Electrochemiluminescence biosensor based on molybdenum disulfide-graphene quantum dots nanocomposites and DNA walker signal amplification for DNA detection.

Yina Sun1, Chuan Huang1, Xiujin Sun2, Qian Wang1,3, Peini Zhao4, Shenguang Ge5, Jinghua Yu3.   

Abstract

Based on the prominent electrochemiluminescence (ECL) performances of molybdenum disulfide-graphene quantum dots (MoS2-GQDs) nanocomposite and combined with enzyme-assisted recycling DNA walker signal amplification, an "on-off" switch ECL biosensor was proposed for sensitive assay of specific DNA sequences. Noticeably, MoS2 with two-dimensional nanosheet structure increased the loading capacity of GQDs to support abundant hairpin DNA (H). The composites of MoS2 and GQDs facilitated the charge transfer in ECL process, which significantly improved the ECL signal to achieve an "on" state. Then, the DNA walker cyclic amplification was performed by adding the target DNA and exonuclease III (Exo III). Finally, the DNA2-Fc-DNA1 was introduced into the system as ECL signal quencher, turning the ECL signal into an "off" state. The sensitive assay of ultra-low concentration specific DNA sequences was realized according to the variation of ECL signal strength before and after the existence of target DNA. The proposed ECL biosensor showed a good linear relationship ranging from 1 nM to 100 aM with a detection limit of 25.1 aM, providing a powerful strategy for biomedical research and clinical analysis.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.

Entities:  

Keywords:  DNA walker; Electrochemiluminescence biosensors; Molybdenum disulfide-graphene quantum dots; Signal amplification

Mesh:

Year:  2021        PMID: 34568991     DOI: 10.1007/s00604-021-04962-3

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  25 in total

1.  Highly sensitive electrochemical biosensor based on nonlinear hybridization chain reaction for DNA detection.

Authors:  Liping Jia; Shanshan Shi; Rongna Ma; Wenli Jia; Huaisheng Wang
Journal:  Biosens Bioelectron       Date:  2016-02-03       Impact factor: 10.618

Review 2.  Recent progress on DNA based walkers.

Authors:  Jing Pan; Feiran Li; Tae-Gon Cha; Haorong Chen; Jong Hyun Choi
Journal:  Curr Opin Biotechnol       Date:  2014-12-08       Impact factor: 9.740

3.  Hairpin assembly-triggered cyclic activation of a DNA machine for label-free and ultrasensitive chemiluminescence detection of DNA.

Authors:  Jia Chen; Hongdeng Qiu; Mingliang Zhang; Tongnian Gu; Shijun Shao; Yong Huang; Shulin Zhao
Journal:  Biosens Bioelectron       Date:  2015-01-23       Impact factor: 10.618

4.  TiO2 nanowires as an effective sensing platform for rapid fluorescence detection of single-stranded DNA and double-stranded DNA.

Authors:  Wei Ding; Chan Song; Tianle Li; Haoran Ma; Yuewei Yao; Cheng Yao
Journal:  Talanta       Date:  2019-02-02       Impact factor: 6.057

5.  A multiplex and regenerable surface plasmon resonance (MR-SPR) biosensor for DNA detection of genetically modified organisms.

Authors:  Na An; Kai Li; Yukun Zhang; Tingting Wen; Weixiao Liu; Gang Liu; Liang Li; Wujun Jin
Journal:  Talanta       Date:  2021-03-31       Impact factor: 6.057

6.  A highly integrated real-time digital PCR device for accurate DNA quantitative analysis.

Authors:  Shufang Zhou; Tong Gou; Jiumei Hu; Wenshuai Wu; Xiong Ding; Weibo Fang; Zhenming Hu; Ying Mu
Journal:  Biosens Bioelectron       Date:  2019-01-11       Impact factor: 10.618

7.  Rolling circle amplification combined with gold nanoparticles-tag for ultra sensitive and specific quantification of DNA by inductively coupled plasma mass spectrometry.

Authors:  Ye He; Danlong Chen; Mengxue Li; Ling Fang; WeiJuan Yang; LiangJun Xu; FengFu Fu
Journal:  Biosens Bioelectron       Date:  2014-03-06       Impact factor: 10.618

8.  Ultrasensitive electrochemical biosensor for specific detection of DNA based on molecular beacon mediated circular strand displacement polymerization and hyperbranched rolling circle amplification.

Authors:  Xiaolu Li; Jing Guo; Qian Zhai; Jing Xia; Gang Yi
Journal:  Anal Chim Acta       Date:  2016-06-22       Impact factor: 6.558

9.  Ultrasensitive Electrochemical DNA Biosensor Based on a Label-Free Assembling Strategy Using a Triblock polyA DNA Probe.

Authors:  Lele Wang; Yanli Wen; Xue Yang; Li Xu; Wen Liang; Ying Zhu; Lihua Wang; Yan Li; Yuan Li; Min Ding; Shuzhen Ren; Zhenzhou Yang; Min Lv; Jichao Zhang; Kang Ma; Gang Liu
Journal:  Anal Chem       Date:  2019-12-05       Impact factor: 6.986

10.  Enrichment-Stowage-Cycle Strategy for Ultrasensitive Electrochemiluminescent Detection of HIV-DNA with Wide Dynamic Range.

Authors:  Zhen Wu; Fanwei Luo; Wei Wen; Xiuhua Zhang; Shengfu Wang
Journal:  Anal Chem       Date:  2019-09-12       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.