The effect of central corneal thickness on Goldmann tonometry: a retrospective study.

Tal Yahalomi1, Natalya Kovalyuk2, Roee Arnon2, Barak Hen2, Joseph Pikkel2.   

Abstract

PURPOSE: To determine the relation between central corneal thickness and intraocular pressure. PATIENTS AND METHODS: This retrospective study investigated 112 eyes from 56 individuals who underwent photorefractive keratectomy in a single private medical center between May 2018 and September 2019. Intraocular pressure readings were obtained with Goldmann applanation tonometry, and central corneal thickness measurements were evaluated preoperatively. All the examinations were repeated at 3 and 6 months postoperative.
RESULTS: At 3 and 6 months postoperative, the mean intraocular pressure was only slightly reduced from baseline (mean reduction of 0.6 ± 2.0 mmHg, P < 0.001 and 0.73 ± 2.14 mmHg, P < 0.001, respectively). The change in intraocular pressure following photorefractive keratectomy was not clinically significant, and this change was not correlated with postoperative central corneal thickness at 3 months (p = 0.620, r = 0.047).
CONCLUSION: This study showed that the change in intraocular pressure following photorefractive keratectomy was not clinically significant, and ruled out a correlation in this context between the change in central corneal thickness and the delta intraocular pressure. Our results might question the axiom between central corneal thickness and intraocular pressure and may thus challenge the current clinical setting for evaluating glaucoma.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Central corneal thickness; Goldmann applanation tonometry; Intraocular pressure; Photorefractive keratectomy

Mesh:

Year:  2021        PMID: 34554360     DOI: 10.1007/s10792-021-02021-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  10 in total

1.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

2.  Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry.

Authors:  Fatih Özcura; Sayime Aydın; Nevin Uzgören
Journal:  Jpn J Ophthalmol       Date:  2008-11-11       Impact factor: 2.447

3.  Goldmann applanation tonometry after myopic photorefractive keratectomy.

Authors:  N Rosa; G Cennamo; M A Breve; A La Rana
Journal:  Acta Ophthalmol Scand       Date:  1998-10

4.  Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy.

Authors:  O E Abbasoglu; R W Bowman; H D Cavanagh; J P McCulley
Journal:  Ophthalmology       Date:  1998-12       Impact factor: 12.079

5.  Change in intraocular pressure measurement after myopic LASEK: a study evaluating goldmann, pascal and applanation resonance tonometry.

Authors:  Gauti Jóhannesson; Per Hallberg; Anders Eklund; Timo Koskela; Christina Lindén
Journal:  J Glaucoma       Date:  2012 Apr-May       Impact factor: 2.503

6.  [How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?].

Authors:  T Schwenteck; M Knappe; I Moros
Journal:  Klin Monbl Augenheilkd       Date:  2012-09-12       Impact factor: 0.700

7.  Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

Authors:  Shirin Hamed-Azzam; Daniel Briscoe; Oren Tomkins; Raneen Shehedeh-Mashor; Hanna Garzozi
Journal:  Int Ophthalmol       Date:  2012-12-29       Impact factor: 2.031

8.  Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure.

Authors:  Aimee Teo Broman; Nathan G Congdon; Karen Bandeen-Roche; Harry A Quigley
Journal:  J Glaucoma       Date:  2007 Oct-Nov       Impact factor: 2.503

9.  Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery.

Authors:  Shireen Ma Shousha; Mahmoud Ah Abo Steit; Mohamed Hm Hosny; Wael A Ewais; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-01-08

10.  Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK.

Authors:  Gabi Shemesh; Uri Soiberman; Shimon Kurtz
Journal:  Clin Ophthalmol       Date:  2012-11-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.