Literature DB >> 34429599

Neutral Nonenzymatic Glucose Biosensors Based on Electrochemically Deposited Pt/Au Nanoalloy Electrodes.

Fang-Yu Lin1, Pei-Yuan Lee1,2, Tien-Fu Chu3, Chang-I Peng3, Gou-Jen Wang1,3,4.   

Abstract

BACKGROUND: Type I diabetes occurs when the pancreas can only make limited or minimal insulin. Patients with type 1 diabetes need effective approaches to manage diabetes and maintain their blood-glucose concentration. Recently, continuous glucose monitoring (CGM) has been used to help control blood-glucose levels in patients with type 1 diabetes. Patients with type 2 diabetes may also benefit from CGM on multiple insulin injections, basal insulin, or sulfonylureas. Enzyme-free glucose detection in a neutral environment is the recent development trend of CGM.
MATERIALS AND METHODS: Pt/Au alloy electrodes for enzyme-free glucose detection in a neutral environment were formed by electrochemically depositing Pt/Au alloy on a thin polycarbonate (PC) membrane surface with a uniformly distributed micro-hemisphere array. The PC membranes were fabricated using semiconductor microelectromechanical manufacturing processes, precision micro-molding, and hot embossing. Amperometry was used to measure the glucose concentration in PBS (pH 7.4) and artificial human serum.
RESULTS: The Pt/Au nanoalloy electrode had excellent specificity for glucose detection, according to the experimental results. The device had a sensitivity of 2.82 μA mM-1 cm-2, a linear range of 1.39-13.9 mM, and a detection limit of 0.482 mM. Even though the complex interfering species in human blood can degrade the sensing signal, further experiments conducted in artificial serum confirmed the feasibility of the proposed Pt/Au nanoalloy electrode in clinical applications.
CONCLUSION: The proposed Pt/Au nanoalloy electrode can catalyze glucose reactions in neutral solutions with enhancing sensing performance by the synergistic effect of bimetallic materials and increasing detection surface area. This novel glucose biosensor has advantages, such as technology foresight, good detection performance, and high mass production feasibility. Thus, the proposed neutral nonenzymatic glucose sensor can be further used in CGMs.
© 2021 Lin et al.

Entities:  

Keywords:  Pt/Au nanoalloy electrode; electrochemical deposition; neutral nonenzymatic glucose biosensor; synergistic effect

Mesh:

Substances:

Year:  2021        PMID: 34429599      PMCID: PMC8379712          DOI: 10.2147/IJN.S321480

Source DB:  PubMed          Journal:  Int J Nanomedicine        ISSN: 1176-9114


  17 in total

1.  Printing graphene-carbon nanotube-ionic liquid gel on graphene paper: Towards flexible electrodes with efficient loading of PtAu alloy nanoparticles for electrochemical sensing of blood glucose.

Authors:  Wenshan He; Yimin Sun; Jiangbo Xi; Abduraouf Alamer Mohamed Abdurhman; Jinghua Ren; Hongwei Duan
Journal:  Anal Chim Acta       Date:  2015-11-28       Impact factor: 6.558

2.  A Review of Continuous Glucose Monitoring Data Interpretation in the Age of Automated Insulin Delivery.

Authors:  Laya Ekhlaspour; Ideen Tabatabai; Bruce Buckingham
Journal:  J Diabetes Sci Technol       Date:  2019-05-26

Review 3.  Accuracy of point-of-care glucose measurements.

Authors:  Annette Rebel; Mark A Rice; Brenda G Fahy
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

4.  Electrochemical non-enzymatic glucose sensors.

Authors:  Sejin Park; Hankil Boo; Taek Dong Chung
Journal:  Anal Chim Acta       Date:  2005-07-11       Impact factor: 6.558

5.  Bimetallic Pt-Au nanocatalysts electrochemically deposited on graphene and their electrocatalytic characteristics towards oxygen reduction and methanol oxidation.

Authors:  Yaojuan Hu; Hua Zhang; Ping Wu; Hui Zhang; Bo Zhou; Chenxin Cai
Journal:  Phys Chem Chem Phys       Date:  2011-01-13       Impact factor: 3.676

Review 6.  Automated blood glucose control in type 1 diabetes: A review of progress and challenges.

Authors:  Arthur Bertachi; Charrise M Ramkissoon; Jorge Bondia; Josep Vehí
Journal:  Endocrinol Diabetes Nutr (Engl Ed)       Date:  2017-12-24       Impact factor: 1.417

Review 7.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

Review 8.  Continuous glucose monitoring: A review of the technology and clinical use.

Authors:  David C Klonoff; David Ahn; Andjela Drincic
Journal:  Diabetes Res Clin Pract       Date:  2017-09-01       Impact factor: 5.602

Review 9.  Combining continuous glucose monitoring and insulin pumps to automatically tune the basal insulin infusion in diabetes therapy: a review.

Authors:  Martina Vettoretti; Andrea Facchinetti
Journal:  Biomed Eng Online       Date:  2019-03-29       Impact factor: 2.819

10.  General synthesis of hierarchical sheet/plate-like M-BDC (M = Cu, Mn, Ni, and Zr) metal-organic frameworks for electrochemical non-enzymatic glucose sensing.

Authors:  Gilang Gumilar; Yusuf Valentino Kaneti; Joel Henzie; Sauvik Chatterjee; Jongbeom Na; Brian Yuliarto; Nugraha Nugraha; Aep Patah; Asim Bhaumik; Yusuke Yamauchi
Journal:  Chem Sci       Date:  2020-03-12       Impact factor: 9.825

View more
  1 in total

1.  Sensors and digital medicine in orthopaedic surgery.

Authors:  Géraldine Merle; Alexandre Parent-Harvey; Edward J Harvey
Journal:  OTA Int       Date:  2022-04-18
  1 in total