster lines separated by 221 μm (scan length 5.3 mm, 512 × 496 pixels, scan depth 1.9 mm). The data were exported directly from the OCT device as original B-scan files in a bitmap image data (BMP) format using the manufacturer’s software.
The fovea position–location problem
Because the examined animals for obvious reasons could not follow the instructions of the operator to exactly and steadily fixate on a presented target, the determination of the fovea center by an OCT operator could be relatively arbitrary. The use of subjective criteria for the definition of the fovea may affect the preciseness of a measurement[61]. Although the term fovea is frequently used in the clinical context, it does not represent a precise anatomical term or position, so the determination of fovea landmarks may be associated with uncertainties[55,62].Currently, a concaviclivate fovea (fovea from the Latin “ditch” or “pit”) represents a depression of the center of the retina[9] (Fig. 4). Thereby, a supposed margin can be assumed, which transits into a descending clivus or slope (clivus from the Latin “slope” or “hill”), resulting in a certain bowl-shaped configuration. The base is referred to as the foveola or “little fovea.” Although the umbo is interpreted clinically as the center of the fovea, such a definition proves to be rather problematic in cross-sectional imaging in animals because the geometry and extension of the fovea differ remarkably among different species[55].
Figure 4
Definition of anatomical foveolar landmarks. (a) A cross-sectional optical coherence tomography (OCT) of the right concaviclivate fovea in a healthy macaque is shown. (b) A schematic overlay of the same scan illustrating the anatomical landmarks. The area of the fovea is characterized as a central depression (single arrows) descending in a more or less symmetrical curvilinear shape (double arrowheads) to the bottom, which is named the foveola. The deepest location inside the fovea is determined as the nulla (marked as a red dot) and represents an OCT-based anatomical landmark. The umbo in the OCT image is designated as the proposed center of the fovea (highlighted as the green area between the two arrows) near the nulla at a distance of 100 µm to each side. Based on these conventions, the following OCT-based sequence can be proposed: macula lutea > perifovea > parafovea > fovea > foveola > umbo > nulla. The retinal pigment epithelium is highlighted in blue.
Definition of anatomical foveolar landmarks. (a) A cross-sectional optical coherence tomography (OCT) of the right concaviclivate fovea in a healthy macaque is shown. (b) A schematic overlay of the same scan illustrating the anatomical landmarks. The area of the fovea is characterized as a central depression (single arrows) descending in a more or less symmetrical curvilinear shape (double arrowheads) to the bottom, which is named the foveola. The deepest location inside the fovea is determined as the nulla (marked as a red dot) and represents an OCT-based anatomical landmark. The umbo in the OCT image is designated as the proposed center of the fovea (highlighted as the green area between the two arrows) near the nulla at a distance of 100 µm to each side. Based on these conventions, the following OCT-based sequence can be proposed: macula lutea > perifovea > parafovea > fovea > foveola > umbo > nulla. The retinal pigment epithelium is highlighted in blue.
Definition of nulla as an OCT structure-based fovea parameter
The fovea can be visualized very well with an excavation of the central retina on OCT imaging (Fig. 4a). To eliminate the position–location problem of the fovea toward an objective assessment and in a slight customization to previous reports[51,55] where the deepest point of the foveal pit was indicated, a modified interpretation of the deepest position within the retina is proposed based on structural OCT information.For this purpose, an automatic fovea depression contour finder approach was pursued, in which the definition of the particular fovea center (displayed on the OCT-B scan) was defined as the deepest point within the foveolar cavity (Fig. 4b). The resulting position was referred to as the nulla, which implies that on the particular B-scan or a stack of B-scans no deeper excavation could be present below the nulla within a fovea. The retinal thickness at the nulla position corresponds to the thinnest retinal thickness within the pit or inner fovea, where the incident light can interact most directly with the photoreceptors. This position holds an important value because the area within 150–200 µm around the nulla represents a crucial site containing the highest concentration of photoreceptors (cones)[55].
