Literature DB >> 34529736

WHotLAMP: A simple, inexpensive, and sensitive molecular test for the detection of SARS-CoV-2 in saliva.

David Ng1, Ana Pinharanda2, Merly C Vogt2,3, Ashok Litwin-Kumar1, Kyle Stearns4, Urvashi Thopte1, Enrico Cannavo1, Armen Enikolopov5, Felix Fiederling1, Stylianos Kosmidis1, Barbara Noro1, Ines Rodrigues-Vaz1, Hani Shayya1, Peter Andolfatto2, Darcy S Peterka1, Tanya Tabachnik1, Jeanine D'Armiento4,6, Monica Goldklang4,6, Andres Bendesky1,7.   

Abstract

Despite the development of effective vaccines against SARS-CoV-2, epidemiological control of the virus is still challenging due to slow vaccine rollouts, incomplete vaccine protection to current and emerging variants, and unwillingness to get vaccinated. Therefore, frequent testing of individuals to identify early SARS-CoV-2 infections, contact-tracing and isolation strategies remain crucial to mitigate viral spread. Here, we describe WHotLAMP, a rapid molecular test to detect SARS-CoV-2 in saliva. WHotLAMP is simple to use, highly sensitive (~4 viral particles per microliter of saliva) and specific, as well as inexpensive, making it ideal for frequent screening. Moreover, WHotLAMP does not require toxic chemicals or specialized equipment and thus can be performed in point-of-care settings, and may also be adapted for resource-limited environments or home use. While applied here to SARS-CoV-2, WHotLAMP can be modified to detect other pathogens, making it adaptable for other diagnostic assays, including for use in future outbreaks.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34529736      PMCID: PMC8445428          DOI: 10.1371/journal.pone.0257464

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.752


Introduction

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a novel coronavirus with high transmissibility that causes the Coronavirus Disease of 2019 (COVID-19) [1, 2]. Unlike SARS-CoV-1, where infectiousness is mostly restricted to the symptomatic phase [3], ~50% of SARS-CoV-2 transmissions occur 1–2 days before symptom onset or through people who never develop symptoms [4-6]. Thus, screening for symptoms is not enough to stop SARS-CoV-2 transmission [7]. Testing, combined with contact tracing and social isolation, along with physical barriers such as face masks and distancing, became staple strategies to reduce community spread [8]. However, in many countries, viral spread has been difficult to contain. This is partly due to insufficient testing infrastructure, which leads to long delays in both access to testing and in obtaining test results. This lag greatly reduces the effectiveness of contact-tracing and isolation strategies [9, 10]. Despite the development of safe and effective vaccines against SARS-CoV-2, the threat of the virus remains high because of the logistical difficulties of global vaccination, limited supply of vaccine doses, and reluctance to get vaccinated [11]. Moreover, the emergence of SARS-CoV-2 variants that lower the protection conferred by natural or vaccine-induced immunity, suggests that testing will remain an important tool to reduce viral transmission [12-14]. Furthermore, without global vaccination coverage there is potential for future viral outbreaks. Frequent testing using ‘rapid’ tests has been proposed as an effective strategy to survey the population and identify infectious people [9, 10], permitting a faster and safer return to prepandemic social and economic activities. A frequent testing strategy is effective if a test is: 1) rapid; 2) inexpensive; 3) simple to use (ideally self-administered for convenience and to minimize health-care resources); 4) sensitive enough to identify most infectious people; and 5) highly specific, so that when prevalence is low, most positives tests are true. Initial tests to detect SARS-CoV-2 infection used deep nasopharyngeal swabs followed by RT-qPCR and were conducted by specially trained personnel [15, 16]. To increase testing capacity and reduce time to get a test result, point-of-care (POC) and home-based diagnosis using ‘rapid’ tests were developed to detect viral antigens from shallow nasal swabs [17]. While these tests provide quick results, even the most sensitive of antigen tests can only detect ~20,000 viral E gene RNA copies per microliter (μL) [18] and may miss up to 30% of people with the high viral loads associated with infectivity [18-28]. Other molecular ‘rapid’ tests detect viral RNA using an isothermal enzymatic reaction to exponentially amplify fragments of the genome [29-34], and some have been approved for emergency use for POC and at home [35, 36]. While this type of rapid test is sensitive, they are expensive and/or require specialized equipment (i.e. are not simple to use). Saliva offers several advantages over nasal and nasopharyngeal swabs for the early detection of SARS-CoV-2 infections: it 1) has a higher viral load than swabs early in an infection [37, 38]; 2) is easier than swabs to obtain from children, who are often anxious about the swabbing procedure; 3) requires fewer materials to collect, diminishing waste and reliance on resources that can be scarce. Several protocols to detect SARS-CoV-2 from saliva have been described [28, 39]. However, these approaches require toxic chemicals or specialized equipment (e.g. centrifuges, pipettes, thermocyclers) which make them impractical for POC, home testing, and other resource-limited environments. Given these considerations, a fast, economical, easy to use test that is both sensitive, specific, and safe, is still required. To this end, we devised WHotLAMP, a rapid molecular test to detect SARS-CoV-2 viral RNA directly from saliva without the need for specialized equipment, with results obtained in 30 minutes. This test extracts RNA from saliva and uses an isothermal enzymatic reaction to amplify and colorimetrically detect SARS-CoV-2 RNA. WHotLAMP is inexpensive, highly sensitive and specific, making it ideal for frequent screening and detection of infectious individuals to limit the spread of SARS-CoV-2.

Results and discussion

A one-tube saliva test to detect SARS-CoV-2 RNA

To develop a simple procedure to extract SARS-CoV-2 RNA from saliva, we leveraged the nucleic acid binding properties of cellulose paper (e.g. Whatman filter paper [40]), and molecular detection of SARS-CoV-2 RNA using loop-mediated isothermal amplification (LAMP), an enzymatic reaction that exponentially amplifies a target nucleic acid sequence at a constant temperature [41]. Inspired by work from Liu et al. [42], we sought to develop an inexpensive, sensitive and simplified test that did not require potentially dangerous chemicals, and would be suitable for frequent use at POC and adaptable for home use. We initially tested saliva spiked with naked SARS-CoV-2 control RNA and found that a short exposure of Whatman No. 1 filter paper to saliva, followed by brief washes, could capture sufficient SARS-CoV-2 control RNA to be detected in a LAMP reaction with primers directed against SARS-CoV-2 (Fig 1A). Amplification of the target sequence leads to a drop in pH, which is detected with a pH-sensitive dye as a color change from pink (negative) to yellow (positive) [32]. We next tested whether we could capture encapsulated SARS-CoV-2 RNA particles that were spiked into saliva, using Whatman paper and an established lysis buffer [40]. This procedure can detect as few as ~4 SARS-CoV-2 particles per μL of saliva (Fig 1B). This level of sensitivity is notable, as it has been determined that 90% of COVID-19 patients carry more than 5 copies of SARS-CoV-2 per μL of saliva [28, 38]. These findings suggest that a strategy using Whatman paper is a viable approach for isolating RNA from SARS-CoV-2 virions in saliva.
Fig 1

Loop-mediated isothermal amplification (LAMP) detection of SARS-CoV-2 RNA captured from saliva using Whatman no. 1 filter.

