Literature DB >> 34305290

Evaluation of implantable Doppler probe continuous monitoring of hepatic artery anastomosis after liver transplantation.

Shrirang Vasant Kulkarni1, Pankaj P Rao2, C S Naidu3, N Pathak4, A K Singh5.   

Abstract

BACKGROUND: Thrombosis of hepatic artery anastomosis (HAT) after liver transplantation is a catastrophic and dreaded complication. Early identification of HAT can salvage the situation. To monitor the anastomosis, conventional daily transcutaneous Doppler is performed. However, it has disadvantages of being noncontinuous, operator-dependent and technically difficult. Implantable Doppler probes wrapped around the anastomosed vessel giving continuous signal may be an important tool; however, very few studies are performed to study its efficacy after intra-abdominal vascular anastomosis, and its role is not clearly established.
METHODS: Patients who underwent deceased donor liver transplant surgery were part of the study. On hepatic arterial anastomosis, implantable Doppler probe was fixed for monitoring. Conventional daily transcutaneous Doppler was also performed and the results were compared.
RESULTS: A total of 40 hepatic arterial anastomoses were studied. The incidence of HAT was 10.53%. For the implantable Doppler probe monitoring, sensitivity and negative predictive value was 100%, whereas specificity was 94.44% and positive predictive value was 66.66% with an overall accuracy of 95%. A mean of 10 h of lead time was gained by implantable Doppler probe monitoring.
CONCLUSION: Our study showed that there was high sensitivity and negative predictive value of implantable Doppler probe monitoring system, which makes it ideal for post-operative vascular anastomoses surveillance monitoring; however, abnormal positive finding on implantable Doppler probe monitoring needs to be confirmed by conventional transcutaneous Doppler. The implantable Doppler probe monitoring, because of its round the clock and continuous nature gives us a good lead time in identifying vascular complication, which translates into graft salvage and reduction in morbidity and mortality.
© 2020 Director General, Armed Forces Medical Services. Published by Elsevier, a division of RELX India Pvt. Ltd.

Entities:  

Keywords:  Hepatic arterial anastomosis; Hepatic artery thrombosis; Implantable Doppler probe; Liver transplantation

Year:  2020        PMID: 34305290      PMCID: PMC8282509          DOI: 10.1016/j.mjafi.2020.03.012

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  13 in total

1.  Eight-year experience of the Cook-Swartz Doppler in free-flap operations: microsurgical and reexploration results with regard to a wide spectrum of surgeries.

Authors:  Ariel Schmulder; Eyal Gur; Arik Zaretski
Journal:  Microsurgery       Date:  2011-01       Impact factor: 2.425

Review 2.  Vascular complications following liver transplantation: A literature review of advances in 2015.

Authors:  Tullio Piardi; Martin Lhuaire; Onorina Bruno; Riccardo Memeo; Patrick Pessaux; Reza Kianmanesh; Daniele Sommacale
Journal:  World J Hepatol       Date:  2016-01-08

3.  Implantable venous Doppler monitoring in head and neck free flap reconstruction increases the salvage rate.

Authors:  Keyianoosh Z Paydar; Scott L Hansen; David S Chang; William Y Hoffman; Pablo Leon
Journal:  Plast Reconstr Surg       Date:  2010-04       Impact factor: 4.730

4.  Monitoring buried free flaps: limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test.

Authors:  Jason J Rosenberg; Bruno D Fornage; Pierre M Chevray
Journal:  Plast Reconstr Surg       Date:  2006-07       Impact factor: 4.730

5.  Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study.

Authors:  W M Swartz; N F Jones; L Cherup; A Klein
Journal:  Plast Reconstr Surg       Date:  1988-02       Impact factor: 4.730

6.  Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.

Authors:  Edward I Chang; Amir Ibrahim; Hong Zhang; Jun Liu; Alexander T Nguyen; Gregory P Reece; Peirong Yu
Journal:  Plast Reconstr Surg       Date:  2016-03       Impact factor: 4.730

7.  Uni- and multi-variate analysis of risk factors for early and late hepatic artery thrombosis after liver transplantation.

Authors:  C K Oh; S J Pelletier; R G Sawyer; A R Dacus; C S McCullough; T L Pruett; H A Sanfey
Journal:  Transplantation       Date:  2001-03-27       Impact factor: 4.939

8.  Implantable continuous Doppler monitoring device for detection of hepatic artery thrombosis after liver transplantation.

Authors:  Koert P de Jong; Jasper Bekker; Stijn van Laarhoven; Sven Ploem; Patrick F van Rheenen; Marcel J I J Albers; Christian S van der Hilst; Henk Groen
Journal:  Transplantation       Date:  2012-11-15       Impact factor: 4.939

Review 9.  US of liver transplants: normal and abnormal.

Authors:  Jane D Crossin; Derek Muradali; Stephanie R Wilson
Journal:  Radiographics       Date:  2003 Sep-Oct       Impact factor: 5.333

Review 10.  Early hepatic artery thrombosis after liver transplantation: a systematic review of the incidence, outcome and risk factors.

Authors:  J Bekker; S Ploem; K P de Jong
Journal:  Am J Transplant       Date:  2009-03-02       Impact factor: 8.086

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.