Literature DB >> 34542196

Quantitative effects of off-resonance related distortion on brain mechanical property estimation with magnetic resonance elastography.

Grace McIlvain1, Matthew D J McGarry2, Curtis L Johnson1.   

Abstract

Off-resonance related geometric distortion can impact quantitative MRI techniques, such as magnetic resonance elastography (MRE), and result in errors to these otherwise sensitive metrics of brain health. MRE is a phase contrast technique to determine the mechanical properties of tissue by imaging shear wave displacements and estimating tissue stiffness through inverse solution of Navier's equation. In this study, we systematically examined the quantitative effects of distortion and corresponding correction approaches on MRE measurements through a series of simulations, phantom models, and in vivo brain experiments. We studied two different k-space trajectories, echo-planar imaging and spiral, and we determined that readout time, off-resonance gradient strength, and the combination of readout direction and off-resonance gradient direction, impact the estimated mechanical properties. Images were also processed through traditional distortion correction pipelines, and we found that each of the correction mechanisms works well for reducing stiffness errors, but are limited in cases of very large distortion. The ability of MRE to detect subtle changes to neural tissue health relies on accurate, artifact-free imaging, and thus off-resonance related geometric distortion must be considered when designing sequences and protocols by limiting readout time and applying correction where appropriate.
© 2021 John Wiley & Sons, Ltd.

Entities:  

Keywords:  brain; distortion; magnetic resonance elastography; off-resonance; viscoelasticity

Mesh:

Year:  2021        PMID: 34542196      PMCID: PMC8688217          DOI: 10.1002/nbm.4616

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  60 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Advances in sensitivity encoding with arbitrary k-space trajectories.

Authors:  K P Pruessmann; M Weiger; P Börnert; P Boesiger
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

Review 3.  Spiral imaging: a critical appraisal.

Authors:  Kai Tobias Block; Jens Frahm
Journal:  J Magn Reson Imaging       Date:  2005-06       Impact factor: 4.813

4.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

5.  Distortion correction for diffusion-weighted MRI tractography and fMRI in the temporal lobes.

Authors:  Karl V Embleton; Hamied A Haroon; David M Morris; Matthew A Lambon Ralph; Geoff J M Parker
Journal:  Hum Brain Mapp       Date:  2010-10       Impact factor: 5.038

6.  Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps.

Authors:  P J Reber; E C Wong; R B Buxton; L R Frank
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

7.  Intravoxel B0 inhomogeneity corrected reconstruction using a low-rank encoding operator.

Authors:  Fan Lam; Bradley P Sutton
Journal:  Magn Reson Med       Date:  2020-02-05       Impact factor: 4.668

8.  Analysis and correction of off-resonance artifacts in echo-planar cardiac diffusion tensor imaging.

Authors:  Robbert J H van Gorkum; Constantin von Deuster; Christian Guenthner; Christian T Stoeck; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2020-06-12       Impact factor: 4.668

9.  An octahedral shear strain-based measure of SNR for 3D MR elastography.

Authors:  M D J McGarry; E E W Van Houten; P R Perriñez; A J Pattison; J B Weaver; K D Paulsen
Journal:  Phys Med Biol       Date:  2011-06-08       Impact factor: 3.609

10.  The influence of physiological aging and atrophy on brain viscoelastic properties in humans.

Authors:  Ingolf Sack; Kaspar-Josche Streitberger; Dagmar Krefting; Friedemann Paul; Jürgen Braun
Journal:  PLoS One       Date:  2011-09-12       Impact factor: 3.240

View more
  3 in total

1.  Correlated noise in brain magnetic resonance elastography.

Authors:  Ariel J Hannum; Grace McIlvain; Damian Sowinski; Matthew D J McGarry; Curtis L Johnson
Journal:  Magn Reson Med       Date:  2021-10-22       Impact factor: 4.668

2.  OSCILLATE: A low-rank approach for accelerated magnetic resonance elastography.

Authors:  Grace McIlvain; Alexander M Cerjanic; Anthony G Christodoulou; Matthew D J McGarry; Curtis L Johnson
Journal:  Magn Reson Med       Date:  2022-06-01       Impact factor: 3.737

3.  Evaluation of cerebral cortex viscoelastic property estimation with nonlinear inversion magnetic resonance elastography.

Authors:  Lucy V Hiscox; Matthew D J McGarry; Curtis L Johnson
Journal:  Phys Med Biol       Date:  2022-04-15       Impact factor: 4.174

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.