Literature DB >> 34637140

Ultrasound guidance for arterial (other than femoral) catheterisation in adults.

Ronald Lg Flumignan1, Virginia Fm Trevisani2,3, Renato D Lopes4, Jose Cc Baptista-Silva1,5, Carolina Dq Flumignan1, Luis Cu Nakano1.   

Abstract

BACKGROUND: Arterial vascular access is a frequently performed procedure, with a high possibility for adverse events (e.g. pneumothorax, haemothorax, haematoma, amputation, death), and additional techniques such as ultrasound may be useful for improving outcomes. However, ultrasound guidance for arterial access in adults is still under debate.
OBJECTIVES: To assess the effects of ultrasound guidance for arterial (other than femoral) catheterisation in adults. SEARCH
METHODS: We searched CENTRAL, MEDLINE, Embase, LILACS, and CINAHL on 21 May 2021. We also searched IBECS, WHO ICTRP, and ClinicalTrials.gov on 16 June 2021, and we checked the reference lists of retrieved articles. SELECTION CRITERIA: Randomised controlled trials (RCTs), including cross-over trials and cluster-RCTs, comparing ultrasound guidance, alone or associated with other forms of guidance, versus other interventions or palpation and landmarks for arterial (other than femoral) guidance in adults. DATA COLLECTION AND ANALYSIS: Two review authors independently performed study selection, extracted data, assessed risk of bias, and assessed the certainty of evidence using GRADE. MAIN
RESULTS: We included 48 studies (7997 participants) that tested palpation and landmarks, Doppler auditory ultrasound assistance (DUA), direct ultrasound guidance with B-mode, or any other modified ultrasound technique for arterial (axillary, dorsalis pedis, and radial) catheterisation in adults. Radial artery Real-time B-mode ultrasound versus palpation and landmarks Real-time B-mode ultrasound guidance may improve first attempt success rate (risk ratio (RR) 1.44, 95% confidence interval (CI) 1.29 to 1.61; 4708 participants, 27 studies; low-certainty evidence) and overall success rate (RR 1.11, 95% CI 1.06 to 1.16; 4955 participants, 28 studies; low-certainty evidence), and may decrease time needed for a successful procedure (mean difference (MD) -0.33 minutes, 95% CI -0.54 to -0.13; 4902 participants, 26 studies; low-certainty evidence) up to one hour compared to palpation and landmarks. Real-time B-mode ultrasound guidance probably decreases major haematomas (RR 0.35, 95% CI 0.23 to 0.56; 2504 participants, 16 studies; moderate-certainty evidence). It is uncertain whether real-time B-mode ultrasound guidance has any effect on pseudoaneurysm, pain, and quality of life (QoL) compared to palpation and landmarks (very low-certainty evidence). Real-time B-mode ultrasound versus DUA One study (493 participants) showed that real-time B-mode ultrasound guidance probably improves first attempt success rate (RR 1.35, 95% CI 1.11 to 1.64; moderate-certainty evidence) and time needed for a successful procedure (MD -1.57 minutes, 95% CI -1.78 to -1.36; moderate-certainty evidence) up to 72 hours compared to DUA. Real-time B-mode ultrasound guidance may improve overall success rate (RR 1.13, 95% CI 0.99 to 1.29; low-certainty evidence) up to 72 hours compared to DUA. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Real-time B-mode ultrasound versus modified real-time B-mode ultrasound Real-time B-mode ultrasound guidance may decrease first attempt success rate (RR 0.68, 95% CI 0.55 to 0.84; 153 participants, 2 studies; low-certainty evidence), may decrease overall success rate (RR 0.93, 95% CI 0.86 to 1.01; 153 participants, 2 studies; low-certainty evidence), and may lead to no difference in time needed for a successful procedure (MD 0.04 minutes, 95% CI -0.01 to 0.09; 153 participants, 2 studies; low-certainty evidence) up to one hour compared to modified real-time B-mode ultrasound guidance. It is uncertain whether real-time B-mode ultrasound guidance has any effect on major haematomas compared to modified real-time B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. In-plane versus out-of-plane B-mode ultrasound In-plane real-time B-mode ultrasound guidance may lead to no difference in overall success rate (RR 1.00, 95% CI 0.96 to 1.05; 1051 participants, 8 studies; low-certainty evidence) and in time needed for a successful procedure (MD -0.06 minutes, 95% CI -0.16 to 0.05; 1134 participants, 9 studies; low-certainty evidence) compared to out-of-plane B-mode ultrasound up to one hour. It is uncertain whether in-plane real-time B-mode ultrasound guidance has any effect on first attempt success rate or major haematomas compared to out-of-plane B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. DUA versus palpation and landmarks DUA may lead to no difference in first attempt success rate (RR 1.01, 95% CI 0.90 to 1.14; 666 participants, 2 studies; low-certainty evidence) or overall success rate (RR 0.99, 95% CI 0.92 to 1.07; 666 participants, 2 studies; low-certainty evidence) and probably increases time needed for a successful procedure (MD 0.45 minutes, 95% CI 0.20 to 0.70; 500 participants, 1 study; moderate-certainty evidence) up to 72 hours compared to palpation and landmarks. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Oblique-axis versus long-axis in-plane B-mode ultrasound Oblique-axis in-plane B-mode ultrasound guidance may increase overall success rate (RR 1.27, 95% CI 1.05 to 1.53; 215 participants, 2 studies; low-certainty evidence) up to 72 hours compared to long-axis in-plane B-mode ultrasound. It is uncertain whether oblique-axis in-plane B-mode ultrasound guidance has any effect on first attempt success rate, time needed for a successful procedure, and major haematomas compared to long-axis in-plane B-mode ultrasound. Pseudoaneurysm, pain, and QoL were not reported. We are uncertain about effects in the following comparisons due to very low-certainty evidence and unreported outcomes: real-time B-mode ultrasound versus palpation and landmarks (axillary and dorsalis pedis arteries), real-time B-mode ultrasound versus near-infrared laser (radial artery), and dynamic versus static out-of-plane B-mode ultrasound (radial artery). AUTHORS'
CONCLUSIONS: Real-time B-mode ultrasound guidance may improve first attempt success rate, overall success rate, and time needed for a successful procedure for radial artery catheterisation compared to palpation, or DUA. In addition, real-time B-mode ultrasound guidance probably decreases major haematomas compared to palpation. However, we are uncertain about the evidence on major haematomas and pain for other comparisons due to very low-certainty evidence and unreported outcomes. We are also uncertain about the effects on pseudoaneurysm and QoL for axillary and dorsalis pedis arteries catheterisation. Given that first attempt success rate and pseudoaneurysm are the most relevant outcomes for people who underwent arterial catheterisation, future studies must measure both. Future trials must be large enough to detect effects, use validated scales, and report longer-term follow-up.
Copyright © 2021 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2021        PMID: 34637140      PMCID: PMC8507521          DOI: 10.1002/14651858.CD013585.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  98 in total

