| Literature DB >> 34307922 |
David Bird1,2, Matthew Beasley1, Michael G Nix1, Marcus Tyyger1, Hazel McCallum3,4, Mark Teo1, Alexandra Gilbert1,2, Nathalie Casanova1, Rachel Cooper1, David L Buckley5, David Sebag-Montefiore1,2, Richard Speight1, Ann M Henry1,2, Bashar Al-Qaisieh1.
Abstract
BACKGROUND ANDEntities:
Keywords: Anal cancer; CBCT; CBCT patient positioning; MR-only; MRI-only; Rectal cancer
Year: 2021 PMID: 34307922 PMCID: PMC8295842 DOI: 10.1016/j.phro.2021.07.005
Source DB: PubMed Journal: Phys Imaging Radiat Oncol ISSN: 2405-6316
The scan parameters for patient CT, MR and CBCT scans.
| MR | Make & Model | Siemens Aera 1.5 T |
| Sequence | 3D T2 SPACE | |
| Resolution | 0.9 × 0.9 × 1.5 mm3 | |
| Refocusing Flip Angle (°) | 160 | |
| TR (ms) | 1600 | |
| TE (ms) | 211 | |
| Bandwidth (Hz/px) | 545 | |
| Echo train length | 134 | |
| Longitudinal scan length | Standard: 2 cm inferior of genitalia to L5 vertebra | |
| Field of View (Axial) | 450 × 450 mm2 | |
| CT | Make & Model | Philips Brilliance Big Bore |
| Resolution | 1.2 × 1.2 × 2 mm3 | |
| kVp (kV) | 120 | |
| X-ray Tube Current (mAs) | 135 | |
| Field of View (Axial) | 450 × 450 mm2 | |
| CBCT | Make & Model | Elekta XVI |
| Resolution | 1 × 1 × 1 mm3 | |
| kVp (kV) | 120 | |
| X-ray Tube Current (mAs) | 32 | |
| Field of View (Axial) | 400 mm diameter | |
Fig. 1Example of an axial slice of a single anal cancer patient CT (top left), MR (top right), sCT (bottom left) and CBCT (bottom right) scan used for CBCT registrations.
CBCT registration standard protocol clip box size parameters for anal and rectal cancer sites, and the large extended clip box.
| Protocol | Dimension | Anatomy to Include | Anatomy to exclude |
|---|---|---|---|
| Anus | Left/Right | Pelvic cavity | Femoral Heads |
| Ant/Post | Pubic symphysis | Sacrum | |
| Sup/Inf | PTV | Sacrum | |
| Rectum | Left/Right | Pelvic cavity | Femoral Heads |
| Ant/Post | Sacrum | Pubic symphysis | |
| Sup/Inf | Whole Sacrum & PTV | X | |
| Extended clip box | Left/Right | Femoral Heads | X |
| Ant/Post | Pubic symphysis and Sacrum | X | |
| Sup/Inf | Pubic symphysis and Sacrum | X | |
Fig. 2Example CBCT registration clip boxes for anal (A) and rectal (B) cancer sites respectively as positioned on a reference CT image.
The translational and rotational (x (left–right/rotation), y (anterior-posterior/pitch) and z(superior-inferior/yaw)) effect sizes and 95% confidence intervals from the linear mixed effects modelling for MR and synthetic-CT as compared to CT for anal and rectal cancers respectively.
| Reference image (vs. CT) | Dimension | Translations (mm) | Rotations (o) | |
|---|---|---|---|---|
| Effect size (95% confidence intervals) | Effect size (95% confidence intervals) | |||
| Anus | MR | x | −0.3 (−1.0; 0.4) | 0.4 (0.1; 0.7) |
| y | 0.3 (−0.4; 1.1) | −0.1 (−0.4; 0.2) | ||
| z | 0.1 (−0.6; 0.8) | 0.1 (−0.2; 0.5) | ||
| sCT | x | −0.4 (−1.1; 0.3) | 0.2 (−0.1; 0.5) | |
| y | 0.8 (0.0; 1.5) | −0.1 (−0.5; 0.2) | ||
| z | 0.3 (−0.4; 1.0) | 0.1 (−0.3; 0.4) | ||
| Rectum | MR | x | 0.0 (−0.6; 0.7) | 0.0 (−0.4; 0.4) |
| y | −0.4 (−1.0; 0.2) | 0.1 (−0.3; 0.5) | ||
| z | −0.3 (−0.9; 0.3) | 0.0 (−0.4; 0.4) | ||
| sCT | x | −0.2 (−0.8; 0.4) | −0.1 (−0.5; 0.3) | |
| y | −0.6 (−1.2; 0.0) | 0.1 (−0.3; 0.4) | ||
| z | 0.2 (−0.5; 0.8) | 0.0 (−0.4; 0.3) | ||
Fig. 3The translational and rotational (x (left–right/rotation), y (anterior-posterior/pitch) and z(superior-inferior/yaw)) MR and sCT CBCT registration differences to CT for anal and rectal cancer sites, where differences were calculated as the MR or sCT value minus the CT value.