Semantic image segmentation
The algorithm developed for the objective identification of the nulla and subsequent measurement of retina thicknesses and areas consists of six steps, which are illustrated in Figs. 5 and 6. The first step is the generation of pixel-wise semantic segmentation maps of the retina compartment using a convolutional neural network (CNN) for each B-scan (Fig. 5). The CNN was developed and described in detail in a previous study[63]. In summary, it uses a modified U-Net architecture[64] with 22 convolutions, 5 transposed convolutions, and 5 skip connections, which have previously been shown to also be highly effective in learning semantic segmentation maps from human OCT B-scans[61]. The CNN was trained and validated on a representative subset of the OCT cynomolgus monkey data set[39] used in the current work. This subset—the ground truth—consisted of a total of 1100 B-scans (44 eyes from 44 individuals, each eye contributing 25 B-scans). For each individual, either the left or right eye was included. The ground truth was annotated by three experienced and independent retina specialists and randomly split into training, validation, and test sets of 675, 225, and 200 B-scans, respectively. For the training and validation sets, each human grader annotated 225 and 75 different B-scan, respectively. The test set of 200 B-scans was annotated by each human grader to investigate the intergrader agreement of the ground truth labels. Training set data were augmented by applying to each B-scan (1) vertical mirroring and (2) adding a random rotation between − 8° and 8° degrees, increasing the training set size to 2025 B-scans. Regarding CNN training, the model parameters were initialized[65] and learned by minimizing an unweighted pixel-wise cross-entropy loss summed over the entire input. Adam optimization was used on a single NVIDIA TITAN-X GPU[66,67]. An initial learning rate of 6 × 10−5 and a mini-batch size of eight images was chosen, which had proven suitable in preliminary experiments. Training was stopped after 1920 iterations (7.6 epochs) after the validation set accuracy reached a plateau. On the test set, the differences between the CNN’s predictions and the annotations of the three human graders were, on average, smaller than the intergrader differences. The algorithm’s input are B-scans (Fig. 5a), here rescaled to 512 × 512 pixels and with its output corresponding pixel-wise semantic segmentation maps of the compartments vitreous, retina, choroid, and sclera (Fig. 5b). For the current study, only the retina compartment segmentations were further processed (Fig. 5c). The retinal inner boundary was defined as the transition from the hyporeflective vitreous to the hyperreflective retinal nerve fiber layer, more specifically in the area of the ILM. The retinal outer border was defined as the outer demarcation zone of the hyperreflective retinal pigment epithelium, just above the hyporeflective zone of the choriocapillaris. Detailed CNN architecture is shown in Fig. 2 of Maloca et al. (2019)[68]. See the previous study for further details about ground truth annotation, CNN training, and CNN evaluation[63].
Figure 5
Illustration of the semantic compartment annotations. (a) An original cross-sectional B-scan was exported for (b) automatic machine learning compartmentalization of the posterior eye segment into the vitreous (arrow, marked in brown), retina (double-closed arrowhead, marked in blue), and choroid (double-open arrowhead, marked in orange). (c) The resulting retina component (blue, double-open arrowhead) was used for further analyses in one and two dimensions.
Figure 6
Illustration of the image processing pipeline that consists of six steps. First, a raw B-scan is used as input to a modified U-Net[64]. The output is a semantic segmentation map. In between, 11 network layers are schematically visualized, including the network’s five skip connections (indicated by black arrows)[61,63]. Second, segmentation artifacts are removed. Third, the region of the internal limiting membrane (ILM) separating vitreous from retina is identified (black line). Fourth, the ILM is smoothed (black line). Fifth, the nulla (red dot) is identified on the smoothed ILM. Sixth, retina thicknesses and areas are measured (violet bars).
Illustration of the semantic compartment annotations. (a) An original cross-sectional B-scan was exported for (b) automatic machine learning compartmentalization of the posterior eye segment into the vitreous (arrow, marked in brown), retina (double-closed arrowhead, marked in blue), and choroid (double-open arrowhead, marked in orange). (c) The resulting retina component (blue, double-open arrowhead) was used for further analyses in one and two dimensions.Illustration of the image processing pipeline that consists of six steps. First, a raw B-scan is used as input to a modified U-Net[64]. The output is a semantic segmentation map. In between, 11 network layers are schematically visualized, including the network’s five skip connections (indicated by black arrows)[61,63]. Second, segmentation artifacts are removed. Third, the region of the internal limiting membrane (ILM) separating vitreous from retina is identified (black line). Fourth, the ILM is smoothed (black line). Fifth, the nulla (red dot) is identified on the smoothed ILM. Sixth, retina thicknesses and areas are measured (violet bars).
Segmentation artifact removal
The second algorithmic step is the removal of segmentation artifacts. A small number of semantic segmentation maps contained small patches of misclassified regions, that is, segmentation artifacts. The CNN output in Fig. 6 shows an example of two such misclassified choroid regions in the sclera compartment. These segmentation artifacts were corrected by the following approach: in a segmentation map, the four main compartments (vitreous, retina, choroid, and sclera) are expected to form large, connected regions. This is true even in the presence of segmentation artifacts. Thus, the four largest connected regions generally correspond to the vitreous, retina, choroid, and sclera compartments. If additional connected regions are present, they must represent segmentation artifacts. If a segmentation artifact is completely surrounded by a compartment, the artifact can be removed by replacing it with the label of the surrounding compartment. Because the segmentation artifacts were small and did not occur at the compartment borders, they were effectively removed using this approach.
