| Literature DB >> 34490194 |
Tatjana Paunesku1, Andrew C Gordon2, Sarah White3, Kathleen Harris2, Olga Antipova4, Evan Maxey4, Stefan Vogt4, Anthony Smith1, Luiza Daddario1, Daniele Procissi2, Andrew Larson2, Gayle E Woloschak1.
Abstract
Introduction: TheraSphere® microspheres containing yttrium 90Y are among many radioembolization agents used clinically to reduce liver tumor burden, and their effects on cancer volume reduction are well-established. At the same time, concerns about off target tissue injury often limit their use. Deeper investigation into tissue distribution and long-term impact of these microspheres could inform us about additional ways to use them in practice.Entities:
Keywords: X-ray fluorescence microscopy; hepatocellular carcinoma; rabbit (Lagomorph); radioembolization of liver malignancies; yttrium 90 microspheres
Mesh:
Substances:
Year: 2021 PMID: 34490194 PMCID: PMC8417723 DOI: 10.3389/fpubh.2021.711506
Source DB: PubMed Journal: Front Public Health ISSN: 2296-2565
Administered activity (primarily 90Y, for additional explanation see Table 2) on the day of animal treatment.
|
|
|
|
|---|---|---|
| Rabbit 843382 | 80,586,899.58 | 10/25/15 |
| Rabbit 827185 | 92,169,487.58 | 8/23/15 |
| Rabbit 827186 | 69,696,624.87 | 8/23/15 |
| Rabbit 762071 | 84,036,896.28 | 11/9/14 |
| “Rat 21” | 33,881,260.94 | 10/25/15 |
MDS Nordion measurement of by-products at 60 days post-calibration for TheraSphere with Calibration dates after January 1, 2010.
|
|
|
|
| |
|---|---|---|---|---|
|
|
|
|
| |
| Y-91 | 58.51 | 1,204.7 | 2,504 | 271 |
| Y-88 | 106.65 | 898 | 895 | 64 |
| Cr-51 | 27.7 | 320.1 | 78.9 | 9.1 |
| Total for all other nuclides: | 81 | 7.5 | ||
Figure 1Rat liver tissue elemental map obtained with 30 micron spot size scanning, X-ray energy 15 keV (Station 8BM-B). Elemental maps were obtained simultaneously while sample was moved by rapid raster scanning (so called: “fly scans”) through the X-ray beam. Scale bar−2 mm, color bar indicates elemental quantity as represented by false colors, from black (no signal) to red (highest signal). Hematoxylin and eosin (H&E) staining of the same region in one of the adjacent tissue sections is shown in the right-hand panel. White diamonds in Si and Y maps correspond to a TheraSpheres rich area; white circle indicates fibrotic area in Fe map and H&E image. Orange rectangle in Fe image and black rectangle in H&E image correspond to areas shown in Figure 2 (due to imaging setup, in Figure 2 these areas are horizontally flipped).
Figure 2Elemental map of a detail of rat liver tissue obtained with 300 nanometer spot size (station 2ID-E), X-ray energy 21 keV. At this x-ray energy fluorescence produced by yttrium overwhelms signals of most biological elements and the speres “appear in all elemental channels.” Elemental maps were obtained simultaneously while sample was moved by rapid raster scanning (so called: “fly scans”) through the X-ray beam. Scale bar−200 microns, color bar indicates elemental quantity as represented by false colors, from black (no signal) to red (highest signal). Elemental signal maxima in micrograms per cm square for different elements were: 804 for Si, 14.5 for S, 0.499 for Cu, 37.1 for Fe, 7.79 for Zn and 774 for Y. Hematoxylin and eosin staining of the same region in one of the adjacent tissue sections is shown in the right hand panel; white arrow points to a TheraSphere. Please note that the same areas were scanned at lower magnification in Figure 1, as explained.
Figure 3A detail of rat liver tissue elemental map obtained with 300 nanometer spot size (station 2ID-E), X-ray energy 21 keV. Scale bar −100 microns, color bar indicates elemental quantity as represented by false colors, from black (no signal) to red (highest signal). Signal maxima in micrograms per cm square for different elements were: 125 for Si, 5.45 for S, 0.199 for Cu, 50.9 for Fe, 23.7 for Zn, and 0.635 for Y.
Figure 4Rabbit liver with VX2 tumor necrotic region (left half of the sample) and VX2 viable part of the tumor (right-hand side of the sample). Elemental map was obtained with 30 micron spot size scanning, at X-ray energy 15 keV (station 8BM-B). Scale bar−2 mm, color bar indicates elemental quantity as represented by false colors, from black (no signal) to red (highest signal). Hematoxylin and eosin staining of the same region in one of the adjacent tissue sections is shown in the right hand panel.