A. Detection of naked SARS-CoV-2 RNA in saliva. Saliva with spike-in SARS-CoV-2 RNA (tubes 1–3), saliva without RNA spike-in (tubes 4–6), SARS-CoV-2 RNA added directly to LAMP reaction (tube 7), no template control (tube 8). B. Detection of encapsulated SARS-CoV-2 RNA particles in saliva (tubes 1–4); saliva with spike-in encapsulated RNase P RNA particles (tube 5); saliva with spike-in encapsulated SARS-CoV-2 RNA particles with no extraction treatment (tube 6), saliva alone with no spike-in (tube 7), and no saliva (tube 8). LAMP reactions used N2+E1 primers for detection of SARS-CoV-2 RNA. Concentrations are in copies per microliter of saliva.

Loop-mediated isothermal amplification (LAMP) detection of SARS-CoV-2 RNA captured from saliva using Whatman no. 1 filter.

A. Detection of naked SARS-CoV-2 RNA in saliva. Saliva with spike-in SARS-CoV-2 RNA (tubes 1–3), saliva without RNA spike-in (tubes 4–6), SARS-CoV-2 RNA added directly to LAMP reaction (tube 7), no template control (tube 8). B. Detection of encapsulated SARS-CoV-2 RNA particles in saliva (tubes 1–4); saliva with spike-in encapsulated RNase P RNA particles (tube 5); saliva with spike-in encapsulated SARS-CoV-2 RNA particles with no extraction treatment (tube 6), saliva alone with no spike-in (tube 7), and no saliva (tube 8). LAMP reactions used N2+E1 primers for detection of SARS-CoV-2 RNA. Concentrations are in copies per microliter of saliva. Since the original extraction procedure used guanidine hydrochloride (a toxic protein denaturant), we sought an alternative that avoided toxic chemical components. We developed a saliva extraction procedure using only two components, a non-toxic RNA preservative (RNAlater™), and an endopeptidase, Proteinase K. To minimize handling of Whatman paper, we secured a piece of Whatman paper to the bottom of a 1.7 mL centrifuge tube using a small amount of Kwik-Sil™ silicone adhesive. Notably, Kwik-Sil™ did not interfere with the colorimetric pH indicator in the LAMP reaction mixture, whereas other adhesives we examined caused a color change in negative-control reactions without RNA (Table 1).
Table 1

Compatibility of materials with colorimetric LAMP.

CompoundColor change in LAMP (from pink)
Kwik-Sil™ silicone elastomer (World Precision Instruments)N
Clear aquarium silicone (Aqueon)Y
Neutral cure silicone (Dow Corning 737)Y
Ultra-clear polyester plastic sheet (dipstick)N
Glue stick (polyamide, Power Adhesives TEC Bond 7718)Y
Glue stick (acrylic, Infinity Bond)Y
Glue stick (high temperature, Allary)Y
Gorilla glue (original, polyurethane)Y
Crazy Glue (Loctite)Y
Scotch permanent double-sided tapeY
Rubber cement (Best-Test paper cement)Y
WHotLAMP can be performed entirely in a single 1.7 mL microfuge tube (Fig 2A). In this test, viral RNA is preserved using a non-hazardous RNA stabilizing solution and is extracted by a brief Proteinase K digestion. Heating the sample at 95 oC inactivates both Proteinase K and SARS-CoV-2 virions [43], thereby increasing the biosafety of the sample. It was critical to include a wash step to remove both RNAlater solution and saliva that were soaked up by the filter paper, as well as particulates bound to the filter paper. We designed LAMP primer sets throughout the SARS-CoV-2 genome (see Methods), and focused on the primer set (ZI-1, targeting ORF 1a) with the lowest predicted propensity for primer-dimer formation and that avoids known mutations among common SARS-CoV-2 variants that could affect primer binding specificity (Fig 2B and S1 Table for a list of SARS-CoV-2 mutations; covariants.org as of Aug 9, 2021]). To evaluate the specificity of the ZI-1 primers, we tested a panel of 22 inactivated respiratory pathogens, including SARS-CoV-1, MERS, H1N1 influenza, and common respiratory coronaviruses. We detected SARS-CoV-2 RNA in samples containing encapsulated SARS-CoV-2 RNA particles, but not in samples containing only the other respiratory pathogens (Fig 3A–3D), indicating that the primers were specific to SARS-CoV-2 (Fig 3A: 9/9 SARS-CoV-2 vs: 0/11 SARS-CoV-1 P<0.0001, vs 0/11 MERS P<0.0001; Fig 3D: 11/11 SARS-CoV-2 vs 0/11 replicas of each of 5 different respiratory pathogen pools, P<0.0001).
Fig 2

Overview of WHotLAMP assay and primers.

A. Schematic of the WHotLAMP assay. B. Location of ZI-1 LAMP primers and amplicon relative to mutations (vertical lines) defining SARS-CoV-2 variants.

Fig 3

Specificity of SARS-CoV-2 LAMP primers.

A. Representative LAMP reactions using ZI-1 LAMP primers with 1x105 copies of SARS-CoV-1 DNA (tubes 1–3), MERS DNA (tubes 4–6), SARS-CoV-2 RNA (tube 7), and no template control (tube 8). B and C, same as A but with CUFC1 or N2+E1 LAMP primers, respectively. D. Representative LAMP reactions with ZI-1 LAMP primers using WHotLAMP detecting different respiratory pathogens (Pools 1–5), no respiratory pathogens (- Ctrl), and with inactivated SARS-CoV-2 virions (+CoV-2 Ctrl). ***P<0.0001 vs. positive CoV-2 control by Fisher’s exact test.

Overview of WHotLAMP assay and primers.

A. Schematic of the WHotLAMP assay. B. Location of ZI-1 LAMP primers and amplicon relative to mutations (vertical lines) defining SARS-CoV-2 variants.

Specificity of SARS-CoV-2 LAMP primers.

A. Representative LAMP reactions using ZI-1 LAMP primers with 1x105 copies of SARS-CoV-1 DNA (tubes 1–3), MERS DNA (tubes 4–6), SARS-CoV-2 RNA (tube 7), and no template control (tube 8). B and C, same as A but with CUFC1 or N2+E1 LAMP primers, respectively. D. Representative LAMP reactions with ZI-1 LAMP primers using WHotLAMP detecting different respiratory pathogens (Pools 1–5), no respiratory pathogens (- Ctrl), and with inactivated SARS-CoV-2 virions (+CoV-2 Ctrl). ***P<0.0001 vs. positive CoV-2 control by Fisher’s exact test.