Nulla identification
The third algorithmic step is the identification of the ILM (the border between vitreous and retina) from the semantic segmentation map (Fig. 6). This approach generally yielded noisy ILMs, which did not allow for a reliable identification of the lowest point: the nulla. Therefore, in a fourth algorithmic step, the identified ILM was smoothed using a moving average, with the moving average window being applied in two dimensions simultaneously: in the B-scan width dimension (window size 11) and B-scan “stack” dimension (window size 5). Afterwards, the fifth algorithmic step identified the lowest point on the smoothed internal limiting membrane (Fig. 6). If multiple lowest points were found (usually adjacent), the coordinates of their center of mass were used as the lowest point and, if necessary, rounded to the coordinates of the voxel nearest to it. By utilizing this approach, the “central” B-scan was identified, along with the pixel coordinates of the nulla.
Retinal thicknesses and areas
The sixth algorithmic step is the measurement of retinal thicknesses and its areas. Using the semantic segmentation of the retina compartment on the central B-scan and the position of the anatomically and structured OCT-determined nulla, an imaginary line was orthogonally positioned in relation to the underlying retinal pigment epithelium to determine the axial diameter (Fig. 7). Subsequent measurements of retinal values were made at intervals of 500 µm to the side, up to a maximum of 2000 µm distance from the nulla. This allowed for measurements of nine retinal diameters (marked as thickness parameters T1–T9) in the axial direction, as well as eight intervening retinal areas (A1–A8), hence providing a total of 17 parameters to quantify the retina features (Fig. 7).
Figure 7
One- and two-dimensional retina parameters are illustrated in a left retina. From the anatomically deepest location within the foveolar cavity (marked as nulla, red dot) and orthogonally to the retinal pigment epithelium, side-by-side measurements were taken at 500 µm intervals starting nasally toward the temporal retina with respect to the axial retina diameters (a) (shown as pink lines and marked as retinal thickness parameters T1–T9) and the retinal surface areas (b) in between (highlighted in red and marked as areas A1–A8). Subfield analyses included the regions at a distance of 100 µm from nulla (highlighted with white lines and umbo surface area in green). The same procedure was performed for all eyes. For a better understanding, the segmented retina is depicted as a blue overlay. Scale bars, 500 µm.
One- and two-dimensional retina parameters are illustrated in a left retina. From the anatomically deepest location within the foveolar cavity (marked as nulla, red dot) and orthogonally to the retinal pigment epithelium, side-by-side measurements were taken at 500 µm intervals starting nasally toward the temporal retina with respect to the axial retina diameters (a) (shown as pink lines and marked as retinal thickness parameters T1–T9) and the retinal surface areas (b) in between (highlighted in red and marked as areas A1–A8). Subfield analyses included the regions at a distance of 100 µm from nulla (highlighted with white lines and umbo surface area in green). The same procedure was performed for all eyes. For a better understanding, the segmented retina is depicted as a blue overlay. Scale bars, 500 µm.An additional subanalysis in the important area of the umbo was performed to determine the parameters for the most central receptors, which are responsible for the best visual acuity (central bouquet of cones)[41,51]. For this purpose, the thickness values and retina intervening surface areas were each determined laterally at an interval of 100 µm to the nulla. Thus, four further parameters were added: one additional nasal thickness (TUn), one temporal thickness (TUt), and two additional retinal surface areas from the nasal (AUn) and temporal (AUt) retina areas. Finally, including T5 (also indicated as the nulla), the umbo subfield analysis used a total of five parameters.The first algorithmic step was performed in Python v3.5 and TensorFlow v1.14.0[69]. Steps two to six were performed in C# (v7.0, NET Framework v4.6). The combination of CNN-based semantic image segmentation with a fully automated fovea-finding algorithm, which is based on classical computer vision, can be described as “hybrid image processing.”
Data analysis
Summary statistics and visualization
The summary statistics of the mean, minimum, and maximum were calculated for each of the measured retinal thickness and area coefficients on subsets of the data. Boxplots were used to visualize the distribution of the data and compare the two groups with each other (e.g., male vs. female). For the nulla, its retina diameter (T5), its adjacent retina surfaces (A4 and A5), and the average mean values were calculated for all eyes and both sexes.
