A highly integrated real-time digital PCR device for accurate DNA quantitative analysis.

Shufang Zhou1, Tong Gou1, Jiumei Hu2, Wenshuai Wu2, Xiong Ding2, Weibo Fang1, Zhenming Hu1, Ying Mu3.   

Abstract

Misclassification of positive partitions in microfluidic digital polymerase chain reaction (dPCR) can cause the false positives and false negatives, which significantly alter the resulting estimate of target DNA molecules. To address this issue, establishing real-time fluorescence interrogation of each partition in microfluidic arrays is an effective way in which false positive and false negative partitions can be eliminated. However, currently available devices for real-time fluorescence interrogation are either not competent for microfluidic digital array, or they are bulky, expensive and entail peripheral equipment due to low integration. Therefore, in this study, a Raspberry Pi based, low-cost and highly integrated device is presented to achieve real-time fluorescence detection for microfluidic digital array, termed real-time dPCR device. In the device, uniform thermocycler, streamlined real-time fluorescence imaging setup, and compact data processing system are all integrated to undergo on-chip dPCR amplification, real-time fluorescence detection, and data analysis. Using this real-time dPCR device, the accuracy of DNA absolute quantification by dPCR is improved, since the misclassification of positive partitions is efficiently reduced based on the characteristic real-time fluorescence curves of positive partitions in a self-priming microfluidic chip. Compared with end-point dPCR on our device and commercialized QuantStudio™ 3D dPCR system, the real-time dPCR on our device exhibits a higher accuracy for DNA quantification. In addition, this real-time dPCR device is much smaller and cheaper than the commercialized Digital PCR system, but not sacrificing the capability of error correction for absolute quantitation analysis. Conclusively, this highly integrated real-time dPCR device is very beneficial for DNA quantitative analysis where the determination accuracy is pivotal.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  Absolute quantitative accuracy; Microfluidic chip; Raspberry Pi; Real-time digital PCR

Mesh:

Substances:

Year:  2019        PMID: 30660930     DOI: 10.1016/j.bios.2018.12.055

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

Review 1.  Nucleic Acids Analysis.

Authors:  Yongxi Zhao; Xiaolei Zuo; Qian Li; Feng Chen; Yan-Ru Chen; Jinqi Deng; Da Han; Changlong Hao; Fujian Huang; Yanyi Huang; Guoliang Ke; Hua Kuang; Fan Li; Jiang Li; Min Li; Na Li; Zhenyu Lin; Dingbin Liu; Juewen Liu; Libing Liu; Xiaoguo Liu; Chunhua Lu; Fang Luo; Xiuhai Mao; Jiashu Sun; Bo Tang; Fei Wang; Jianbin Wang; Lihua Wang; Shu Wang; Lingling Wu; Zai-Sheng Wu; Fan Xia; Chuanlai Xu; Yang Yang; Bi-Feng Yuan; Quan Yuan; Chao Zhang; Zhi Zhu; Chaoyong Yang; Xiao-Bing Zhang; Huanghao Yang; Weihong Tan; Chunhai Fan
Journal:  Sci China Chem       Date:  2020-12-02       Impact factor: 9.445

2.  Conductive Silver/Carbon Fiber Films for Rapid Detection of Human Coronavirus.

Authors:  Hwan Gyun Jeon; Ji Wook Choi; Hee Uk Lee; Bong Geun Chung
Journal:  Polymers (Basel)       Date:  2022-05-12       Impact factor: 4.967

3.  Development of Low-Cost Point-of-Care Technologies for Cervical Cancer Prevention Based on a Single-Board Computer.

Authors:  Sonia Parra; Eduardo Carranza; Jackson Coole; Brady Hunt; Chelsey Smith; Pelham Keahey; Mauricio Maza; Kathleen Schmeler; Rebecca Richards-Kortum
Journal:  IEEE J Transl Eng Health Med       Date:  2020-02-03       Impact factor: 3.316

4.  Electrochemiluminescence biosensor based on molybdenum disulfide-graphene quantum dots nanocomposites and DNA walker signal amplification for DNA detection.

Authors:  Yina Sun; Chuan Huang; Xiujin Sun; Qian Wang; Peini Zhao; Shenguang Ge; Jinghua Yu
Journal:  Mikrochim Acta       Date:  2021-09-26       Impact factor: 5.833

5.  The Incorporation of Amplified Metal-Enhanced Fluorescence in a CMOS-Based Biosensor Increased the Detection Sensitivity of a DNA Marker of the Pathogenic Fungus Colletotrichum gloeosporioides.

Authors:  Dorin Harpaz; Noam Alkan; Evgeni Eltzov
Journal:  Biosensors (Basel)       Date:  2020-12-13

6.  A Double-Deck Self-Digitization Microfluidic Chip for Digital PCR.

Authors:  Gangwei Xu; Huaqing Si; Fengxiang Jing; Peng Sun; Dan Zhao; Dongping Wu
Journal:  Micromachines (Basel)       Date:  2020-11-24       Impact factor: 2.891

Review 7.  Digital PCR Applications in the SARS-CoV-2/COVID-19 Era: a Roadmap for Future Outbreaks.

Authors:  Raphael Nyaruaba; Caroline Mwaliko; David Dobnik; Pavel Neužil; Patrick Amoth; Matilu Mwau; Junping Yu; Hang Yang; Hongping Wei
Journal:  Clin Microbiol Rev       Date:  2022-03-08       Impact factor: 50.129

8.  An Integrated Smartphone-Based Genetic Analyzer for Qualitative and Quantitative Pathogen Detection.

Authors:  Hau Van Nguyen; Van Dan Nguyen; Fei Liu; Tae Seok Seo
Journal:  ACS Omega       Date:  2020-07-27

9.  Sensing Optimum in the Raw: Leveraging the Raw-Data Imaging Capabilities of Raspberry Pi for Diagnostics Applications.

Authors:  Alessandro Tonelli; Veronica Mangia; Alessandro Candiani; Francesco Pasquali; Tiziana Jessica Mangiaracina; Alessandro Grazioli; Michele Sozzi; Davide Gorni; Simona Bussolati; Annamaria Cucinotta; Giuseppina Basini; Stefano Selleri
Journal:  Sensors (Basel)       Date:  2021-05-20       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.