Assay consistency

To determine the consistency of RNA extraction from saliva using WHotLAMP, we designed intron-spanning LAMP primers to detect human RAB7A mRNA, a transcript expressed at high levels in multiple tissues [44]. RAB7A LAMP primers led to a yellow color change with saliva from healthy donors, but not when RNase A was added after Proteinase K treatment, indicating the amplification originated from RNA and not genomic DNA (Fig 4A and 4B). In contrast, the reaction control (RPP30) in the CDC-recommended RT-qPCR test panel for SARS-CoV-2 amplifies both genomic DNA as well as cDNA [45]. Further testing of additional saliva samples with RAB7A LAMP led to a yellow color change in 20 of 20 individual samples, indicating that the RAB7A LAMP primers are an appropriate control for benchmarking successful RNA extractions from saliva.
Fig 4

Detection of RAB7A RNA in saliva.

A. LAMP reactions using RAB7A LAMP primers with purified RNA from healthy saliva (tubes 1–3), or purified RNA treated with RNase A (tubes 4–6). B. LAMP reactions using WHotLAMP detecting RAB7A in saliva (tubes 1–3), or with RNase A treatment (tubes 4–6).

Detection of RAB7A RNA in saliva.

A. LAMP reactions using RAB7A LAMP primers with purified RNA from healthy saliva (tubes 1–3), or purified RNA treated with RNase A (tubes 4–6). B. LAMP reactions using WHotLAMP detecting RAB7A in saliva (tubes 1–3), or with RNase A treatment (tubes 4–6).

Color variation among healthy donor saliva and automated scoring of assay

To devise a quantitative colorimetric threshold from which to differentiate between positive and negative LAMP results, we photographed LAMP assays under controlled illumination using a custom-made portable photobox (Fig 5A). A potential concern regarding testing saliva using pH-sensitive dyes, rests in how the variability of pH of saliva samples could influence the specificity of this test [46]. To examine the colorimetric variability of WHotLAMP, we tested saliva samples from 36 healthy volunteers (nasal swab SARS-CoV-2 qPCR negative) and saliva samples from people with a positive nasal swab SARS-CoV-2 qPCR. Using automatic image processing, we extracted the hue of each reaction (Fig 5B). The range of hues (Fig 5C) of healthy salivas did not overlap with the range of SARS-CoV-2 positive saliva samples (n = 36 negative samples vs. n = 67 positive samples, P<0.0001), indicating unambiguous colorimetric classification of results (Fig 5D).
Fig 5

Colorimetric quantification of LAMP reactions.

A. Illuminated lightbox with automated image acquisition using Raspberry Pi. 1) Raspberry Pi unit; 2) white LED strip; 3) camera unit; 4) test tube rack. B. LAMP reactions using WHotLAMP with ZI-1 primers on saliva samples from different negative nasal-swab qPCR SARS-CoV-2 individuals (top white box) and SARS-CoV-2 positive (nasal swab) samples (bottom white box). C. Processed image showing conversion of colorimetric LAMP results to hues. D. Hue distribution of WHotLAMP saliva results from negative (-) and positive (+) nasal-swab SARS-CoV-2 qPCR donor samples. ***P<0.0001 of negative vs. positive CoV-2 samples by t-test.

Colorimetric quantification of LAMP reactions.

A. Illuminated lightbox with automated image acquisition using Raspberry Pi. 1) Raspberry Pi unit; 2) white LED strip; 3) camera unit; 4) test tube rack. B. LAMP reactions using WHotLAMP with ZI-1 primers on saliva samples from different negative nasal-swab qPCR SARS-CoV-2 individuals (top white box) and SARS-CoV-2 positive (nasal swab) samples (bottom white box). C. Processed image showing conversion of colorimetric LAMP results to hues. D. Hue distribution of WHotLAMP saliva results from negative (-) and positive (+) nasal-swab SARS-CoV-2 qPCR donor samples. ***P<0.0001 of negative vs. positive CoV-2 samples by t-test.

Limit of detection

We next performed a series of dilutions of a SARS-CoV-2 positive saliva sample to estimate the limit of detection (LoD). Using a saliva sample from an individual with a positive nasal swab Ct (threshold cycle) value of 21 using CDC nCoV N1 and N2 PCR primers to amplify the N gene, we could detect SARS-CoV-2 using WHotLAMP in 20/20 (100%) of replicate saliva samples diluted 1:20,000, and 19/20 (95%) of replicate samples diluted 1:40,000, suggesting a LoD of Ct ~36. To better quantify the LoD of our assay, we purified RNA from the same saliva and performed RT-qPCR using CDC 2019 nCoV N1 and N2 PCR primers. Through interpolation to a standard curve (R2 = 0.99) using a dilution series of a standard (IDT N-gene), we determined that the LoD of WHotLAMP with ZI-1 primers corresponds to ~3.6 viral N gene RNA copies/μL saliva. This LoD matches the 4 viral N gene RNA copies/μL of saliva determined using encapsulated SARS-CoV-2 RNA spiked into saliva (Fig 1B).

Specificity and sensitivity

To evaluate the clinical sensitivity of WHotLAMP, we tested saliva from patients who at the same time tested positive for SARS-CoV-2 with a nasal swab qPCR (See S2 Table for patient information). WHotLAMP with ZI-1 primers detected 36/38 (94.7%) positives with a Ct value up to 34 (Fig 6A) and WHotLAMP positive tests had significantly lower Ct values (P = 0.0005), indicating a higher sensitivity of WHotLAMP for samples with higher viral load. In contrast, CUFC1 primers [31] detected only 25/32 (78.1%) positives amongst the same cohort of SARS-CoV-2 saliva samples (Fig 6B) and, as with ZI-1 primers, positive tests had significantly lower Ct values (P = 0.0025). Previous reports indicate low success in culturing SARS-CoV-2 from patients with a positive nasal swab at a Ct value >34 [22, 47], suggesting that the WHotLAMP assay with ZI-1 primers can detect nearly all individuals that carry viral loads considered to be contagious. Furthermore, while the most accurate antigen tests have a false negative rate of ~20% for samples with a Ct <30 [26], WHotLAMP with ZI-1 primers detected 21/21 samples that had Ct <31 in nasal swab RT-qPCR.
Fig 6

Sensitivity and specificity of WHotLAMP.

A, B Sensitivity and C, D specificity of WHotLAMP using (A, C) ZI-1 or (B, D) CUFC1 primers with qPCR SARS-CoV-2 positive saliva. Yellow circles denote positive (+) LAMP reactions and magenta circles denote negative (-) LAMP reactions. ** P<0.001 and * P<0.01 between WHotLAMP positive and negative samples, by t-test.