Statistical analyses
Statistical analyses were performed (1) to investigate the observed variability in the data and (2) investigate differences with respect to sex and origin. The statistical analyses consisted of four parts.First, a Pearson correlation analysis was performed to investigate the correlation among the 11 thickness and 10 area coefficients. As a result of the high correlation between (1) the thickness and area coefficients and between (2) the umbo subanalysis coefficients and T5, it was decided to include only the nine thickness coefficients T1–T9 in subsequent statistical analyses. For the Pearson correlation analysis, the left and right eyes were combined. Separate analyses of the left and right eyes yielded results almost identical to the results of the left and right eyes combined.Second, a principal component analysis (PCA) was performed separately for the left and right eyes[70]. PCA does not provide insights into the effects of the independent variables of sex and origin but can identify the latent factors underlying the variability observed in T1–T9. Scree plots were used to visualize the eigenvalues of each PC. Each eigenvalue corresponds to the amount of variability explained by the corresponding PC. PCA coefficients are shown for the first three PC.Third, a two-way MANOVA[71] was used to jointly investigate the effects of the independent variables of sex and origin on T1–T9. MANOVA assumptions were checked with diagnostic plots (not shown). One multivariate outlier was removed from the group of right eyes. Wilks’ lambda was used to measure the impact of sex and origin. The MANOVA was separately calculated for the left and right eyes.Fourth, two-way ANOVA tests were used to investigate the effects of sex and origin for each coefficient T1–T9 individually. The coefficients T1–T9 are obviously correlated with each other and, thus, not independent. Consequently, the ANOVA results are not independent of each other, and the p-values might be inaccurate. Nevertheless, we decided to perform individual ANOVA analyses because it allowed us to gain insights into which parts of the retina are responsible for the differences between male and female and Asian and Mauritius monkeys. To adjust for multiple testing, we performed Bonferroni corrections by dividing the significance levels by the number of tests, which was nine in our case. Variables that were significant at p < 0.001/9 are indicated with “***.” Variables that were significant at p < 0.01/9 are indicated with “**,” and variables that were significant at p < 0.05/9 are indicated with “*.” Finally, variables that were significant at p < 0.1/9 are indicated with “.”. ANOVA assumptions were checked with the diagnostic plots (not shown). ANOVA tests were performed separately for the left and right eyes.The 374 eyes contained 16 eyes of an unknown origin, which were excluded from the MANOVA and ANOVA analyses. Some monkeys contributed a left eye and right eye. Thus, the left and right eyes are not independent of each other. Consequently, PCA, MANOVA, and ANOVA analyses were performed for the left and right eyes separately. All summary statistics, data visualizations, and statistical analyses were performed in Python v3.8.5. PCA and statistical tests were performed with the Python package statsmodels v0.12.1. Visualizations were generated using the Python package Matplotlib v3.3.2.Supplementary Information.
Authors: Lin He; Ruojin Ren; Hongli Yang; Christy Hardin; Luke Reyes; Juan Reynaud; Stuart K Gardiner; Brad Fortune; Shaban Demirel; Claude F Burgoyne Journal: PLoS One Date: 2014-03-18 Impact factor: 3.240
Authors: Soohyun Kim; Jennifer J Kang-Mieler; Wenqiang Liu; Zhe Wang; Glenn Yiu; Leandro B C Teixeira; William F Mieler; Sara M Thomasy Journal: Transl Vis Sci Technol Date: 2020-02-27 Impact factor: 3.283
Authors: Nora Denk; Peter Maloca; Guido Steiner; Christian Freichel; Simon Bassett; Tobias K Schnitzer; Pascal W Hasler Journal: PLoS One Date: 2019-10-07 Impact factor: 3.240
Authors: Richard P Gale; Ian Pearce; Nicole Eter; Faruque Ghanchi; Frank G Holz; Steffen Schmitz-Valckenberg; Konstantinos Balaskas; Ben J L Burton; Susan M Downes; Haralabos Eleftheriadis; Sheena George; David Gilmour; Robin Hamilton; Andrew J Lotery; Nishal Patel; Priya Prakash; Cynthia Santiago; Saju Thomas; Deepali Varma; Gavin Walters; Michael Williams; Armin Wolf; Rosina H Zakri; Franklin Igwe; Filis Ayan Journal: Br J Ophthalmol Date: 2019-08-05 Impact factor: 4.638
Authors: Peter M Maloca; Christian Freichel; Christof Hänsli; Philippe Valmaggia; Philipp L Müller; Sandrine Zweifel; Christine Seeger; Nadja Inglin; Hendrik P N Scholl; Nora Denk Journal: Sci Rep Date: 2022-08-02 Impact factor: 4.996
Authors: Peter M Maloca; Philippe Valmaggia; Theresa Hartmann; Marlene Juedes; Pascal W Hasler; Hendrik P N Scholl; Nora Denk Journal: PLoS One Date: 2022-09-23 Impact factor: 3.752