1.  The Seldinger technique: 50 years on.

Authors:  Z C J Higgs; D A L Macafee; B D Braithwaite; C A Maxwell-Armstrong
Journal:  Lancet       Date:  2005-07-20       Impact factor: 79.321

2.  Ultrasonographically Guided Puncture of the Radial Artery for Blood Gas Analysis: A Prospective, Randomized Controlled Trial.

Authors:  Christian B Laursen; Rasmus Lydum Pedersen; Annmarie Touborg Lassen
Journal:  Ann Emerg Med       Date:  2015-05       Impact factor: 5.721

3.  [Application of radial arterial puncture cannulation under ultrasonic guidance in patients with critical diseases].

Authors:  Lan Cao; Lina Zhang; Meilin Ai; Li Li; Dun Tian; Yang Sun; Luxi Deng
Journal:  Zhong Nan Da Xue Xue Bao Yi Xue Ban       Date:  2018-04-28

4.  Forty-five degree wrist angulation is optimal for ultrasound guided long axis radial artery cannulation in patients over 60 years old: a randomized study.

Authors:  Ahmet Kucuk; Hasan Husnu Yuce; Funda Yalcin; Fatıma Nurefsan Boyacı; Sema Yıldız; Saban Yalcin
Journal:  J Clin Monit Comput       Date:  2014-01-11       Impact factor: 2.502

5.  Comparison of Mill Suss™-guided radial artery catheterization with the long-axis in-plane ultrasound-guided method under general anesthesia: a randomized controlled trial.

Authors:  Michiko Osuda; Mitsutaka Edanaga; Tomomi Matsumoto; Asuka Yamamoto; Saki Ihara; Satoru Tanaka; Michiaki Yamakage
Journal:  J Anesth       Date:  2020-02-24       Impact factor: 2.078

6.  Real-time ultrasound guidance facilitates femoral arterial access and reduces vascular complications: FAUST (Femoral Arterial Access With Ultrasound Trial).

Authors:  Arnold H Seto; Mazen S Abu-Fadel; Jeffrey M Sparling; Soni J Zacharias; Timothy S Daly; Alexander T Harrison; William M Suh; Jesus A Vera; Christopher E Aston; Rex J Winters; Pranav M Patel; Thomas A Hennebry; Morton J Kern
Journal:  JACC Cardiovasc Interv       Date:  2010-07       Impact factor: 11.195

7.  2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation: The Task Force for the management of acute myocardial infarction in patients presenting with ST-segment elevation of the European Society of Cardiology (ESC).

Authors:  Borja Ibanez; Stefan James; Stefan Agewall; Manuel J Antunes; Chiara Bucciarelli-Ducci; Héctor Bueno; Alida L P Caforio; Filippo Crea; John A Goudevenos; Sigrun Halvorsen; Gerhard Hindricks; Adnan Kastrati; Mattie J Lenzen; Eva Prescott; Marco Roffi; Marco Valgimigli; Christoph Varenhorst; Pascal Vranckx; Petr Widimský
Journal:  Eur Heart J       Date:  2018-01-07       Impact factor: 29.983

8.  Trends in the prevalence and outcomes of radial and femoral approaches to percutaneous coronary intervention: a report from the National Cardiovascular Data Registry.

Authors:  Sunil V Rao; Fang-Shu Ou; Tracy Y Wang; Matthew T Roe; Ralph Brindis; John S Rumsfeld; Eric D Peterson
Journal:  JACC Cardiovasc Interv       Date:  2008-08       Impact factor: 11.195

9.  Ultrasound guidance for radial artery catheterization: an updated meta-analysis of randomized controlled trials.

Authors:  Lu Tang; Fei Wang; Yuxiang Li; Liang Zhao; Huijun Xi; Zhihong Guo; Xiuyun Li; Chengjie Gao; Jian Wang; Lingjun Zhou
Journal:  PLoS One       Date:  2014-11-06       Impact factor: 3.240

10.  Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors: A Randomized Trial.

Authors:  Quan Zhefeng; Chao Luo; Liang Zhang; Xin Li; Haili He; Ping Chi
Journal:  Med Sci Monit       Date:  2019-02-28
View more
  1 in total

Review 1.  Ultrasound guidance for arterial (other than femoral) catheterisation in adults.

Authors:  Ronald Lg Flumignan; Virginia Fm Trevisani; Renato D Lopes; Jose Cc Baptista-Silva; Carolina Dq Flumignan; Luis Cu Nakano
Journal:  Cochrane Database Syst Rev       Date:  2021-10-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.