Sensitivity and specificity of WHotLAMP.

A, B Sensitivity and C, D specificity of WHotLAMP using (A, C) ZI-1 or (B, D) CUFC1 primers with qPCR SARS-CoV-2 positive saliva. Yellow circles denote positive (+) LAMP reactions and magenta circles denote negative (-) LAMP reactions. ** P<0.001 and * P<0.01 between WHotLAMP positive and negative samples, by t-test. To evaluate the specificity of WHotLAMP, we tested saliva from asymptomatic individuals who had a negative qPCR result from a nasal swab taken within 24 hours of the saliva collection. Notably, we found no false positives among 40 individual samples (false-positive rate <1/40; CI = 0–0.091) using ZI-1 primers, indicating this primer set offers high specificity (Fig 6C), whereas CUFC1 primers detected 2 false positives out of 37 individual samples (a subset of the 40 tested with ZI-1; false-positive rate 0.054; CI = 0.0097–0.18) (Fig 6D).

Concluding remarks

We describe WHotLAMP, a simple and inexpensive molecular test (~$3.00 for consumables per reaction at retail prices) that does not require specialized laboratory equipment, to detect SARS-CoV-2 virus in saliva. We show that WHotLAMP can detect low levels of SARS-CoV-2 virus in saliva in 30 minutes. Its low false-positive rate allows for deployment under conditions of low prevalence, where a high test specificity is particularly important to achieve high positive predictive values. The current assay design is already applicable to test at POC settings. Moreover, its single-tube format that requires no centrifugation, is conducive to scaling to 96-well formats, but can also be adapted for home use for frequent self-administered monitoring. While here we focused on a test for SARS-CoV-2, this technology could be used to detect other pathogens that are present in saliva by substituting primers [48], making WHotLAMP a broadly useful diagnostic assay.

Methods

Saliva RNA spike-in assay

For saliva RNA spike-in tests, a 1.7 mL tube with 100 μL of saliva was combined with 100 μL lysis buffer (0.8 M guanidine hydrochloride (G3272, Sigma), 2% Tween-20 (BP337, Fisher Biotech)), mixed, and incubated at room temperature for 5 min. Approximately 1x105 copies of SARS-CoV-2 RNA (MT007544.1, TWIST Bioscience) were added to the saliva lysate and mixed. A 2x3 mm piece of Whatman No. 1 filter paper (Cat. 1001–929, GE Healthcare) was added to the lysate and incubated at room temperature for 1 min. The lysate was removed and the filter paper was washed twice. For each wash, 1 mL of wash buffer (1 mM Tris-Cl pH 8.0, 0.1 mM EDTA pH 8.0, 0.1% Tween-20) was added, inverted 20x, incubated for 1 minute at room temperature, and then removed. The filter paper was then transferred to a PCR tube containing 40 μL of 1x LAMP reaction mixture (see below). For saliva encapsulated SARS-CoV-2 RNA spike-in tests, the extraction was performed as described for the RNA spike-in assay, except that encapsulated RNA controls (either AccuPlex SARS-CoV-2 or human RNaseP, 0505–0168, LGC Sera Care) were added to the saliva lysate mixture instead of naked RNA. For the no extraction control, encapsulated SARS-CoV-2 RNA control was added directly to saliva without treatment with lysis buffer.

WHotLAMP assay

For WHotLAMP assays, a 1.7 mL tube with a piece of Whatman No.1 filter paper (approximately 6 mm2 total surface area) affixed at the bottom using Kwik-Sil™ silicone (see below) was used to carry out the entire assay. For each sample, 100 μL of saliva was loaded into the tube, followed by 50 μL of RNAlater (R0901, Sigma) and 25 μL of Proteinase K (10 mg/mL) (PB0451, BioBasic; or 25530–049, Ambion), and mixed. The tube was incubated at 26 oC for 5 min, then at 95 oC for 5 min, and then returned to room temperature. The saliva mixture was removed and the filter paper was washed twice. For the first wash, 1 mL of wash buffer (1 mM Tris-Cl pH 8.0, 0.1 mM EDTA pH 8.0, 0.1% Tween-20) was added, inverted 20x, incubated for 1 min at room temperature, and then removed. For the second wash, 1 mL of wash buffer was added and the tube was incubated for 1 min at room temperature. The wash buffer was then removed, and 50 μL of 1x LAMP reaction mixture was added. All LAMP reactions consisted of 1x colorimetric RT-LAMP mixture (NEB M1800S), 40 mM guanidine hydrochloride (G3272, Sigma, freshly made) and LAMP primers (1.6 μM FIP/BIP, 0.2 μM F3/B3, 0.4 μM LF/LB). Reactions were carried out at 65 oC for 20 minutes (for 1.7 mL tubes) in a heat block or 45 minutes (for PCR tubes) in a thermocycler. Tubes were cooled afterwards to enhance color contrast between positive and negative colorimetric LAMP results.

Assay to test for cross-reactivity of respiratory pathogens

ZI-1, CUFC1 and N2+E1 LAMP primers were used in 25 μL colorimetric RT-LAMP reactions conducted in PCR tubes. 1x105 DNA copies of SARS-CoV-1 and MERS, or RNA purified from positive SARS-CoV-2 saliva were added. Reactions were carried out at 65 oC for 45 min. To test whether ZI-1 primers had cross-reactivity with other respiratory pathogens, the WHotLAMP assay was followed, except that the 100 μL of saliva was substituted with 100 μL of respiratory pathogen mixture (20 μL of a respiratory control panel (NATRPP-1, ZeptoMetrix) or SARS-CoV-2 control (NATSARS(COV2)-ERC, ZeptoMetrix) with 80 μL water). ZeptoMetrix respiratory control panels contain the following non-infectious viral particles or bacterial cells: (Pool 1), Influenza A H1N1, Parainfluenza Type 4A and 4B, Rhinovirus (1A), Adenovirus Type 3; (Pool 2), Influenza A H1, Respiratory Syncytial Virus A, Parainfluenza Type 1, Coronavirus NL63, Mycoplasma pneumonia (M129); (Pool 3), Influenza A H3, Respiratory Syncytial Virus B, Coronavirus OC43, Coronavirus HKU-1; (Pool 4), Influenza B, Parainfluenza Type 3, Human Metapneumovirus, Legionella pneumophila; (Pool 5), Parainfluenza Type 2, Coronavirus 229E, Human Bocavirus, Chlamydophila pneumoniae.

Ethics statement

Human subject research was approved by Columbia University IRB (protocol AAAT1974) and patients provided written informed consent.

