Abstract
PURPOSE: To assess the preoperative objective angle alpha and angle kappa measurements of patients deciding to undergo multifocal refractive lens surgery based on a subjective positive multifocal contact lens test (MCLT).Entities:
Keywords: Angle alpha; Angle kappa; Decision-making; Multifocal intraocular lens; Refractive lens surgery
Mesh:
Year: 2021 PMID: 34581851 PMCID: PMC8786761 DOI: 10.1007/s00417-021-05403-w
Source DB: PubMed Journal: Graefes Arch Clin Exp Ophthalmol ISSN: 0721-832X Impact factor: 3.117
Preoperative patient parameters in both group of patients (contact lens test positive and contact lens negative)
| §§ | Positive contact lens test ( | Negative contact lens test ( | |
|---|---|---|---|
| Parameter | Mean ± SD | Mean ± SD | |
| UDVA (logMAR) | 0.69 (0.50) | 0.56 (0.46) | 0.046 |
| CDVA (logMAR) | −0.08 (0.08) | −0.11 (0.10) | 0.084 |
| CLDVA (logMAR) | 0.03 (0.09) | 0.03 (0.13) | 0.878 |
| Spherical equivalent (D) | 1.05 (4.07) | 0.24 (3.02) | 0.103 |
| Angle alpha (mm) | 0.50 (0.18) | 0.49 (0.16) | 0.662 |
| Angle kappa (mm) | 0.36 (0.16) | 0.38 (0.16) | 0.349 |
| Higher order aberrations (mm) | 0.12 (0.09) | 0.14 (0.07) | 0.309 |
| Dysfunctional lens index (DLI) | 7.87 (2.01) | 8.60 (1.72) | 0.012 |
| IOL power (D)* | 22.31 (5.11) | n.a. | n.a. |
*All patients with a positive contact lens test underwent refractive lens surgery
UCVA uncorrected distance visual acuity, CDVA corrected distance visual acuity, CLDVA contact lens corrected distance visual acuity, IOL intraocular lens, n.a. not applicable
Distribution of angle alpha and angle kappa measurement in both group of patients (surgery vs no surgery)
| No surgery ( | Surgery* ( | # Eyes with ideal alpha and kappa angles | ||||||
|---|---|---|---|---|---|---|---|---|
| Angle alpha | ||||||||
| <0.5 | ≥0.5 | <0.5 | ≥0.5 | |||||
| <0.5 | #(%) | 71 (49) | 50 (34) | 35 (49) | 24 (34) | 106 (49) | ||
| Angle kappa | ||||||||
| ≥0.5 | #(%) | 3 (2) | 22 (15) | - | 12 (17) | |||
*All patients with positive contact lens test underwent surgery
# = number
Fig. 1Scatter plot showing the correlation between angle kappa values and spherical equivalent stratified for eyes undergoing IOL surgery (green dots) vs. no surgery eyes (red dots). Lines represent non-linear relationship between plotted variables using local polynomial smoothing
Fig. 2Shows the relationship between spherical equivalent and angle kappa values of this study and the published literature (Basmak 2017, Reference 18 of this article). For the purpose of comparability, mean spherical equivalent values were calculated for intervals used by Basmak et al. and the kappa values of this study were transformed