BACKGROUND: Since a previous meta-analysis reported that ultrasound guidance was associated with a higher first-attempt success rate in catheterization of the radial artery, a number of randomized controlled trials (RCTs) have reported inconsistent results. The aim of the present study is to conduct an updated meta-analysis to clarify the role of ultrasound guidance for radial artery catheterization.Entities:
Mesh:
Year: 2014 PMID: 25375152 PMCID: PMC4222952 DOI: 10.1371/journal.pone.0111527
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1The flow diagram of the selection process of the included studies.
Characteristics of the included studies.
| Study/Year | Country | Population | Patients | Age (y) | Clinical Setting | Operator Experience | Ultrasound Equipment | Ultrasound-guided Approach |
| Levin et al, 2003 | Israel | Adults | 69 | UG: 59.9±14.8 Palpation: 66.4±14.3 | Elective abdominal, cardiothoracic, vascular surgery and neurosurgery in operating room | Anesthetists with experience of ultrasound-guided central venous catheterization but no experience of ultrasound-guided arterial catheterization | 4-MHz transducer of the portable ultrasound device (Site Rite II, Dymax Corporation, Pittsburgh, PA) | short axis out-of-plane |
| Schwemmer et al, 2006 | Germany | Small children and infants | 30 | UG: 3.4±2.9 Palpation: 3.3±2.7 | Elective major neurosurgery in operating room | Anesthetists with experience of >20 ultrasound-guided arterial catheterization | 15-MHz transducer of small parts imaging capability (Sonos 5000; Hewlett-Packard, Andover, MA, USA) | short axis out-of-plane |
| Shiver et al, 2006 | USA | Adults | 60 | ≥18 | Emergency department | Attending physicians with experience of ultrasound-guided peripheral and central venous catheterization but no experience of ultrasound-guided arterial catheterization | SonoSite Ilook 25 (Bothell, WA) US machine with a 5-10 MHz transducer | long axis in-plane |
| Ganesh et al, 2009 | USA | Children | 152 | UG: 8.3±5.8 Palpation: 8.3±6.0 | Elective abdominal, craniofacial, orthopedic, thoracic surgery and neurosurgery in operating room | Anesthetists with experience of <10 ultrasound-guided arterial catheterization | 5–10 MHz transducer of the portable US device (SonoSite 180 plus, SonoSite, Bothell, WA) | short axis out-of-plane |
| Bobbia et al, 2013 | France | Adults | 72 | UG: 69 (56–82) | Emergency department | Physicians receiving 3 hours of simulator training on ultrasound-guided arterial puncture | 10-MHz transducer of GE Vivid S6 machine (General Electric Company, Fairfield, CT) | Not reported |
| Ishii et al, 2013 | Japan | Small children and infants | 59 | 1.5 (0.6–2.3) | Elective cardiac surgery for congenital heart disease in operating room | Anesthetists with experience of ultrasound-guided central venous catheterization but no experience of ultrasound-guided arterial catheterization | 2–7 MHz transducer of SonoSite 180 ultrasound imaging device (SonoSite, Bothell, WA) | short axis out-of-plane |
| Hansen et al, 2014 | Denmark | Adults | 40 | 65.8±16.1 | Elective cardiac surgery in operating room | Anesthetists with 20-year experience in transesophageal and transthoracic ultrasonography, 1-year experience with ultrasonography dynamic needle tip positioning | 18-MHz transducer of a Flex-Focus 400 anesthesia ultrasonography system (BKMedical, Herlev, Denmark) | short axis out-of-plane |
UG = ultrasound guidance.
Median (interquartile range).
Assessing risk of bias.
| Study/Year | Sequence Generation | Allocation Concealment | Blinding | Complete Outcome Data Addressed | No selective Outcome Reporting | Free of Other Bias |
| Levin et al, 2003 | Unclear | Unclear | No | Yes | Yes | Yes |
| Schwemmer et al, 2006 | Yes | Unclear | No | Yes | Yes | Yes |
| Shiver et al, 2006 | Yes | Yes | No | Yes | Yes | Yes |
| Ganesh et al, 2009 | Yes | Unclear | No | Yes | Yes | Yes |
| Bobbia et al, 2013 | Yes | Unclear | No | No | Yes | Yes |
| Ishii et al, 2013 | Unclear | Unclear | No | Yes | Yes | Yes |
| Hansen et al, 2014 | Yes | Unclear | Yes | Yes | Yes | Yes |
Figure 2The forest plot depicting first-attempt success.
Figure 3The forest plot depicting mean-attempts to success.
Figure 4The forest plot depicting mean-time to success.
Figure 5The forest plot depicting the occurrence of hematoma.