Collection and processing of patient nasal and saliva samples

Patients provided sterile cotton tipped swabs and conical tubes for sample collection. First, patients underwent separate nose and throat swabs for COVID-19 PCR analysis. For nose swabs, patients were instructed to swab 10 circles per nostril at ~1–2 cm from the nasal opening. For throat samples, patients self-swabbed. Swabs were then placed into 500 μL RLT buffer (RNeasy Mini kit, 74106, Qiagen) with 10 μL beta-mercaptoethanol per 1 mL RLT buffer. Participants were instructed, if able, to swish and swallow a small amount of water to clean the mouth. Participants were then asked to produce saliva that naturally pools in their mouth (not expectorated) into a 50 mL Falcon sterile tube. All specimens were assayed within 2 hrs or stored at 4°C for up to 48 hrs for further analysis. For RNA isolation and real-time qPCR analysis, RNA was purified using the RNeasy Mini Kit (Qiagen) with minor modifications to the standard protocol: Both the nose and throat lysates were combined on a single column for RNA isolation. In addition, only 1 RPE buffer spin was performed, followed by an 80% ethanol spin. The membrane was dried at full speed centrifugation for 5 min. RNA was eluted with two separate 20 μL RNase-free water 5 min incubations and 1 min full speed spins. RNA was transcribed into cDNA utilizing the High-Capacity cDNA Reverse Transcription Kit (Applied Biosystems) with the following thermocycler settings: 25°C for 10 min, 37°C for 60 min, 85°C for 5 min, then 4°C until used. Real-time qPCR was performed on cDNA according to standard protocols utilizing TaqPath qPCR Master Mix, ThermoScientific Microamp 96-well reaction plates, and the QuantStudio 3 Real Time PCR system. COVID-19 N1 and N2 FAM primers (2019-nCoV_N1-P, FAM-ACC CCG CAT TAC GTT TGG TGG ACC-BHQ1; 2019-nCoV_N2-P, FAM-ACA ATT TGC CCC CAG CGC TTC AG-BHQ1) were analyzed out to 40 cycles as compared to 18S rRNA VIC loading control. A 20 μL reaction was performed with 10 μL master mix, 1 μL of COVID-19 N1 or N2 primer sequence, 1 μL of 18s rRNA endogenous control, 4 μL nuclease-free water, and 4 μL RNA were added to each well. All assays were run in duplicate. Each plate was run with a COVID-19 positive control (Integrated DNA Technologies, 2019-nCoV_N_Positive Control, #10006625), and water as a negative control. Samples were deemed negative if by qPCR there was no amplification for N1 or N2. The average Ct of the duplicates was used. Saliva samples and WHotLAMP assays were handled and processed under BSL-2 containment. To test the sensitivity of WHotLAMP, patient saliva samples and negative control samples were tested under blind conditions. Saliva samples from healthy volunteers used to assess saliva variability were collected without prior food or beverage restrictions. Samples were tested using the WHotLAMP assay with 1.7 mL tubes.

Purification of RNA from saliva for RAB7A LAMP and LoD qPCR

RNA was purified from saliva samples using RNeasy Mini columns (Qiagen). 250 μL of saliva was mixed with 250 μL of RLT buffer and 500 μL of 70% ethanol. 500 μL of the mixture was loaded onto a column and centrifuged at 14,000g for 30 s. A second 500 μL volume was loaded onto the same column and centrifuged. The column was washed with 500 μL of RPE, centrifuged, transferred to a new tube, and spun to dry. The column was transferred to a fresh tube and eluted in 20 μL of water. Two additional elutions using 20 μL of water were performed, and all eluates were pooled into one tube.

cDNA synthesis for saliva LoD analysis

For cDNA synthesis, total RNA purified from saliva was reverse transcribed using random primers and recombinant M-MuLV reverse transcriptase (E6300S, NEB) according to manufacturer’s instructions. Briefly, 50 ng of total RNA was mixed with random primers and denatured for 5 min at 70°C, spun briefly, and placed on ice. M-MuLV reaction mix and M-MuLV enzyme were added to the mixture and incubated at 25°C for 5 min, then incubated at 42°C for 1 hr and heat inactivated at 80°C for 5 min. The cDNA was then stored at -20°C until further use.

qPCR for saliva LoD analysis

cDNA from SARS-CoV-2 positive saliva and positive control SARS-CoV-2 N gene DNA (2019-nCoV N positive control, IDT Cat. 10006625), were diluted in triplicate. qPCR was performed using CDC N1 and N2 gene primers, their respective fluorescent probes (2019-nCoV_N1 Probe: FAM-ACC CCG CAT TAC GTT TGG TGG ACC-BHQ1 and 2019-nCoV_N2-Probe: FAM-ACA ATT TGC CCC CAG CGC TTC AG-BHQ1) and Taqman Fast Advanced master mix (ThermoFisher, Cat. 4444551), and a QuantStudio 3 Real-Time PCR system (Applied Biosystems) using recommended CDC 2019 nCoV RT-PCR thermocycling parameters. Ct values falling within the linear amplification range were used to estimate SARS-CoV-2 copy number in the cDNA, and an estimated LoD based on copy number was calculated based on the dilutions.

RT-LAMP primers

Primers (desalted, Integrated DNA Technologies and Eurofins Genomics) used for LAMP reactions were prepared in water as 10x stocks (16 μM FIP/BIP, 2 μM F3/B3, 4 μM LF/LB) (see Table 2). ZI LAMP primer sets were identified using the NEB Primer Design Tool (https://lamp.neb.com/#!/) and a ~800 bp sliding window across the SARS-CoV-2 genomic sequence (MN908947.3). Primer sets with low primer ΔG values (e.g. <-2.2) were selected for further analysis. One primer set, ZI-1, was selected because it was highly sensitive when tested using positive SARS-CoV-2 saliva.
Table 2

Primers used in study.

