PURPOSE: Low-rank denoising of MRSI data results in an apparent increase in spectral SNR. However, it is not clear if this translates to a lower uncertainty in metabolite concentrations after spectroscopic fitting. Estimation of the true uncertainty after denoising is desirable for downstream analysis in spectroscopy. In this work, the uncertainty reduction from low-rank denoising methods based on spatiotemporal separability and linear predictability in MRSI are assessed. A new method for estimating metabolite concentration uncertainty after denoising is proposed. Automatic rank threshold selection methods are also assessed in simulated low SNR regimes.
METHODS: Assessment of denoising methods is conducted using Monte Carlo simulation of proton MRSI data and by reproducibility of repeated in vivo acquisitions in 5 subjects.
RESULTS: In simulated and in vivo data, spatiotemporal based denoising is shown to reduce the concentration uncertainty, but linear prediction denoising increases uncertainty. Uncertainty estimates provided by fitting algorithms after denoising consistently underestimate actual metabolite uncertainty. However, the proposed uncertainty estimation, based on an analytical expression for entry-wise variance after denoising, is more accurate. It is also shown automated rank threshold selection using Marchenko-Pastur distribution can bias the data in low SNR conditions. An alternative soft-thresholding function is proposed.
CONCLUSION: Low-rank denoising methods based on spatiotemporal separability do reduce uncertainty in MRS(I) data. However, thorough assessment is needed as assessment by SNR measured from residual baseline noise is insufficient given the presence of non-uniform variance. It is also important to select the right rank thresholding method in low SNR cases.
© 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRS; MRSI; denoising; low rank; spectroscopy

Mesh:

Year:  2021        PMID: 34545962      PMCID: PMC7612041          DOI: 10.1002/mrm.29018

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  17 in total

1.  Measurement and correction of respiration-induced B0 variations in breast 1H MRS at 4 Tesla.

Authors:  Patrick J Bolan; Pierre-Gilles Henry; Eva H Baker; Sina Meisamy; Michael Garwood
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

2.  Denoising of diffusion MRI using random matrix theory.

Authors:  Jelle Veraart; Dmitry S Novikov; Daan Christiaens; Benjamin Ades-Aron; Jan Sijbers; Els Fieremans
Journal:  Neuroimage       Date:  2016-08-11       Impact factor: 6.556

3.  PCA denoising and Wiener deconvolution of 31 P 3D CSI data to enhance effective SNR and improve point spread function.

Authors:  Martijn Froeling; Jeanine J Prompers; Dennis W J Klomp; Tijl A van der Velden
Journal:  Magn Reson Med       Date:  2021-02-01       Impact factor: 4.668

4.  Coil combination for receive array spectroscopy: Are data-driven methods superior to methods using computed field maps?

Authors:  Christopher T Rodgers; Matthew D Robson
Journal:  Magn Reson Med       Date:  2015-03-28       Impact factor: 4.668

5.  Density-weighted concentric rings k-space trajectory for 1 H magnetic resonance spectroscopic imaging at 7 T.

Authors:  Mark Chiew; Wenwen Jiang; Brian Burns; Peder Larson; Adam Steel; Peter Jezzard; M Albert Thomas; Uzay E Emir
Journal:  NMR Biomed       Date:  2017-10-18       Impact factor: 4.044

6.  Inference and uncertainty quantification for noisy matrix completion.

Authors:  Yuxin Chen; Jianqing Fan; Cong Ma; Yuling Yan
Journal:  Proc Natl Acad Sci U S A       Date:  2019-10-30       Impact factor: 11.205

7.  NOise reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing.

Authors:  Steen Moeller; Pramod Kumar Pisharady; Sudhir Ramanna; Christophe Lenglet; Xiaoping Wu; Logan Dowdle; Essa Yacoub; Kamil Uğurbil; Mehmet Akçakaya
Journal:  Neuroimage       Date:  2020-11-10       Impact factor: 6.556

8.  Application of low-rank approximation using truncated singular value decomposition for noise reduction in hyperpolarized 13 C NMR spectroscopy.

Authors:  R Francischello; M Geppi; A Flori; E M Vasini; S Sykora; L Menichetti
Journal:  NMR Biomed       Date:  2020-03-03       Impact factor: 4.044

9.  Dynamic Imaging of Glucose and Lactate Metabolism by 13C-MRS without Hyperpolarization.

Authors:  Jeffrey R Brender; Shun Kishimoto; Hellmut Merkle; Galen Reed; Ralph E Hurd; Albert P Chen; Jan Henrik Ardenkjaer-Larsen; Jeeva Munasinghe; Keita Saito; Tomohiro Seki; Nobu Oshima; Kazutoshi Yamamoto; Peter L Choyke; James Mitchell; Murali C Krishna
Journal:  Sci Rep       Date:  2019-03-04       Impact factor: 4.379

10.  FSL-MRS: An end-to-end spectroscopy analysis package.

Authors:  William T Clarke; Charlotte J Stagg; Saad Jbabdi
Journal:  Magn Reson Med       Date:  2020-12-06       Impact factor: 3.737

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.