Literature DB >> 34624719

An open-source, low-cost NMR spectrometer operating in the mT field regime.

Nicholas Bryden1, Michael Antonacci1, Michele Kelley1, Rosa T Branca2.   

Abstract

In recent years, low field and ultra-low field NMR spectrometers have gained interest due to their portability, lower cost, and reduced subject-induced magnetic field inhomogeneities. Here, we describe the design of a low-cost multinuclear NMR spectrometer operating in the ultra-low field regime (ULF), which possesses high spectral resolution and enables arbitrary pulse programming. An inexpensive multifunction input/output (I/O) device is used to handle waveform generation and digitization in the kHz operating range. A home-built radio frequency (RF) mixing circuit is used to down-mix the NMR signals, allowing for the slower sampling rates and lower memory requirements needed to enable minute-long acquisitions using a standard Windows PC. The LabVIEW code, along with a bill of materials for all components used in the spectrometer, is included. As proof of concept, 1H relaxation measurements and the simultaneous detection of 1H with gas phase and dissolved 129Xe frequencies using the described low field NMR spectrometer are demonstrated.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Hyperpolarized; LabVIEW digital spectrometer; Low-field NMR

Year:  2021        PMID: 34624719      PMCID: PMC9208334          DOI: 10.1016/j.jmr.2021.107076

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.734


  22 in total

1.  Uniform magnetic fields and double-wrapped coil systems: improved techniques for the design of bioelectromagnetic experiments.

Authors:  J L Kirschvink
Journal:  Bioelectromagnetics       Date:  1992       Impact factor: 2.010

2.  A portable Halbach magnet that can be opened and closed without force: the NMR-CUFF.

Authors:  Carel W Windt; Helmut Soltner; Dagmar van Dusschoten; Peter Blümler
Journal:  J Magn Reson       Date:  2010-10-30       Impact factor: 2.229

3.  An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging.

Authors:  L L Tsai; R W Mair; M S Rosen; S Patz; R L Walsworth
Journal:  J Magn Reson       Date:  2008-05-24       Impact factor: 2.229

4.  A readout magnet for prepolarized MRI.

Authors:  P Morgan; S Conolly; G Scott; A Macovski
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

5.  Simultaneous estimation of T₁ and the flip angle in hyperpolarized NMR experiments using acquisition at non-regular time intervals.

Authors:  Max Puckeridge; Guilhem Pagès; Philip W Kuchel
Journal:  J Magn Reson       Date:  2012-06-23       Impact factor: 2.229

6.  Novel approaches to low-cost MRI.

Authors:  A Macovski; S Conolly
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

7.  A Constant-Volume Ventilator and Gas Recapture System for Hyperpolarized Gas MRI of Mouse and Rat Lungs.

Authors:  John Nouls; Manuel Fanarjian; Laurence Hedlund; Bastiaan Driehuys
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-04       Impact factor: 1.176

8.  Xenon NMR: chemical shifts of a general anesthetic in common solvents, proteins, and membranes.

Authors:  K W Miller; N V Reo; A J Schoot Uiterkamp; D P Stengle; T R Stengle; K L Williamson
Journal:  Proc Natl Acad Sci U S A       Date:  1981-08       Impact factor: 11.205

9.  Design of a sustainable prepolarizing magnetic resonance imaging system for infant hydrocephalus.

Authors:  Johnes Obungoloch; Joshua R Harper; Steven Consevage; Igor M Savukov; Thomas Neuberger; Srinivas Tadigadapa; Steven J Schiff
Journal:  MAGMA       Date:  2018-04-11       Impact factor: 2.310

10.  Low-Cost High-Performance MRI.

Authors:  Mathieu Sarracanie; Cristen D LaPierre; Najat Salameh; David E J Waddington; Thomas Witzel; Matthew S Rosen
Journal:  Sci Rep       Date:  2015-10-15       Impact factor: 4.379

View more
  1 in total

1.  Longitudinal nuclear spin relaxation of 129 Xe in solution and in hollow fiber membranes at low and high magnetic field strengths.

Authors:  Nicholas Bryden; Christian T McHugh; Michele Kelley; Rosa T Branca
Journal:  Magn Reson Med       Date:  2022-06-20       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.