PrimerSequence
ZI-1-F3 5’ GGA TAC AAC TAG CTA CAG AGA A 3’
ZI-1-B3 CCA CAA GTT ACT TGT ACC ATA C
ZI-1-FIP TTG GTA AAG AAC ATC AGA ACC TGA GGC TGC TTG TTG TCA TCT C
ZI-1-BIP CCA CCA CAA ACC TCT ATC ACC TAA CCC TCA ACT TTA CCA GAT
ZI-1-LF AAG TCA TTG AGA GCC TTT GC
ZI-1-LB GTG GTT TTA GAA AAA TGG CAT TCC C
CUFC1-F3 TGG ATA CAA CTA GCT ACA GAG AAG
CUFC1-B3 AGC CAA AGA CCG TTA AGT GTA
CUFC1-FIP GTG GTG GTT GGT AAA GAA CAT CAG ACT TGT TGT CAT CTC GCA AAG G
CUFC1-BIP CCT CTA TCA CCT CAG CTG TTT TGC TGT ACC ATA CAA CCC TCA ACT T
CUFC1-LF ACC TGA GTT ACT GAA GTC ATT GAG A
CUFC1-LB TGG TTT TAG AAA AAT GGC ATT CCC
N2-F3 ACC AGG AAC TAA TCA GAC AAG
N2-B3 GAC TTG ATC TTT GAA ATT TGG ATCT
N2-FIP TTC CGA AGA ACG CTG AAG CGG AAC TGA TTA CAA ACA TTG GCC
N2-BIP CGC ATT GGC ATG GAA GTC ACA ATT TGA TGG CAC CTG TGT A
N2-LF GGG GGC AAA TTG TGC AAT TTG
N2-LB CTT CGG GAA CGT GGT TGA CC
E1-F3 TGA GTA CGA ACT TAT GTA CTC AT
E1-B3 TTC AGA TTT TTA ACA CGA GAG T
E1-FIP ACC ACG AAA GCA AGA AAA AGA AGT TCG TTT CGG AAG AGA CAG
E1-BIP TTG CTA GTT ACA CTA GCC ATC CTT AGG TTT TAC AAG ACT CAC GT
E1-LB GCG CTT CGA TTG TGT GCG T
E1-LF CGC TAT TAA CTA TTA ACG
RAB7A-F3 ACA GGC CTG GTG CTA CAG
RAB7A-B3 CTG CAG CTT TCT GCC GAG
RAB7A-FIP CAA TCG TCT GGA ACG CCT GCT CCC TAC TTT GAG ACC AGT GC
RAB7A-BIP AAG CAG GAA ACG GAG GTG GAG GCC CGG TCA TTC TTG TCC
RAB7A-LF ACG TTG ATG GCC TCC TTG
RAB7A-LB TGT ACA ACG AAT TTC CTG AAC C
2019-nCoV_N1-F GAC CCC AAA ATC AGC GAA AT
2019-nCoV_N1-R TCT GGT TAC TGC CAG TTG AAT CTG
2019-nCoV_N1-PFAM-ACC CCG CAT TAC GTT TGG TGG ACC-BHQ1
2019-nCoV_N2-F TTA CAA ACA TTG GCC GCA AA
2019-nCoV_N2-R GCG CGA CAT TCC GAA GAA
2019-nCoV_N2-PFAM-ACA ATT TGC CCC CAG CGC TTC AG-BHQ1

WHotLAMP LoD assay

SARS-CoV-2 positive saliva was initially heat-inactivated at 65 oC for 30 min prior to diluting using negative control saliva. An initial series using 10-fold dilutions was tested using WHotLAMP with ZI-1 primers. A second series using 2-fold dilutions was tested and repeated 20 times to estimate the consistency at the LoD. Saliva from the same SARS-CoV-2 positive sample was used to extract RNA for RT-qPCR analysis.

Adhesive and material handling and testing

Adhesives that could be used to affix Whatman No. 1 filter paper to the bottom of a tube were tested to determine if they were compatible with the LAMP colorimetric assay. A small quantity of liquid adhesives (~2 μL) was spotted at the bottom of a tube and allowed to cure for at least 24 hrs. For solid materials, ~1–2 mm2 pieces were used. Tubes containing different adhesives were incubating in 1x LAMP reaction mixture at 65 oC for 20 min (for 1.7 mL tubes) or 45 min (for 0.2 mL PCR tubes). Materials tested were, silicones (Kwik-Sil™ silicone elastomer [World Precision Instruments], aquarium silicone [Aqueon], neutral cure silicone [Dow Corning 737]), liquid glues (Gorilla glue [original, polyurethane], Crazy Glue [Loctite]), glue gun sticks (polyamide [Power Adhesives TEC Bond 7718], acrylic [Infinity Bond], Hot Melt Mini Glue Sticks [Allary]), rubber cement (paper cement [Best-Test]), double-sided tape (Permanent [Scotch, 3M]), plastic strip, (cut from a 175 micron polyester sheet [Grafix Plastics]). To prepare large numbers of 1.7 mL tubes with Whatman No. 1 filter paper glued with Kwik-Sil™, a small aliquot of component A and component B were mixed together and placed on ice to slow the polymerization process. Tear-shaped Whatman filter paper pieces were prepared using a hole-punch. The tapered end of the paper was dipped slightly in Kwik-Sil™ and placed, taper side facing up, at the bottom of the 1.7 mL tube using fine-tipped forceps, and air dried for at least 24 hrs.

Raspberry Pi lightbox

To quantify colorimetric ranges under uniform conditions we embedded an enclosed white box with: 1) a Raspberry Pi 3 (model B+), 2) camera unit (camera v2.1), and 3) white LED lights (DC12V LED strip). The raspistill command line tool was run to capture still images (raspistill—raw -o png). A color chart (Digital Kolor Kard) inside the box was used as reference to calibrate the white balance of images. Images were then used to extract hues to interpret WHotLAMP positive and negative colorimetric results.

Image processing

We developed a proof-of-concept image analysis pipeline that identified sample results. Images of an array of samples were acquired and thresholded based on color saturation to identify regions of interest (ROIs) corresponding to samples. Areas of high or low brightness as well as areas near the image border were excluded from potential ROIs. We found that this method successfully identified correct ROIs and that the average hue within each ROI formed a bimodal distribution that could be used to successfully categorize samples into positives and negatives.

Statistical analysis

Statistical analyses of colorimetric data were performed using Fisher’s exact tests for frequencies (Fig 3A and 3D) and a t-test for continues hue values (Figs 5D, 6A and 6B). Sample sizes were: Fig 3A: n = 9 positives, n = 11 for each negative control group; Fig 3D, n = 9 positives and n = 9 for each negative control pool; Fig 5D, n = 36 negative samples, n = 67 nasal qPCR positive SARS-CoV-2 saliva samples; Fig 6A, n = 51 nasal qPCR positive SARS-CoV-2 saliva samples; Fig 5B, n = 46 nasal qPCR positive SARS-CoV-2 saliva samples.

SARS-CoV-2 mutations.

(XLSX) Click here for additional data file.

Patient information.

(XLSX) Click here for additional data file.

WHotLAMP protocol.

(PDF) Click here for additional data file.

Python code for LAMP colorimetric result analysis.

(PDF) Click here for additional data file. 4 Aug 2021 PONE-D-21-23691 WHotLAMP: A simple, inexpensive, and sensitive molecular test for the detection of SARS-CoV-2 in saliva PLOS ONE Dear Dr. Bendesky, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please revise the point about statistics. Please submit your revised manuscript by Sep 16 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Etsuro Ito Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. We note that you have a patent relating to material pertinent to this article. Please provide an amended statement of Competing Interests to declare this patent (Patent application 63/088,694), along with any other relevant declarations relating to employment, consultancy, patents, products in development or modified products etc. Please confirm that this does not alter your adherence to all PLOS ONE policies on sharing data and materials, as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” If there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. This information should be included in your cover letter; we will change the online submission form on your behalf. Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: I Don't Know ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The WHotLAMP manuscript from Ng et al presents a very good colorimetric LAMP assay for SARS-CoV-2 detection. There have been quite a few of these published now but the performance, simplicity, and novelty in this approach justify publication. The manuscript is clear and well written, and I feel it can be accepted mostly as is after addressing a few comments listed below. 1) The authors use an Orf1 primer set, it would be good to note whether the targeted region is anywhere close to the SGF deletion found in alpha, beta, gamma, and lambda variants which may affect performance. Related, the LOD is measured using quantitative PCR with N gene primers, a comment on the veracity of the assumption that 1 N=1 Orf1 would be good. 2) The authors describe spiking naked control RNA into saliva and then using it for detection. Other studies and conventional wisdom would say this wouldn't work and that the RNA is degraded extremely rapidly. Is there a reason it works here w/o RNase inactivation? 3) In describing the LoD the authors say that their assay is ">50X more sensitive than other recent saliva LAMP assays" which is a bit unfair considering this is contrived samples, data in Fig. 5A doesn't really indicate a "50X" sensitivity improvement. Plus there are a lot of LAMP assays, picking 1 for LOD comparison doesn't quite justify a claim of superiority to "other assays". Reviewer #2: Ng et al. have performed an interesting and clear study that may benefit the fight against the Covid-19 pandemic. The paper is clearly written and details a novel test for detecting the covid-19 spike protein in what appears to be a specific assay. The benefit of the assay is how easy it is to handle and that it can be translated to something that can be done at home, which allows more people to access a safe and specific covid-19 assay. Major comments: After reading the manuscript through and through several times, I can only make out one statistical test, however what test this was used is not mentioned. The Paper would greatly benefit from adding statistics throughout the paper and the statistics should be described in detail in the material and methods. It is not clear how many samples that has been analyzed, there is a mention of 20/20 positive samples and then 21/21. A table of the patient/sample characteristics detailing the number of positive samples, the severity of disease, negative controls and other diseases would greatly benefit the paper. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Daniel Butler While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 31 Aug 2021 We appreciate the thoughtful reviews and the opportunity to respond to the Reviewers’ concerns and suggestions. As detailed below, we have addressed all points by adding new data and statistical tests, new analyses and figures, and rewriting sections of the manuscript to improve clarity. Reviewer 1: 1) The authors use an Orf1 primer set, it would be good to note whether the targeted region is anywhere close to the SGF deletion found in alpha, beta, gamma, and lambda variants which may affect performance. We have added a new figure panel (Figure 2B) that shows how our LAMP amplicon does not overlap any mutations in the alpha, beta, gamma, nor delta variants, suggesting our assay should be able to detect all these SARS-CoV-2 variants. Related, the LOD is measured using quantitative PCR with N gene primers, a comment on the veracity of the assumption that 1 N=1 Orf1 would be good. While SARS-CoV-2 virions package a single RNA genome, it is true that different SARS-CoV-2 genes are present at different levels in infected cells (Kim et al., 2020). In Figure 1B, we quantified the sensitivity of our assay using contrived saliva samples spiked with synthetic virions each containing single RNA viral copies (so each viral gene is 1 copy) and using LAMP primers targeting the N and E genes. This showed that we could detect as few as 4 viral particles per microliter of saliva (Fig 1A). As a more realistic measure of the limit of detection of our assay, we quantified the number of N gene RNA copies in saliva from COVID-19 patients through qPCR using the CDC approved N gene primers. This, followed by serial dilutions of these saliva samples showed that our LAMP assay has a limit of detection of ~3.6 N gene RNA copies per microliter of saliva. We have rewritten the text so it is clear that our limit of detection in saliva with people with COVID-19 is measured in terms of RNA copies of the N gene. 2) The authors describe spiking naked control RNA into saliva and then using it for detection. Other studies and conventional wisdom would say this wouldn't work and that the RNA is degraded extremely rapidly. Is there a reason it works here w/o RNase inactivation? We agree with the reviewer that because of the high level of RNases present in saliva, direct spike-in of naked RNA into saliva would lead to rapid degradation, as we (data not shown) and others have observed. In this assay (Figure 1A in the original manuscript), our goal was to determine whether Whatman paper had the potential to capture SARS-CoV-2 RNA in saliva. We would like to point out to that in this assay, saliva was initially mixed and pre-incubated with a lysis buffer with a final concentration of 0.4 M guanidine hydrochloride (GH) before the addition of naked RNA. Although the concentration of GH is insufficient to denature and fully inactivate RNases, it has been reported that low concentrations of GH can partially inactivate RNaseA very rapidly. For example at a concentration of 0.5 M GH, about 50% of RNaseA activity is lost (Liu and Tsou, 1987). While the precise species of RNase(s) in the saliva samples is not known, this study supports the notion that pre-treatment with GH inhibits some ribonuclease activity. We suggest that under the conditions used in this assay, there is partial inactivation of RNases in the saliva sample during the pre-incubation step. Combined with the high number (100,000) of RNA copies added and brief incubation time with Whatman paper (~1 min) before washing, sufficient RNA target is bound to the filter paper to be detected using LAMP. Because RNases are likely only partially inactivated under these conditions, we suspect that longer exposure times of naked RNA to saliva will lead to the complete degradation of the RNA target. The details of the conditions used in this assay are present in the Methods section in the original manuscript (lines 203-211), including composition of the lysis buffer and incubation times. Of note, we performed these experiments using naked RNA spiked into saliva only in Fig 1A as a proof of principle that RNA can bind the Whatman paper in the context of saliva. In Fig 1B we use synthetic (encapsulated RNA) viral particles; in subsequent Figures using saliva, samples were incubated with RNAlater to inhibit RNase activity. In Fig 4 we show how we can detect endogenous human mRNA (as positive control of the assay); and in Fig 5 and Fig 6 we show how our assay detects SARS-CoV-2 RNA in real COVID-19 patients. Kim, D., Lee, J.-Y., Yang, J.-S., Kim, J.W., Kim, V.N, and Chang, H. The Architecture of SARS-CoV-2 Transcriptome. Cell 181:914-921 (2020). Liu, W., and Tsou, C.L. Activity change during unfolding of bovine pancreatic ribonuclease A in guanidine. Biochimica et Biophysica Acta 916:455-464 (1987). 3) In describing the LoD the authors say that their assay is ">50X more sensitive than other recent saliva LAMP assays" which is a bit unfair considering this is contrived samples, data in Fig. 5A doesn't really indicate a "50X" sensitivity improvement. Plus there are a lot of LAMP assays, picking 1 for LOD comparison doesn't quite justify a claim of superiority to "other assays". We have revised this section according to this comment to not refer to a 50X improvement in sensitivity. Reviewer 2: The Paper would greatly benefit from adding statistics throughout the paper and the statistics should be described in detail in the material and methods. Thank you for the suggestion. We have now increased our sample sizes in many parts of the paper and added statistical tests throughout (in main text and in figures), all of which support our observations and previous conclusions. We have a new section in the Methods explaining the statistical tests and the sample sizes. We also revised the data in the automatic quantification of WHotLAMP results using image analysis to remove some technical replicates. This removal did not change the non-overlapping distributions of hues between positive and negative samples and this difference in distributions in highly significant (P<0.0001). It is not clear how many samples that has been analyzed, there is a mention of 20/20 positive samples and then 21/21. A table of the patient/sample characteristics detailing the number of positive samples, the severity of disease, negative controls and other diseases would greatly benefit the paper. We have included a new Supplementary Table with details on numbers of COVID-19 patients tested, the severity of disease and other clinical details. We have also clarified throughout the revised manuscript the number of samples used in each experiment and also in a new section on Statistical analysis in the Methods. Submitted filename: 20210830_response_to_reviewers.docx Click here for additional data file. 2 Sep 2021 WHotLAMP: A simple, inexpensive, and sensitive molecular test for the detection of SARS-CoV-2 in saliva PONE-D-21-23691R1 Dear Dr. Bendesky, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Etsuro Ito Academic Editor PLOS ONE 7 Sep 2021 PONE-D-21-23691R1 WHotLAMP: A simple, inexpensive, and sensitive molecular test for the detection of SARS-CoV-2 in saliva Dear Dr. Bendesky: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Prof. Etsuro Ito Academic Editor PLOS ONE
  38 in total

1.  How to perform a nasopharyngeal swab in adults and children in the COVID-19 era.

Authors:  S Pondaven-Letourmy; F Alvin; Y Boumghit; F Simon
Journal:  Eur Ann Otorhinolaryngol Head Neck Dis       Date:  2020-06-05       Impact factor: 2.080

2.  Direct on-the-spot detection of SARS-CoV-2 in patients.

Authors:  Nadav Ben-Assa; Rawi Naddaf; Tal Gefen; Tal Capucha; Haitham Hajjo; Noa Mandelbaum; Lilach Elbaum; Peter Rogov; Daniel A King; Shai Kaplan; Assaf Rotem; Michal Chowers; Moran Szwarcwort-Cohen; Mical Paul; Naama Geva-Zatorsky
Journal:  Exp Biol Med (Maywood)       Date:  2020-07-16

3.  Clarifying the evidence on SARS-CoV-2 antigen rapid tests in public health responses to COVID-19.

Authors:  Michael J Mina; Tim E Peto; Marta García-Fiñana; Malcolm G Semple; Iain E Buchan
Journal:  Lancet       Date:  2021-02-17       Impact factor: 79.321

4.  Neutralization of SARS-CoV-2 lineage B.1.1.7 pseudovirus by BNT162b2 vaccine-elicited human sera.

Authors:  Alexander Muik; Ann-Kathrin Wallisch; Bianca Sänger; Kena A Swanson; Julia Mühl; Wei Chen; Hui Cai; Daniel Maurus; Ritu Sarkar; Özlem Türeci; Philip R Dormitzer; Uğur Şahin
Journal:  Science       Date:  2021-01-29       Impact factor: 47.728

5.  Comparison of Rapid Antigen Tests for COVID-19.

Authors:  Seiya Yamayoshi; Yuko Sakai-Tagawa; Michiko Koga; Osamu Akasaka; Ichiro Nakachi; Hidefumi Koh; Kenji Maeda; Eisuke Adachi; Makoto Saito; Hiroyuki Nagai; Kazuhiko Ikeuchi; Takayuki Ogura; Rie Baba; Kensuke Fujita; Takahiro Fukui; Fumimaro Ito; Shin-Ichiro Hattori; Kei Yamamoto; Takato Nakamoto; Yuri Furusawa; Atsuhiro Yasuhara; Michiko Ujie; Shinya Yamada; Mutsumi Ito; Hiroaki Mitsuya; Norio Omagari; Hiroshi Yotsuyanagi; Kiyoko Iwatsuki-Horimoto; Masaki Imai; Yoshihiro Kawaoka
Journal:  Viruses       Date:  2020-12-10       Impact factor: 5.048

6.  Nucleic acid purification from plants, animals and microbes in under 30 seconds.

Authors:  Yiping Zou; Michael Glenn Mason; Yuling Wang; Eugene Wee; Conny Turni; Patrick J Blackall; Matt Trau; Jose Ramon Botella
Journal:  PLoS Biol       Date:  2017-11-21       Impact factor: 8.029

7.  Assessment of SARS-CoV-2 Screening Strategies to Permit the Safe Reopening of College Campuses in the United States.

Authors:  A David Paltiel; Amy Zheng; Rochelle P Walensky
Journal:  JAMA Netw Open       Date:  2020-07-01

8.  Viral shedding patterns of coronavirus in patients with probable severe acute respiratory syndrome.

Authors:  Peter K C Cheng; Derek A Wong; Louis K L Tong; Sin-Ming Ip; Angus C T Lo; Chi-Shan Lau; Eugene Y H Yeung; Wilina W L Lim
Journal:  Lancet       Date:  2004-05-22       Impact factor: 79.321

9.  Saliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2.

Authors:  Anne L Wyllie; John Fournier; Arnau Casanovas-Massana; Melissa Campbell; Maria Tokuyama; Pavithra Vijayakumar; Joshua L Warren; Bertie Geng; M Catherine Muenker; Adam J Moore; Chantal B F Vogels; Mary E Petrone; Isabel M Ott; Peiwen Lu; Arvind Venkataraman; Alice Lu-Culligan; Jonathan Klein; Rebecca Earnest; Michael Simonov; Rupak Datta; Ryan Handoko; Nida Naushad; Lorenzo R Sewanan; Jordan Valdez; Elizabeth B White; Sarah Lapidus; Chaney C Kalinich; Xiaodong Jiang; Daniel J Kim; Eriko Kudo; Melissa Linehan; Tianyang Mao; Miyu Moriyama; Ji E Oh; Annsea Park; Julio Silva; Eric Song; Takehiro Takahashi; Manabu Taura; Orr-El Weizman; Patrick Wong; Yexin Yang; Santos Bermejo; Camila D Odio; Saad B Omer; Charles S Dela Cruz; Shelli Farhadian; Richard A Martinello; Akiko Iwasaki; Nathan D Grubaugh; Albert I Ko
Journal:  N Engl J Med       Date:  2020-08-28       Impact factor: 176.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.